Safety Information (continued)
WARNING:
The unit is not for use with solid fuel.
The installation must conform with local codes or, in the absence of local codes, ANSIZ223. 1/NFPA54, NFPA58 Natural
Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2.
The heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
Prior to use, check for damaged parts such as hoses, regulators, pilots, or burners.
Inspect the fuel supply connection for signs of leakage (including the hose for the LP models) before each use of the
appliance.
All leak tests should be done with a soapy solution. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away from the
appliance to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the heater.
Clothing or other flammable materials should be not be hung from the heater, or placed on or near the heater.
Any guard or other protective device removed for servicing the heater, must be replaced prior to operating the heater.
Installation and repair should be done by a qualified service person. The heater should be inspected before use and at
least annually by a qualified service person.
More frequent cleaning may be required as necessary. It is imperative that the control compartment, burners, and
circulating air passageways of the heater be kept clean.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
DO NOT OBSTRUCT the combustion process or air ventilation flow.
Keep the ventilation opening(s) of the cylinder enclosure free and clear from debris.
The appliance should be used in a well-ventilated space and not in a building, garage or any other enclosed area.
An appliance may be installed within a shelter if the shelter meets one of the following conditions:
The shelter has walls on all sides, but with no overhead cover.
The shelter is within a partial enclosure which includes side walls. These side walls may be parallel, as in a breezeway,
or at right angles to each other.