Use and Care Manual

LINE VOLTAGE FLEXIBLE TRACK SYSTEM
INSTRUCTION MANUAL
Please read carefully and save these instructions, as you may need them at a later date.
SAFETY
WARNING: RISK OF ELECTRIC SHOCK
Disconnect the electrical supply circuit before installing light f
ixture
.
GENERAL
All electrical connections must be in accordance with local codes, ordinances or national electrical codes. If you are unfamiliar
with methods of installing electrical wiring, secure the services of a qualified electrician. Before starting installation, disconnect
the power by turning off the circuit breaker or removing the fuse at the fuse box.
INSTALLATION INSTRUCTIONS
CAUTION
: MAKE SURE POWER IS TURNED OFF AT THE ELECTRICAL PANEL BOX BEFORE BEGINNING YOUR
INSTALLATION. TURNING POWER OF
F AT WALL SWITCH IS NOT SUFFICIENT TO PREVENT ELECTRICAL SHOCK
.
GENERAL
1.
Be sure to read these installation instructions and review the diagrams thoroughly before installing the light fixture.
2.
All electrical connections must be in accordance with local codes and the National Electrical Code. If you are unfamiliar
with methods of installing electrical wiring, secure the services of a qualified licensed electrician.
3.
These fixtures are intended to be mounted to a 4
square x 2 1/8 deep metal octagon outlet box. The box must be
directly supported by the building structure.
4.
Before starting the installation, disconnect the power by turning off the circuit breaker or by removing the appropriate fuse
at the fuse box. Turning the power off using the light switch is n ot sufficient to prevent electrical shock.
Note:
The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and
situations that may occur. It must be understood that common sense, caution and care are factors that cannot be built into
any product. These factors must be supplied by the person(s
) caring
for
, installing
and operating the fixture.
IMPORTANT SAFETY INSTRUCTIONS
1.
Read all instructions.
2.
Do not install this lighting system in a damp or wet loca
tion.
3.
Before energizing make sure that the light
ing
system is clear of all material which could cause a direct short and check all
electrical connections to make sure they are tight.
4.
CAUTION
Hot surface, keep away from curtains and other combustible mate
rials.
5.
Lighted lamp is
hot!
Do not touch lamp at any time. Use a soft cloth or relamping tools (see diagram), Oil from skin may
damage lamp.
Turn off power and allow
bulbs
to cool before replacing.
6.
Lamp gets
hot
quickly!
Contact only switch or plug when tu
rning on. Do not touch hot lamp lens.
7.
Do not conceal or extend bus
-
bar conductors through a building wall.
8.
Do not install any part of this system (TRACK) less tha
n
7 feet (2.2m) above floor.
9.
To reduce the risk of fire and burns, do not install this lighting system where
non
insulated open bus-
bar conductors can be
shorted or contact any conductive metals.
10.
To reduce the risk of fire and overheating, make sure all connections are tight.
11.
Do not install any l
amps
closer than 6 inches (15.25cm) f
r
om any curtain
or similar combustible material.
12.
Turn off electrical power before modifying the light system in anyway.
13.
Use minimum 20
spacing between stanchions when using
7
stanchions
.
14.
For use with EC series line
voltage
flexible track system only.
Do not cut any tra
ck sections.
15.
CAUTION
To reduce the risk of a burn during relamping, remove from the track before relamping.
16.
This track system is to be supplied by a single branch 120 volt circuit.
17.
Disconnect electrical power before adding to or changing the configuratio
n of the track.
READ AND SAVE THESE INSTRUCTIONS
UNPACK THE FIXTURE
Parts List:
Check the contents to be sure everything is included
,
12
' flexible track , one power canopy, one canopy mounting
bracket,
7
stanchions,
7
support stems,
7
track mounting brack
ets, and two track end caps.
Tools Needed:
Slotted screwdriver, Adjustable wrench, Electrical Hand drill, Step ladder, Wire cutters, Wiring supplies as
required by electrical code.
ELECTRICAL CONNECTIONS (for all models)
Required Supply Circuit: 120V
, 60H
z
Connect the white wire(s) from the fixture to the white wire of the supply circuit. Connect the black wire(s) from the fixture to the
black wire of the supply circuit. Connect the green
or
bare copper wire to the ground
wire
of the supply circuit
. U
se U
L/CSA
listed wire connectors suitable for the size type, and number of conductors. No loose strands or loose wires should be present
.
Secure wire connectors with UL/CSA listed electrical tape.
HOW TO INSTALL:
INSTALL THE CANOPY ( AS SHOWN IN DIAGRAM)
1.
Turn off the main power.
2.
Install mounting bracket to existing outlet box with
screws.
3.
Pull wires through mounting bracket.
A
.
Make ELECTRICAL CONNECTIONS as directed
above.
B
.
Carefully tuck connected wires back into the outlet
box.
4. Secure
Outlet Box Canopy to the mounting bracket with
the screws
provided.
INSTALL THE LINE VOLTAGE FLEXIBLE TRACK (AS
SHOWN IN DIAGRAM)
CREATE LAYOUT
The line
voltage flexible track kit allows you maximum
flexibility
in creating an attractive lighting system for your
room. The 12
track can be mounted in an infinite
combination of curves and straight runs. The
adjustable
track
heads can be mounted anywhere along
the track run.
INSTALL CEILING SUPPORTS
Method 1:
1.
Remove support stems from stanchions.
2.
Lay
out your track design and mark the p
osition
for
each
stanchion.
Evenly space
stanchions
so that they form
desired pattern. (Use minimum 20
spacing between
stanchions when using
7
stanchions
.)
3.
Drill hole
s
in
the
ceiling at desired stanchion location by
electrical drill. (Note: Please use diameter 6mm drill bit)
4.
Install
enclosed
screw anchors
into drilled hole
s.
5.
Insert the stanchion screws to
s
ecure stanchion
s
to the
ceiling.
6.
Screw
the support stems
into the stanchions
,
and then
install
the
track mounting brackets
to
the
support stems
as
shown
in
the figure.
Method 2:
(As shown in diagram)
1.
Repeat step 1,2 of method 1.
2.
Drill 5/8 inches (16mm) holes in the ce
iling at desired
stanchion location.
3.
Push toggle bolts into the holes drilled into the ceiling
and tighten toggle bolts until
the stanchion and
decorative ring secured.
4.
Repeat step 6 of method1.
INSTALL TRACK
1.
Remove the retaining cap on the power connector
.
2.
Open the power connector cover and a
lign the two slots
of
the
track to
the
two
tabs on the power connector.
3.
Close
the
power connector cover
and
replace the
retaining cap making sure that the connection is
secure.
4.
Remove the retaining cap, open the
track
mounting
bracket
,
and then
insert the flexible track
in
to
the
track
mounting bracket
.
5.
Replace the retaining caps
to
secure
the flexible track
.
INSTALL FIXTURE(sold separately)
1.
Remove the retaining cap
s from the fixtures
.
2.
Align the two
tabs
of
the
track
fix
ture adaptor
to
the
two
slots on the flexible track.
3.
Close
the
fixture
adapter
s
and
replace the
retaining cap
s
making sure that the connection is
secure
Method 2
Decorative ring
Stanchion
Outlet box
Canopy mounting
bracket
Power Canopy
Outlet Box Canopy S
crew
Mounting bracket screw
Wire connector
Power Connector
Retaining cap
Stanchion Ceiling
screw
Stanchion
Support stem
Power Connector
cover
Fixture Adapter
Track Mounting Bracket
Anchor
track
Retaining cap
Fixtur
e(Sold Separately)
End cap
16mm