3. Wiring the Hub.
The Aperio Hub connects to the Access Control system via Wiegand wiring. The hub
requires 8-24VDC power (250mA). The hub includes three form C relays that can be used
to transmit latch bolt position status, low battery signal and a tamper signal. The hub
connects to the cabinet lock wirelessly.
*Note: The Green LED input is used to grant
access to the cabinet lock. If the Green LED signal
is not available to indicate approved access, the
hub input can be activated by another unlock
signal or relay. Refer to the LED reference card for
any other codes.