Model Number: FG-TUL5PCFCAL-FPSerial Number:
Rated Heat Input : 50,000 BTU/h
Type of Gas : Propane
DANGER
Minimum clearance from combustible constructions: Sides:24in. 610mm. Top:72in. 1829mm.
FOR OUTDOOR USE ONLY.
If stored indoors, detach and leave cylinder outdoors. Do not connect to a remote
gas supply. It is shipped with LP gas orifice. You can find the orifices on the package with LP manual. Pleas
e
follow the instructions package with the orifices for gas conversion.
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or home.
Design Certified by CSA Group
ANS Z21.97/CSA 2.41-2014
Outdoor Decorative Gas Appliances
WARNING: Improper installation, adjustment alteration, service or maintenance can cause injury
before installing or servicing this equipment.
WARNING: Do not store or use gasoline, or other flammable vapors and liquids, in the vicinity of
this or any other appliance.An LP-cylinder not connected foruse shall not be stored in the vicinity of
this or any other appliance.
Gas Supply : 20-lb. LP gas cylinder
Gas Supply Pressure : Max 250 psi
Manifold Pressure : 11 inches
Distributed by Foremost Groups, Inc.
906 Murray Road, East Hanover, NJ 07936, U.S.A.
The instruction manual contains important information necessary for the proper assembly and safe use of the appliance.
Read and follow all warnings and instructions before assembling and using the appliance.
Follow a
ll war
nings and instructions when using the appliance.
If instructionsor parts are missing, contact Foremost Groups Customer Relations Department toll free number at
1-855-390-5474 or 1-800-443-1410 (USA) or 001-855-286-4931 (Int) between the hours of 8:30 am and 5:00 pm EST,
Monday through Friday or fax your request to (973) 428-8026 or email us at customerservice@foremostgroups.com
water column
S
E
D
G
N
R
E
C
T
I
F
I
I
E
D
R
CAUTION: This appliance has been converted to use natural gas.
Propane orifice dia2.09mm, natural gas orifice dia4.18mm.
Rated Heat Input : 50,000 BTU/hr
Type of Gas : Natural gas
Max Gas Supply Pressure : 7 inches water column (1.74kPa)
Min. Gas Supply Pressure : 5 inches water column (1.24kPa)
natural gas hose
13 HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
Operation - Natural Gas Conversion (continued)
4
Disconnecting the propane hose
5
Connecting to the natural gas supply
p
iping system
Connect the natural gas hose with the gas valve by screwing
clockwise tightly.
Plug the natural gas fixture into the natural gas supply piping
system.
6
Stick and cover the conversion label onto the propane rating
plate.
Applying the conversion label to the
propane rating plate
gas valve
natural gas fixture
natural gas hose
natural gas supply piping system
conversion label
propane rating plate
or property damage. Read the installation, operating, and maintenance instructions thoroughly