User Guide
Table Of Contents
- 2020/3820 User's Guide
- Getting Started
- About This Manual
- Unpacking the System
- Models
- Cordless System: Main Components
- About the Battery
- Base Charge Mode
- Linking Scanner to Base
- Scanner Modes
- Single Scanner Operation
- Multiple Scanner Operation
- Scanner Name
- Scanner Report
- Application Work Groups
- Resetting the Standard Product Default Settings: Current Application Work Group
- Resetting the Standard Product Default Settings: All Application Work Groups
- Using the Scanner with Bluetooth Devices
- Out-of-Range Alarm
- Data Accumulation Mode
- Beeper and LED Sequences and Their Meaning
- Basic Operation of the Cordless System
- Connecting the Base When Powered by Host (Keyboard Wedge)
- Reading Techniques
- Resetting the Standard Product Defaults
- Plug and Play
- Keyboard Wedge Connection
- IBM 4683 Ports 5B, 9B, and 17 Interface
- Connecting the Base with USB
- Connecting the Base with Serial Wedge
- Terminal Interfaces
- Output
- Data Editing
- Data Formatting
- Symbologies
- Introduction
- All Symbologies
- Message Length
- Codabar
- Code 39
- Interleaved 2 of 5
- Code 93
- Straight 2 of 5 Industrial
- Matrix 2 of 5
- Code 11
- Code 128
- Telepen
- UPC A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC E0 and UPC E1
- EAN/JAN 13
- EAN/JAN 8
- MSI
- Plessey Code
- RSS Limited
- RSS Expanded
- EAN.UCC Emulation
- China Post Code
- Korea Post Code
- PosiCode A and B
- Codablock F
- Code 16K
- Code 49
- Interface Keys
- Utilities
- To Add a Test Code I.D. Prefix to All Symbologies
- Reset Scanner
- Show Software Revision
- Show Data Format
- Scanner Report
- Scanner Address
- Base Address
- Resetting the Standard Product Default Settings: Current Application Work Group
- Resetting the Standard Product Default Settings: All Application Work Groups
- Temporary Visual Xpress Configuration
- Visual Xpress
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support

2 - 12 2020/3820 User’s Guide
The commands to which the scanner responds are listed on page 2-13. The
<ESC> is a 1B in hex. A typical command string is y <ESC> x, where “y” is the
application work group number, “<ESC> x” is the escape command, and the
comma is the terminator
.
Commands may be strung together to create custom response sequences. An
example of a command string is listed below.
0<ESC>4<ESC>5<ESC>6,
The above example will make a scanner in application work group zero beep low,
medium, high.
Once Host ACK is enabled, the system works as follows:
• The scanner reads a code and sends data to the base/host system. No
audible or visual indication is emitted until you receive an escape command.
The scanner read illumination goes out upon a successful read.
• Scanner is suspended until 1) a valid escape string is received from the host
system (via the base) or 2) the scanner “times out.”
• Once condition 1 or 2 above has been met, the scanner is ready to scan
again, and the process repeats.
Time out is indicated by three rapid beeps at the same pitch. A time out occurs
if the source scanner does not receive a valid escape command in 10 seconds.
If a time out occurs, the operator should check the host system to understand
why a response to the scanner was not received.
Host ACK Enable
Host ACK On
* Host ACK Off