Installation Guide

Item #1001 492 715
Model #HD28928
Use and Care Guide
LOW VOLTAGE FLOODLIGHT KIT
Part Description Quantity
A
Lens cover
4
B
20W Halogen T3 Bi-Pin Bulb
4
C
Body
4
D
Adjustment screw
4
E
Connector
4
F
Spike
4
G
120W Transformer
1
H
Wire AWG16 SPT2W 50’
1
I
Plastic anchor
1
J
Screw
1
PACKAGE CONTENTS
Assembly and Installation
1
Attaching and installing the oodlight
WARNING: Never push the xture into the ground by the lamp body (C) or use a
hammer to insert the spike (F) into the ground.
CAUTION: Safe for outdoor operation
WARNING: To reduce the risk of FIRE OR INJURY TO PERSONS:
WARNING: Turn off/unplug and allow to cool before replacing lamp.
WARNING: Lamp gets HOT quickly! Contact only switch/plug when turning on.
Do not touch hot lens, guard or enclosure.
WARNING: Keep the lamp away from materials that may burn.
WARNING: Do not touch the lamp at any time. Use a soft cloth. Oil from skin may
damage the lamp.
WARNING: Do not operate the luminaire tting with a missing or damaged lens
or bulb protector.
Carefully remove the xture from its protective packaging.
Remove the lens cover (A) by turning counterclockwise.
Do not remove the lens from the lens cover.
Insert the bulb (B) into the bulb socket. Use a soft cloth, as oil from
skin may damage the lamp bulb.
Replace the lens cover (A) on the body (C) by turning clockwise.
Adjust the xture’s angle by loosening the adjustment screw (D)
and retightening it.
Ensure the lens points up and
never towards the ground.
WARNING: Install in accordance with all local codes and ordinances.
Only for use with low voltage power units with a maximum output rating of 15V,
300W per secondary.
FOR LANDSCAPE LIGHTING SYSTEMS ONLY. OUTDOOR USE ONLY. THE DEVICE IS
ACCEPTED AS A COMPONENT OF A LANDSCAPE LIGHTING SYSTEM WHERE THE
SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR LOCAL
INSPECTION AUTHORITIES HAVING JURISDICTIO
N.
UL LISTED UNDER MODEL # U201166
Please read and save these instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS
Lighted lamp is HOT!
G
H
I
J
2
Connecting the wires
WARNING: The wire connector (E) contacts have sharp edges for piercing the
main low voltage cable. To avoid injury, do not touch the metal contacts.
CAUTION: The wire from the low voltage power unit shall be 12-16 AWG type
underground low Energy Circuit Cable or SPT2W.
IMPORTANT:
Protect the wiring by routing it in close proximity to the light tting, or next to a
building structure such as a house or deck.
The landscape wire and connector can also be hidden under stone or buried
under grass at a maximum depth of 6” (15.24 cm).
Do not submerge xture in water.
WARNING: Risk of Electric Shock. Install all luminaires 10 ft. (3.05 m) or more
from a pool, spa or fountain.
A
B
C
D
F
E
A
B
C
D
Place the wire connector (E) on opposite sides of the low
voltage cable (H) where the xture will be located.
Align and t the main low voltage cable (H) vertically to the
slot of wire connector (E) as shown.
Press the wire connector (E) together until fully seated and
locked around the cable (H). Pre-set prongs will pierce the
cable insulation and establish contact. Turn on the power unit.
If the light xture does not turn on, repeat previous steps.
Once the clip-on connector (E) is in place, wrap it with
electrical tape for additional protection.
CAUTION BE CAREFUL! THE WIRE STABS ARE VERY SHARP!
After all xtures are installed, turn on the transformer.
E