www.hampton-fire.com H35 Direct Vent Gas Fireplace MODELS: H35-NG1 Natural Gas Owners & Installation Manual H35-LP1 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed ex- What to do if you smell gas: actly, a fire or explosion may result causing property damage, Do not try to light any appliance Do not touch any electrical switch: personal injury or loss of life. do not use any phone in your FOR YOUR SAFETY building.
HAMPTON® Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Hampton® Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The H35 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model H35 has been approved by Warnock Hersey for both safety and efficiency.
TABLE OF CONTENTS Unit Dimensions ............................................................2 SAFETY LABEL Copy of Safety Label .....................................................4 REQUIREMENTS MA Code - CO Detector (for state of Massachusetts only) ..................................5 Conversion Kit to Lower BTU Rating ...........................31 Brick Panel ..................................................................32 Log Set Installation ...................................................
SAFETY LABEL NOTE: Hampton® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. This is a copy of the label that accompanies each Direct Vent Freestanding Gas Stove. We have printed a copy of the contents here for your review. COPY OF SAFETY LABEL For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.
INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation. Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage.
INSTALLATION manufactured home the unit must be bolted down to the floor. 4) This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation. 5) This appliance is Listed for Alcove installations, maintain minimum Alcove clearances as follows, minimum width of 40" (1016mm), a maximum depth of 36" (914mm), and minimum ceiling height of 64" (1626mm) from floor to ceiling.
INSTALLATION LOCATING YOUR GAS STOVE When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation. OPTIONAL FAN INSTALLATION Fan Kit Contains: Qty. 1 1 1 1 Description Fan Speed Controller with nut, and knob. Fan Assembly c/w green wire attached Power cord Plastic locking grommet 1) Remove the Top Control Panel Assembly by removing the three screws. Diagram 1.
INSTALLATION VENTING INTRODUCTION INSTALLATION PRECAUTIONS VENT RESTRICTOR POSITION The Horizontal Termination Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the Direct Vent Freestanding Gas Stoves, H35-NG1, and H35-LP1, have been tested and listed as direct vent heater systems by Warnock Hersey. These venting systems are engineered products that have been designed and tested for use with the H35-NG1, and H35-LP1.
H= G= E= F= A= B= C= D= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) Clearance to window or door that may be opened *(12"/30cm) Clearance to permanently closed window *(min. 12"/30cm) Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of (24"/60cm) from the centerline of the terminal (min. 22"/55cm) check with local code. Clearance to unventilated soffit (min.
INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI.
INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Horizontal Termination Caps Vertical Termination Cap Storm Collar Vinyl Siding Standoff (Optional) Flashing Horizontal Termination Cap Ceiling Firestop Wall Thimble Pipe Length Adj.Pipe Length 11" - 14-5/8" 90o Elbow WARNING: Do not combine venting components from different venting systems. 24" Pipe Length However use of the the AstroCapTM and FPI Riser is acceptable with all systems.
INSTALLATION ROTATING 45O ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS 2) Rotate the elbow 180o 1) Remove all 4 screws that secure the elbow to the unit using a 1/4" magnetic nut driver. 3) Secure the elbow by securing it with the 4 screws.
INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATIONS USING RIGID PIPE The two diagrams show all allowable combinations of straight horizontal termination using Rigid Pipe. Restrictor position "A". Dura-Vent Snorkel Termination Riser Vent Termination Venting Arrangements -Straight Horizontal Termination at a De-Rated BTU The diagrams show all allowable combinations of straight horizontal termination using Rigid Pipe. Restrictor position "A".
INSTALLATION Horizontal Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option A) B) C) D) E) F) 3' 4' 5' 6' 7' 8' V Min. Min. Min. Min. Min. Min. H + H1 2' Max. 3' Max. 4' Max. 5' Max. 6' Max. 8' Max. With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 8 feet total horizontal. Please note minimum 1 foot between 90o elbows is required.
INSTALLATION Vertical Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option A) B) C) D) E) V 1' Min. 2' Min. 3' Min. 4' Min. 5' Min. H 3' Max. 4' Max. 5' Max. 6' Max. 7' Max. V + V1 2' Min. 3' Min. 4' Min. 5' Min. 6' Min. With these options, max. total pipe length is 30 feet with min. of 6 feet total vertical and max. 7 feet total horizontal. Please note min. 1 foot between 90 o elbows is required.
INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. See the Venting Arrangements chart below for minimum and maximum flue lengths. See chart below for minimum distances from roof. Periodically check that the vent is unrestricted.
INSTALLATION DV STOVE HORIZONTAL VENT KIT DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (Part #946-216) includes all the parts needed to install the H35 Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termination Kit" and "Dura-Vent Venting Components" sections. 1) Qty.
INSTALLATION 13) Secure the 4" dia. flex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel). 14) Attach the 45o elbow onto the starter collar by sealing with Mill-Pac and/or high temperature silicone and securing with 3 of the #8 x 1/2" (black) screws. 15) Attach the pipe section to the 45o elbow by sealing with Mill-Pac and/or high temperature silicone and securing with 3 of the #8 x 1/2" screws (black).
INSTALLATION DURA-VENT TERMINATION KIT Planning Your Dura-Vent Installation There are two basic types of Dura-Vent Direct Vent System installations: horizontal termination and vertical termination. Confirm the maximum horizontal run and maximum vertical rise from the diagrams in the "Venting Arrangment" section. When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements.
INSTALLATION DURA-VENT HORIZONTAL INSTALLATIONS Below Grade Snorkel Installation If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Dura-Vent Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure. Diagram 1: Hint: Apply silicone to female end. 1) Set the unit in its desired location.
INSTALLATION Note: a) The horizontal run of vent should have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire. b) The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See diagram in the "External Vent Terminal Locations" section.
INSTALLATION 7) Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic. 8) Install the vertical termination cap by twist locking it. Diagram 10: The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed. This allows for small adjustments.
INSTALLATION CONVERTING CLASS-A METAL CHIMNEY OR MASONRY CHIMNEY TO DIRECT VENT SYSTEM There are two different types of direct vent conversion systems listed below. Follow the appropriate directions for your installation. A) Through an existing factory built metal chimney going through the ceiling: A typical conversion of this type is shown in diagram 1.
INSTALLATION CATHEDRAL CEILINGS Round Support (RDS) & Square Support (SQS) If your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows. 1) Situate the chimney in a convenient location as near as possible to the appliance outlet. Cut and frame a hole in the roof for the support. The sides of this hole must be vertical with 1 1/4" (32mm) clearance.
INSTALLATION AERATION ADJUSTMENT GAS PIPE PRESSURE TESTING 5) The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label. The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude.
INSTALLATION CONVERSION KIT #791-969 FROM NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 4) Each Kit contains one LPG Conversion Kit and one DC Sparker Kit. 9) Turn control knob to the “OFF” position. 10) Remove the black protection cap by hand from the high-low knob (Fig.1). LPG Conversion Kit Contains: Qty.
INSTALLATION 14) Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten. 17) Reverse steps 4) to 2). 4) Attach the DC sparker generator connector to the valve with a screw. 5) Remove the stove’s rear panel by unscrewing the two screws. 6) Attach the ground wire to the grounding stud. 18) Attach clear label "This unit has been converted to LPG" near or on top of the serial # decal. 19) Replace yellow "Natural Gas" label with red "LPG" label.
INSTALLATION 7) Attach the Piezo ignition wire to the DC Sparker. 11) Attach the DC sparker generator wires to the DC sparker. Piezo Ignitor Installation of the DC Sparker for the P90 Units Only: 1) Locate the Piezo Ignitor situated at the side of valve. Piezo Ignitor 12) Install the supplied battery into the DC Sparker Box by opening the battery compartment. 8) Insert both the ground wire and the DC sparker generator wire through the hole of the DC spark heat shield.
INSTALLATION 5) Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit. 9) 13) Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit. Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield. Heat Shield 14) Find a location which is not too hot and is easy to reach for changing the battery. 6) 10) Plug the DC spark generator wires to the DC Sparker.
INSTALLATION CONVERSION KIT TO LOWER BTU RATING NATURAL GAS - KIT #: 740-950 PROPANE - KIT # 740-952 THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Natural Gas Conversion Kit 740-950 Contains: Qty. Part # Description 1 904-240 Burner Orifice #37 (Natural Gas) 1 918-034 Decal "Converted to 30,000 Btu" 1 918-148 Instruction Sheet 5) Unscrew the 2 Rear Log Pins and move to the front hole position. Propane Conversion Kit 740-952 Contains: Qty.
INSTALLATION 10) Adjust Vent restrictor setting: To set the Vent restriction as indicated in the diagram, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws. Unit Btu/h H35 NG 30,000 A 1-3/4" (45mm) H35 LP 28,500 A 1-3/4" (45mm) 4) Before installing the side brick panels, loosen the screws for the brick tabs enough so that you can slide the brick tabs on to the screws easily but that the tabs are secure.
INSTALLATION 4) Place Rear Log A)02-43 on the two pins on the rear log support. 8) Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-43. A)02-43 12) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray. A)02-43 D)02-46 A)02-43 G )0 2- 7 48 F)02 -4 C)02-44 B)02-56 E)02-45 Pins on Rear Log Support Cutout Pin 5) Place the Middle Left Log B)02-56 on the two pins as shown.
INSTALLATION 2) Slide the Optional Side Tile Inset into the side panel, over the spring clip. DOUBLE DOOR INSTALLATION DECORATIVE DOOR GRILL INSTALLATION 1) Secure the Top Door Clip into the Top Front Casting. 1) Hook the Top Clip on the Decorative Door Grill into the top lip of the Front Casting. 3) Repeat for other side. 2) Lift the Decorative Door Grill slightly and drop the Bottom Clips into the bottom lip of the Front Casting. Top Tile Inset 1) Lift the Cast Top off the unit.
INSTALLATION DOOR HINGE REMOVAL 4) Pull all four door hinges out from the sides of the front casting. 1) Remove the cast top by lifting it off of the stove. 5) Use a 7/16" wrench to remove the screws that secure the door hinges. 2) Release the catches on the left and right side of the stove that secure the glass. Remove screws. Release catch by pulling up. 3) Remove the glass by sliding it up and out.
INSTALLATION WIRING DIAGRAMS If any of the original wires as supplied with the appliance must be replaced, it must be replaced with CSA type SEW (200oC) or its equivalent. This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. CAUTION Do not connect the millivolt wall thermostat wires to the 120V wires. WALL THERMOSTAT A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve.
OPERATING INSTRUCTIONS 1) Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location, use Thermostat Wire Table. seen when lighting the unit - the logs have been incorrectly positioned. 7) The unit should never be turned off, and on again without a minimum of a 60 second wait. 2) Connect the wires as per the wiring diagram below.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance. Blower: Hampton® gas appliances use high tech blowers to push heated air farther into the room.
MAINTENANCE GENERAL VENT MAINTENANCE 1) Lift off the Cast Top. If your fan requires maintenance or replacement, access to the fan is through the rear access panel on the back of the unit. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed. Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows: 1) Check the Venting System for corrosion in areas that are exposed to the elements.
MAINTENANCE 11) Carefully lift the burner tray assembly out. 3) Disconnect gas line to stove. 4) Disconnect 3/8" NPT pipe from 90o elbow on valve. 5) Disconnect the two (2) switch wires from valve. Replacing the Fan: Reverse the above steps (1 - 4). Make sure the fan wires and the ground wire are reattached. Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin.
PARTS LIST MAIN ASSEMBLY Part # 1) 2) 3) 4) 5) 6) 8) 9) 10) 11) 942-301** 942-311** 942-321** 942-331** 942-341** 740-931** 942-371** 942-381** 942-391** 942-401** 12) 14) 15) 16) 17) 948-219 740-062 904-209 740-069 740-067 Description Casting - Top Casting - Top Grill Casting - Left Side Casting - Right Side Casting - Front Casting - Double Door Casting - Bottom Skirt Casting - Leg Casting - Insert Plate - Top Casting - Insert Plate Side Hampton® Logo Plate Top Insert Bracket Concealed Hinge Cast Door
PARTS LIST BURNER & LOG ASSEMBLY Part # 740-574/P 740-576/P 910-478 904-689 904-645 910-190 908-672 490-061 910-897 Description 936-170 910-038 910-039 730-041 W840470 * * * * 730-528 Valve Assembly S.I.T. - Natural Gas Valve Assembly S.I.T. - Propane Valve S.I.T. - NG/LP #33 Orifice - N.G.
NOTES Hampton® H35 Direct Vent Freestanding Gas Stove 45
NOTES 46 Hampton® H35 Direct Vent Freestanding Gas Stove
WARRANTY Hampton® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Waterford Product. This warranty is not transferable.
Hampton® fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Hampton® Product. See the inside back cover for details. Register your Hampton® online at http://www.hampton-fire.