Check that all blade and blade bracket screws
are secure.
Most fan wobble problems are caused when
blade levels are unequal. Check this level by
selecting a point on the ceiling above the tip of
one of the blades. Measure from a point on the
center of each blade to the point on the ceiling.
Measure this distance as shown in Figure 16.
Rotate the fan until the next blade is positioned
for measurement. Repeat for each blade.
Measurements deviation should be within 1/8˝.
Run the fan for 10 Minutes.
Use the enclosed Blade Balancing Kit if the
blade wobble is still noticeable.
1.
2.
3.
The following procedure should correct most fan
wobble. Check after each step.
Figure 16
Touching Ceiling
Figure 17
Attaching the Mounting
Plate
Install the mounting plate to the mounting ring
with the 3 screws previously removed from the
motor support plate. Be sure to tighten all
screws. (Fig. 17)
1.
Mounting Ring
Screws
Mounting Plate
Blade Balancing
(if fan wobble is present after fan is
completely assembled)