User Guide
Table Of Contents
- 2020/3820 User's Guide
- Getting Started
- About This Manual
- Unpacking the System
- Models
- Cordless System: Main Components
- About the Battery
- Base Charge Mode
- Linking Scanner to Base
- Scanner Modes
- Single Scanner Operation
- Multiple Scanner Operation
- Scanner Name
- Scanner Report
- Application Work Groups
- Resetting the Standard Product Default Settings: Current Application Work Group
- Resetting the Standard Product Default Settings: All Application Work Groups
- Using the Scanner with Bluetooth Devices
- Out-of-Range Alarm
- Data Accumulation Mode
- Beeper and LED Sequences and Their Meaning
- Basic Operation of the Cordless System
- Connecting the Base When Powered by Host (Keyboard Wedge)
- Reading Techniques
- Resetting the Standard Product Defaults
- Plug and Play
- Keyboard Wedge Connection
- IBM 4683 Ports 5B, 9B, and 17 Interface
- Connecting the Base with USB
- Connecting the Base with Serial Wedge
- Terminal Interfaces
- Output
- Data Editing
- Data Formatting
- Symbologies
- Introduction
- All Symbologies
- Message Length
- Codabar
- Code 39
- Interleaved 2 of 5
- Code 93
- Straight 2 of 5 Industrial
- Matrix 2 of 5
- Code 11
- Code 128
- Telepen
- UPC A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC E0 and UPC E1
- EAN/JAN 13
- EAN/JAN 8
- MSI
- Plessey Code
- RSS Limited
- RSS Expanded
- EAN.UCC Emulation
- China Post Code
- Korea Post Code
- PosiCode A and B
- Codablock F
- Code 16K
- Code 49
- Interface Keys
- Utilities
- To Add a Test Code I.D. Prefix to All Symbologies
- Reset Scanner
- Show Software Revision
- Show Data Format
- Scanner Report
- Scanner Address
- Base Address
- Resetting the Standard Product Default Settings: Current Application Work Group
- Resetting the Standard Product Default Settings: All Application Work Groups
- Temporary Visual Xpress Configuration
- Visual Xpress
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support

10 - 4 2020/3820 User’s Guide
Example #4: What are the device’s settings for all Codabar selections?
Enter: cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands.
First, the scanner must be put in Manual/Serial Trigger Mode either by scanning
the Manual/Serial Trigger Mode bar code (page 3-4), or by sending the Manual/
Serial Menu Command (page 10-11). Once the scanner is in serial trigger
mode, the trigger is activated and deactivated by sending the following com-
mands:
Activate:SYN T CR
Deactivate:SYN U CR
The scanner scans until a bar code has been read, until the deactivate com-
mand is sent, or until the serial time-out has been reached (see Read Time-Out
(Serial Trigger Mode) on page 3-4 for a description, and the serial command on
page 10-11).