User's Manual

Product Components
RF5010 and RF5210: OUTSWING VERSION RF5010 and RF5210: OUTSWING VERSION
Hybrid Electric Strike
Pigtail Connectors (8 pin and 4 pin)
Faceplate (sold separately)
#12-24 Mounting Screws (included with faceplate)
#8-32 Faceplate Screws (included with faceplate)
Trim Enhancer (optional)
Trim Enhancer Screws
Door Position Switch, Press-Fit Magnet
and 10” Connector Cable (2 pin)
1
2
3
4
5
6
7
8
Access Control System
Control Panel and Power Supply
(By others)
8 Pin Connector (Reader Module)
Red (+) Board Power 10 - 14 VDC
Black ( ) Board Power
Green Data 0
White Data 1
Yellow LED/Buzzer
Blue Not Used
Orange Not Used
Brown Not Used
Wire Gauge Diagram
Max. One-way Distance Voltage Drop/100’ Recommended AWG
800’
500’
300’
200’
120’
100’ or less
4 Pin Connector (Strike Module)
Gray (+) Strike Power 12 VDC
Violet ( ) Strike Power
Tan Common
Pink Door Closed and Latch Engaged
2 Pin Connector (Door Position Switch)
Wire plugs into Hybrid Electric Strike
Installation Directions
CAUTION! Before connecting any device at the installation site, verify that there is 12VDC input voltage using a multimeter.
Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage outside the electrical
specifications outlined on page 1 may cause severe damage to the unit and will void the warranty.
1. Prepare door jamb for hybrid electric strike per the appro-
priate template detail (see page 4). Be sure to allow enough
room behind the strike in the cutout to avoid pinching any
wires.
2. Drill a 3/8” hole for the door position switch per the appro-
priate template detail (see page 4). Note that the door position
switch may be positioned as desired, within limits of its 10”
connector. Next, drill a matching 3/8” hole in the door and
install the press-fit magnet so that it comes into contact with
the door position switch.
3. Install mounting tabs (sold separately as P/N 152) when
applicable, using #10-32 screws.
4. Check that the wires running from the host control panel
and/or power supply are correct for the components and
distance (see Wiring Diagram on page 2 and Wire Gauge
Diagram below). Connect the two pigtails provided (8 pin and
4 pin) to these wires. Note that a linear power supply is
recommended.
5. Connect and mount the door position switch, routing its 10”
cable from the door position switch to the hybrid electric
strike.
6. Plug the loose end of the door position switch cable into the
2 pin connector on the bottom of the hybrid electric strike.
7. Connect the wire bundle on the side of the hybrid electric
strike to the pigtails/wire back to the host control panel. Check
any pertinent information from the access control system
installation guide or manual.
Prepare Frame
8. Attach the faceplate to the hybrid electric strike, using the
#8-32 screws provided.
9. Install the trim enhancer on the hybrid electric strike (if
needed to cover any extra space).
10. Install the hybrid electric strike in jamb cutout, using
#12-24 screws provided (or wood screws where necessary).
11. Tighten the #10-32 screws holding the mounting tabs
(when applicable).
Finishing Installing
12. When power is supplied to the hybrid electric strike, the
LED should flash green three times, while the beeper simulta-
neously beeps. The LED should then turn red. This sequence
indicates that the micro-controller is operating properly.
13. Present a Proximity ID card to the reader/antenna. The LED
will turn green, while the beeper beeps once. This indicates
that the card was read successfully.
14. Simultaneously, the keeper should click open. This
indicates that communication between the host and the
hybrid electric strike is operational.
15. For further testing of communication with the host, consult
the manual for the host control panel or the site’s system
administrator.
Testing and Operation
Connect Components and Wiring
12VDC @ 250 mA
0.16
0.25
0.40
0.64
1.01
1.6
12 Gauge
14 Gauge
16 Gauge
18 Gauge
20 Gauge
22 Gauge
Wiring Diagram
2
3
- -
1
2
3
4
5
6
8
7