Technical Parameter
Instrument size: (W) 160 x (L) 100 x (H) 40mm
Setting value of left shoe: 750KΩ- 100MΩ
Pedal size: 400x 400mm
Setting value of right shoe: 750KΩ- 100MΩ
Adjustable distance of movable support: > 150 mm
Wrist setting value: 750KΩ- 10MΩ
Total weight: 5.6kg
Test accuracy: ± 10%
The range of conductive shoes is 100KΩ- 35MΩ, and the measurement range can
be customized according to the user's requirements
Operation
1. The tester can be operated with 9V battery or AC power supply. Please use a 9V
battery to operate this tester. If the tester is operated with DC power supply, insert
the DC adapter into the small drill hole (9V) at the upper left corner of the tester.
2. During ESD test, as long as you step on the metal plate with your feet, wear a wrist
strap, touch the wiring port, and gently press the metal test button with your fingers,
you will know whether the ESD equipment is qualified at a glance.