Outdoor Ceiling Fan User Manual

4.
Hanging the Fan
REMEMBER to turn off the power. Follow the
steps below to hang your fan properly. NOTE:
This ceiling fan is supplied with two types of
hanging assemblies; the standard ceiling
installation using the downrod with ball and
socket mounting and the "flushmount"
installation. The "flushmount" installation is
recommended in rooms with less than 8-foot
ceilings or in areas where additional space is
desired from the floor to the fan blades. When
using the standard 4 1/2" downrod, the
distance from the ceiling to the bottom of the
fan blades will be approximately 12 1/2
inches. The "flushmount" installation reduce
this distance to 8-inches. Once you have
selected which mounting system you will use,
proceed with the following instructions. Where
necessary, each section of the instructions will
note the different procedures to follow for the
two types of mounting.
STANDARD CEILING INSTALLATION
1. Remove the canopy ring from the canopy.
(Fig. 5)
2. Remove the hanger bracket from the
canopy by loosening the four screws on the
top of the canopy. Remove the two non-
slotted screws and loosen the slotted
screws. This will enable you to remove the
hanger bracket. (Fig. 5)
3. Pass the 120-volt supply wires through the
center hole in the ceiling hanger bracket as
shown in Fig. 6.
4. Secure the hanger bracket to the ceiling
outlet box using screws and lock washers
included with your outlet box. (Fig. 6)
5. Remove the hanger pin, lock pin and set
screws from the top of the motor assembly.
6. Route wires exiting from the top of the fan
motor through the canopy ring. Make sure the
widest edge of the canopy ring are on top.
Route the wires through the canopy and then
through the ball/downrod assembly (Fig. 7).
7. Align the holes at the bottom of the downrod
with the holes in the collar on top of the motor
housing (Fig. 7). Carefully insert the hanger pin
through the holes in the collar and downrod. Be
careful not to jam the pin against the wiring
inside the downrod. Insert the locking pin
through the hole in locked position, as noted in
the circle inset of Figure 7.
8. Tighten two set screws on top of the fan
motor firmly. (Fig. 7)
9. Place the downrod ball into the hanger
bracket socket. (Fig. 8)
Figure 5
Figure 6
Ceiling
mounting
bracket
Ceiling
canopy
Screws
Canopy
ring
Tab
Mounting screws
(supplied with
electrical box)
UL Listed
electrical box
Hanger
bracket
WARNING
FAILURE TO PROPERLY INSTALL
LOCKING PIN AS NOTED IN STEP 7
COULD RESULT IN FAN LOOSENING
AND POSSIBLY FALLING.