Room
temperature
charge
retention
capacity
常温荷电保
持能力
After fully charging in accordance with standard
charging mode, the battery is stored for 28 days under
23±5. Then, under 23±2, it is discharged to 3.0V
at 0.2C. Recording discharge time T1. Then, the battery
was filled in the standard charging mode. Under
23±2, the battery was discharged from 0.2C to
3.0v. Recording discharge time T2. Checking battery
appearance.
电池按照标准充电模式充满电后,电池在 23±5℃条件下,
开路搁 28 天;在环境温度 23℃±2℃下,以 0.2 C5
电至 3.0V,记录放电时 T1;然后再将电池按照标准充
环境温度 23±2,以 0.2 C5
3.0V,记录放电时间 T2,检查电池外观.
T14.25h,
T24.5h
No swelling or leakage.
电池不膨胀、不渗漏。
High
temperature
charge
retention
capacity
高温荷电保
持能力
After fully charging in accordance with standard charging
mode, it is stored in the oven under 45
±2
for 7 days.
The battery is removed out to be put aside for 2 hours, then
is discharged at 0.2C5 to the cut-off voltage of 3.0v.
电池按照准充模式充电后,放 45±2的烘中存
7 天;从恒温箱中取出电池恢 2 时,然后以 0.2C5 放电
至终止电压 3.0V
Discharge time ≥4.5h, swelling rate
5%. No swelling or leakage.
放电时间≥4.5h,电池厚度变化率
5%检查电池外观电池不膨胀
不渗漏。
5 Environmental performance 环境性能
测试项目
测试方法 Method
检验标准 Criteria
Constant
humidity
and heat
performance
恒定湿热性
After standard charging, the battery is put into a constant humidity box
with a temperature of 40±2 and a relative humidity of 90%~95% to be
stored for 48h. The battery is removed and stored for 2 hours at an
ambient temperature of 23±2 to check its appearance. Then it is
discharged at a current of 0.2
A
until reaching cut-off voltage of 3.0V
电池准充放入温度 40±2相对湿度90%~95%的恒湿
箱中搁置 48h,将电池取出在 23℃±2℃的环境温度下搁置 2 小时,
检查电池外观,然后以 0.2C5 流放电至终止电压 3.0V
The discharge time of
residual capacity shall be
≥4.5h, swelling rate≤ 5%.
No swelling or leakage.
剩余容量放电时间≥4.5h,电
池厚度变化率5%电池不膨
胀、不渗漏;
ESD test
ESD 测试
After battery standard charging, 8KV is used to conduct contact
discharge at the battery. Battery is continuously discharge for 10 times,
with an interval of 1s. 12KV is used to conduct air discharge on the
weak insulation position of the battery. Battery is continuously discharge
for 10 times, with an interval of 1s.电池标准充电后,使用 8KV 对电池
的每个金属接触点进行接触放电;连续进行 10 次放电,每次放电间
隔时间为 1s。继续使 15KV 电池较薄弱的绝位置进行空气放
电;连续进 10 次放电,每次放电间隔时间为 1s
Battery has no abnormality
and the electrical
performance is normal.
要求电池无异常,电性能正