Full Product Manual

7
HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
Assembly - Standard Ceiling Mount
Routing the wires
Assembling the fan
Preparing for mounting
Loosen, but do not remove, the 2 setscrews (PP) on the col-
lar on top of the motor housing (D).
Align the holes at the bottom of the downrod (B) with the
holes in the collar on top of the motor housing (D).
Carefully insert the hanger pin (CC) through the holes in the
collar and downrod (B). Be careful not to jam the hanger pin
(CC) against the wiring inside the downrod (B).
Insert the locking pin (DD) through the hole near the end of
the hanger pin (CC) until it snaps into its locked position.
Re-tighten the 2 setscrews (PP) on the collar on top of the
motor housing (D).
Remove the mounting plate (A) from the canopy (C) by
loosening the four screws on the top of the canopy (C).
Remove the two non-slotted screws (WW), and loosen the
slotted screws. This will enable you to remove the mounting
bracket (A).
Route the wires exiting the top of the fan motor (D)
through the canopy (C) and then through the ball/
downrod assembly (B).
Make sure the slot openings are on top and route the
wires through the canopy (C) and then through the
ball/downrod assembly (B).
2
3
1
C
A
WW
C
B
D
C
B
D
CC
DD
PP
WARNING: Failure to properly install the locking pin could
result in the fan becoming loose and possibly falling.