Operation Manual

HA<O>
Sk1
/
Sk2
Owners Manual
110
MIDI
In this mode, you make the basic MIDI settings and the memory
dump operation.
uMIDI TEMPLATE
MIDI TEMPLATE
is mode allows common MIDI setups to be recalled.
By selecting the use with the [][] buttons and pressing the
[ENTER] button, the typical settings are called.
e SK1 and the SK2 have different functions, so the MIDI
templates are also different. See “MIDI TEMPLATE” in the
Appendix (P. 132) for details of each MIDI template.
uMASTER
MIDI IN
is is for switching the MIDI jack function.
LOWER
The received MIDI data sounds the LOWER part and are re-sent
to the LOWER channel (#13) of the MIDI OUT jack, regardless of
the settings of the MIDI channel.
PEDAL
The received MIDI data sounds the PEDAL part and are re-sent to
the PEDAL channel (#14), regardless of the setting of the settings
of the MIDI channel.
LOW + PED
The received MIDI data sounds the LOWER and the PEDAL parts
in accordance with the MIDI channel settings and are re-sent to
the LOWER (#13) and the PEDAL (#14) parts.
SEQUENCE
The received MIDI data sounds the UPPER, LOWER and PEDAL
parts in accordance with the MIDI channel settings. They are not
re-sent.
EXVOICE
The received MIDI data sounds the Extra Voice section regardless
of the MIDI channel settings. They are not re-sent.
LOCAL
is switches the Local Control ON/OFF.
When switched ON, the keyboard(s) and the internal sound
engine are connected. When OFF, the keyboard(s) and the
sound engine are disconnected no sound is played.
You can use this keyboard as two different equipment; the
MIDI keyboard and the sound module at the same time.
NRPN
is switches the NRPN (Non-Registered Parameter Number)
ON/OFF.
On this keyboard it is used for transmitting the messages such
as the Drawbar Fold Back or the Leslie ON. e NRPN is
transmitted through the UPPER channel.
When switched ON, it is transmitted. When OFF, not trans-
mitted.
LESLIE
is is for controlling how to send Leslie Parameters. e Leslie
Parameters sent on UPPER Channel.
SK:
The Leslie Parameters will be sent out on this keyboard original
NRPN address and data.
21:
The Leslie Parameters will be sent out for Leslie 21 series NRPN
address and data.
When the Cabinet Number is selected (i.e. by Patch), the param-
eters are sent out also.
NOTE: This parameter will changed automatically when the Leslie
speaker is connected / disconnected.
PROGRAM CHANGE
is switches the transmission of the program change ON/
OFF. When ON, transmitted. When OFF, not transmitted.
DRAWBAR REGISTRATION
is switches the transmission of the Drawbar registration ON/
OFF. When ON, transmitted. When OFF, not transmitted.
EXTERNAL ZONE
is switches the transmission of the external zones as a whole
ON/OFF. When ON, transmitted. When OFF, not transmit-
ted.
DEVICE ID
is sets the Device ID when transmitting the system exclusive
messages such as the Memory Dump (#11, 12). For example,
To locate this mode:
See “Function mode” (P. 68) for operation details.
MENU/
EXIT
ENTER
SK1’s
SK2’s