Instructions / Assembly

6
Figure 8
Groove
Tab
WARNING
THE TAB IN THE RING MUST REST IN THE
GROOVE OF THE HANGER BALL AS FIGURE 8.
FAILURE TO PROPERLY SEAT THE TAB IN
THE GROOVE COULD CAUSE DAMAGE TO
WIRING.
Figure 7
Ceiling
Mounting
Bracket
120V
Wires
Washers
Tab
UL Listed
Outlet Box
Posts in the
Outlet Box
Mounting
Screws
(Supplied
with Electrical Box)
Figure 9
Safety Cable
Ceiling
Mounting
Bracket
Installing Fan to the
Electrical Box
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR OTHER PERSONAL INJURY.
MOUNT FAN ONLY TO AN OUTLET BOX OR
SUPPORTING SYSTEM MARKED ACCEPTABLE
FOR FAN SUPPORT AND USE THE MOUNTING
SCREWS PROVIDED WITH THE OUTLET BOX.
WARNING
Pass the 120-volt supply wires through the
center hole in the ceiling mounting bracket as
shown in Figure 7.
Install the ceiling mounting bracket to the
outlet box; be sure to align the holes in the
hanger bracket with the post holes in the outlet
box and secure with screws and washers
provided by the outlet box. (Fig. 7)
Security tighten the two mounting screws.
Carefully lift the fan assembly up to the ceiling
mounting bracket and seat the hanger ball in
the mounting bracket socket. Make sure the tab
on the mounting bracket socket is properly
seated in the groove in the hanger ball (Figure
8). This will help to balance the ceiling fan.
Secure the safety cable to the building structure
as shown in Figure 9.
1.
2.
3.
4.
5.