Item #1002 633 326 Model #AL634-WH USE AND CARE GUIDE SEAPORT 52 IN. CEILING FAN Questions, problems, missing parts? Before returning to the store, call Hampton Bay Customer Service 8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST Saturday 1-855-HD-HAMPTON HAMPTONBAY.COM Visual instruction of how to install this fan: Visit www.homedepot.com and enter either the Item or Model number to find this fan and click the link of visual instruction in the product overview section.
Table of Contents Table of Contents .......................................................... 2 Safety Information ......................................................... 3 Operation ......................................................................16 Pull Chain Operating Instructions .......................................... 16 Reverse Switch Operating Instructions ..................................16 Warranty .........................................................................
Safety Information 1. To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-1999” and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 3. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs (15.9 kg) or less.
Warranty The manufacturer warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a period of lifetime after the date of purchase by the original purchaser. The manufacturer warrants the light kit (excluding any glass), to be free from defects in workmanship and material at the time of shipment from the factory for a period of three years after the date of purchase by the original purchaser.
Pre-Installation (continued) HARDWARE INCLUDED NOTE: Hardware not shown to actual size.
Pre-Installation (continued) PACKAGE CONTENTS A B C D E G F I H J K Part Quantity Part A Description Mounting bracket (preassembled) 1 G Blade 5 B Canopy 1 H Blade arm 5 C Canopy bottom cover (preassembled) 1 I Light kit mounting plate 1 D Hanger ball/downrod assembly 1 J Light kit 1 E Coupling cover 1 K Glass shade/decorative frame assembly 1 F Fan motor assembly 1 6 Description Quantity
Installation MOUNTING OPTIONS NOTE: You may need a longer downrod to maintain proper blade clearance when installing on a steep, sloped ceiling. The maximum angle allowable is 18° away from horizontal. If the canopy (B) touches the hanger ball/downrod assembly (D), then remove the devorative canopy bottom cover (C) and turn the canopy (B) 180° before attaching the canopy (B) to the mounting bracket (A).
Assembly 1 2 Preparing the canopy □ Remove the canopy bottom cover (C) from the canopy (B) by turning the canopy bottom cover (C) counterclockwise. □ Remove the mounting bracket (A) from the canopy (B) by removing the non-slotted canopy mounting screws (BB) from the bottom of the canopy (B) and loosening the slotted canopy mounting screws (BB) a half turn from the screws head. Next, turn the canopy (B) counterclockwise to remove the mounting bracket (A) from the canopy (B).
Assembly — Hanging the Fan 4 5 Attaching the mounting bracket to the electrical box Hanging the fan from the mounting bracket WARNING: To reduce the risk of fire, electric shock or other personal injury, mount the fan only to an outlet box or supporting system marked acceptable for fan support and use the mounting screws provided with the outlet box. □ Pass the 120-volt supply wires through the center hole in the mounting bracket (A).
Assembly — Hanging the Fan (continued) 6a Making the electrical connections WARNING: To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. Hot Neutral Black White Ground conductor WARNING: Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire nuts (except for the ground wire).
Assembly — Hanging the Fan (optional) 6b Single Switch Connections □ 6c Dual Switch Connections □ On a single switch the fan and light can be turned on or off together. Make wire connections as follows, using the wire nuts (AA). Wall switch not included.
Assembly — Hanging the Fan (continued) 7 WARNING: Make sure the tab on the mounting bracket (A) properly sits in the groove in the hanger ball/downrod assembly (D) before attaching the canopy (B) to the mounting bracket (A) by turning the canopy housing until it drops into place. □ Make sure connections are neatly tucked in the ceiling outlet box (MM).
Assembly — Attaching the Fan Blades 9 Attaching the blades to the blade arms Fastening the blade assemblies to the motor 10 □ Attach the blades (G) to the blade arms (H) using the three blade attachment screws and rubber washers (CC). Start a screw and rubber washer (CC) into the blade arm (H), but do not tighten. □ Repeat for the two remaining blade attachment screws and rubber washers (CC). □ Tighten each screw securely starting with the center screw. Make sure the blade (G) is straight.
Assembly — Installing the Light Kit 11 Attaching the light kit mounting plate to the mounting ring □ Remove one of the three light kit mounting plate screws (HH) from the mounting ring (QQ) and loosen the other two screws. (Do not remove.) □ Place the key holes in the light kit mounting plate (I) over the two screws (HH) previously loosened from the mounting ring (QQ). Turn the light kit mounting plate (I) until the light kit mounting plate (I) locks in place at the narrow section of the key holes.
Assembly — Installing the Light Kit (continued) 13 Installing the light bulbs and glass shade/decorative frame assembly F CAUTION: Before starting installation, disconnect the power by turning off the circuit breaker or removing the fuse at the fuse box. Turning power off using the fan switch is not sufficient to prevent electric shock. □ Install the 9W LED bulb (KK) (included).
Operation PULL CHAIN OPERATING INSTRUCTIONS Install two pull chains and fobs (LL) onto the pull chains located in the light kit (J). Turn on the power and check the operation of the fan. The pull chain controls the fan speed as follows: 1 pull - High, 2 pulls - Medium, 3 pulls - Low, and 4 pulls - Off. Speed settings for warm or cool weather depend on factors such as the room size, ceiling height, and numbers of fans. To turn the light kit on or off, pull the chain that is attached to the light kit (J).
Care and Cleaning Do □ Do not Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure. Because of the fan’s natural movement, some connections may become loose over time. It is not necessary to remove the fan from the ceiling. □ Clean your fan periodically. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer to minimize discoloration or tarnishing.
Troubleshooting (continued) Problem Solution Verify that all blades and blade bracket screws are secure (most fan wobble problems are caused by loose parts). Once the fan is properly installed, run the ceiling fan for 10 minutes to let the fan self-adjust. If wobble occurs after running the fan for 10 minutes, verify blade level using the following process: The fan wobbles.
Service Parts A H AA II I BB JJ B C CC D E DD J F KK EE LL K FF GG G HH Description Part Description A Mounting bracket (preassembled) AA B Canopy BB Canopy mounting screw (preassembled) C Canopy bottom cover (preassembled) CC D Hanger ball/downrod assembly DD Blade arm screw and lock washer (preassembled) E Coupling cover EE Clevis pin (preassembled) F Fan motor assembly FF Cotter pin (preassembled) Part Plastic wire nut Blade attachment screw and rubber washer G
Questions, problems, missing parts? Before returning to the store, call Hampton Bay Customer Service 8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST Saturday 1-855-HD-HAMPTON HAMPTONBAY.COM Retain this manual for future use.