User's Manual

500-24050, Rev. B 2
DRAFT
Locate the Hub
NOTE: The hub is not rated for use
in plenum air spaces.
1.
ENSURE the hub is located:
Near the top of a wall or on
the ceiling to reduce potential
for interference.
Within fifty (50) feet of the
lock.
Where there is a maximum of
two interior walls between the
hub and lock.
In the interior lobby, for a
glass entryway.
Mount the Hub
1. MOUNT the hub on a single or
double gang box using the
included adapter plate.
Wire the Hub
NOTE 1: The Green LED and Red LED inputs control feedback that displays at the reader for
approved access (Green) or denied access (Red).
NOTE 2: The hub requires 8–24 VDC power (250 mA).
NOTE 3: The hub includes two form C relays
that can be used to transmit low
battery signal and a tamper signal.
1. ENSURE the Aperio Hub connects
to the Access Control system via
Wiegand wiring.
A
B