System Exclusive Message
Mode Setting Exclusive Message
Full Parameters Reset (Rx. only)
F0 System Exclusive
55 SUZUKI ID
dd Device ID
42
Model ID for DT1
12
Command: DT1
40
Address MSB
00
Address
7F
Address LSB
7F Reset
42 Check Sum
F7
End of Exclusive
NRPN Switch
F0 System Exclusive
55
SUZUKI ID
dd
Device ID
10
Model ID MSB
19
Model ID LSB
02
Command: NRPN Sw.
[DATA] 00h=Off, 7Fh=On
F7
End Of Exclusive
When this device receives this message, switch
Tx&Rx NRPN in Control channel.
Data Set (Rx. only)
F0
System Exclusive
55
SUZUKI ID
dd
Device ID
10
Model ID MSB
19
Model ID LSB
13 Command: Data Set
aa Address MSB
bb Address
cc Address LSB
[DATA] Data (Flexible bytes)
F7
End Of Exclusive
Identity Reply (Tx. only)
F0
System Exclusive
7E
Universal non real-time
dd
Device ID
06
Sub ID #1
02 Sub ID #2
55 SUZUKI ID
00 10 Device Family code
00 19 Device Family number
00 00
00 00
F7 End Of Exclusive
When Identity Request is received, Identity Reply
will be transmitted.
Identity Request (Rx. only)
F0 System Exclusive
7E Universal non real-time
dd Device ID
06 Sub ID #1
01
Sub ID #2
F7
End Of Exclusive
Current Dump/Global Dump
1.Each Packet
F0
System Exclusive
55
SUZUKI ID
dd Device ID
10 Model ID MSB
19
Model ID LSB
11
Command: Data Packet
[TYPE]
Data Type
02h= All Data Dump
07h= Combi. Temp. Dump
08h= Lower Temp. Dump
09h= Global Dump
0Ah= System Dump
[PNH] Packet Number MSB
[PNL] Packet Number LSB
[DATA]
128 Bytes Data
256 Bytes nibblized ASCII
ex: 7Eh = 37h, 45h
[CHD] Check Digit
Lower 7 bits of XOR [DATA]
F7
End of Exclusive
2.Acknowledge
F0
System Exclusive
55
SUZUKI ID
dd Device ID
10 Model ID MSB
19
Model ID LSB
14
Command: Acknowledge
[TYPE]
Data Type
[AK] Result: 00h=OK
05h=Check Digit Error
06h=Receive Protected
[PNH]
Packet Number MSB
[PNL]
Packet Number LSB
F7
End of Exclusive
3. # of Packets
All Data Dump: 709
Combi. Temp. Dump: 3
Lower Temp. Dump: 2
Global Dump: 3
System Dump: 1
Dump Request (Rx. only)
F0 System Exclusive
55 SUZUKI ID
dd
Device ID
10
Model ID MSB
19
Model ID LSB
12 Command: Dump Request
[TYPE] Data Type
02h= All Data Dump
07h= Combi. Temp. Dump
08h= Lower Temp. Dump
09h= Global Dump
0Ah= System Dump
F7
End Of Exclusive