Instructions / Assembly

6
Figure 9
Figure 10
Figure 11
Receiver
Ceiling
Mounting
Bracket
Frequency Switch
Making the Electrical
Connections
WARNING
TO AVOID POSSIBLE ELECTRICAL SHOCK, BE
SURE ELECTRICITY IS TURNED OFF AT THE
MAIN FUSE BOX BEFORE WIRING.
CAUTION
THE FREQUENCY SWITCHES ON THE RECEIV-
ING UNIT ARE COVERED WITH A RUBBER
COVER, REMOVE THE RUBBER COVER AND
THEN HAVE IT REPLACED AFTER MAKING
ANY CHANGES TO THE FREQUENCY
SWITCHES.
CAUTION
DO NOT USE WITH WALL LIGHT DIMMER
SWITCH. (FIGURE 11)
(Fig. 12) Motor to receiver electrical connec-
tions: Connect the black wire from the fan to
black wire marked "TO MOTOR L". Connect
the white wire from the fan to the white wire
marked "TO MOTOR N" from the receiver.
Connect the blue wire from the fan to the blue
wire marked "For Light" from the receiver.
Secure the wire connections with the plastic
wire connecting nuts provided.
(Figure 12) Receiver to house supply wires
electrical connections: Connect the black (hot)
wire from the ceiling to the black wire marked
"AC in L" from the receiver. Connect the
white(neutral) wire from the ceiling to the
white wire marked "AC in N" from the
receiver. Secure the wire connections with the
plastic wire connecting nuts provided.
(Figure 12) If your outlet box has a ground
wire (green or bare copper) connect it to the fan
ground wires; otherwise connect the hanging
bracket ground wire to the mounting bracket.
Secure the wire connection with a plastic wire
connecting nut provided. After connecting the
wires spread them apart so that the green and
white wires are on one side of the outlet box
and black and blue wires are on the other side.
Carefully tuck the wire connections up into the
outlet box.
2.
3.
4.
Insert the receiver into the mounting bracket
with the flat side of the receiver facing the
ceiling (Figure 10).
1.
If you feel you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
This remote control unit is equipped with 16 code
combinations to prevent possible interference
from or to other remote units. The frequency
switches on your receiver and transmitter have
been preset at the factory. Please recheck to make
sure the switches on the transmitter and the
receiver are set to the same position, any
combination of settings will operate the fan as
long as the transmitter and receiver are set to the
same position (Figure 9).