Installation Guide

10
Installation - Existing Construction (continued)
7
Installing the housing
Pull the house wires through the wire cover hole (1).
Pull the 4 in. circular duct (not provided) through the
housing.
Install the housing (A) to the joist using one of the following
two methods:
If spacing between the joists is 12 in., secure the
bottom of the housing (A) to the bottom of the joists
using screws (C).
If spacing between the joists is greater than 12 in.,
secure either side of the inside of the housing to the
joists using screws (C). The left side of the inside
housing (A) is shown in the illustration as an example.
1
C
C
A
A
8
Connecting the wires
Using the quick connector, secure 120V AC house wiring
from the wall switch to the fan as shown in the wiring
diagram on page 4. 14 AWG is the minimum requirement
for branch circuit wiring.
Carefully push the connected wires back into the wiring
box housing.
CAUTION: If the electrical wires do not match the colors
listed, you must determine what each house wire represents
before connecting. You may need to consult an electrical
contractor to determine safely.
9
Reinstalling the junction box
Reinstall the junction box (1) into the housing using the
previously-removed screw (2).
2
1