User Guide
Programming the Scanner 
3-32 
Condensed Data Editor 
♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ 
PROGRAM   END(Exit) 
Family Code Selection  Parameter Selection  Option Code 
Preamble 
 None  
  1-15 characters (use hex value for each character) 
  Maximum 15-character input; scan “FIN” to terminate this selection. 
FIN 
[00-7F], [FIN] 
Postamble 
 None  
  1-15 characters (use hex value for each character) 
Maximum 15-character input; scan “FIN” to terminate this selection. 
FIN 
[00-7F], [FIN] 
Data Length Transmission 
 Disable  
  Enable 2-digits data length transmission 
  If data length exceeds 99, 3-digit data length will be transmitted. 
0 
1 
Code ID Transmission 
  Disable Code ID transmission  
  Enable prefix Code ID transmission 
  Enable suffix Code ID transmission 
  Enable both prefix and suffix Code ID transmission 
0 
1 
2 
3 
Data Pass Control 
  Disable (format match required)  
  Enable (format match not required) 
  If data verifier is false, the original scanned bar code data will be transmitted. 
0 
1 
 The
 Data Editor
 is a very powerful, Artificial-Intelligence based data editing expert system provided specifically for the 3060B/3080B/3220 bar code scanners. 
Through the 
Data Editor
, you can process the scanned data prior to transmitting in many ways, such as: 
Insert, Delete, Match, Verify, Replace, Reorganize
, 
and 
Repeat Transmission
. It also allows you to arrange the transmission of scanned data to any specific format. 
 Due to the resources used by this system, the 
Full-feature Data Editor
 is only supported by 
HHP SET
. Through 
HHP SET
, all settings and configurations can be 
done on-screen, under Windows
®
 95/98/NT environment. 
 A 
Condensed Version Data Editor
 is provided here in the manual and is utilized by scanning the programming bar codes. 
 When Data Pass Control is disabled, all input data must conform to an edited format or the scanner does not transmit the input data to the host. 