Installation Guide

11
CIRCUIT DIAGRAM
Electric Wiring Diagram
Disconnect power before servicing.
Any electrical re-wiring of this appliance must be done by a qualified electrician. This wiring must be done in
accordance with local codes and/or in Canada with the current CSA C22.1 Canadian Electrical Code, and for US
installations, the National Electrical Code ANSI/NFPA NO 70.
If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing
locations must be followed.
DANGER
WARNING: Disconnect power before servicing.
HAMPTONBAY.COM
Please contact 855-HD-HAMPTON for further assistance.