User’s Guide 4600rp, 4600g/4600r, 4800i ™ Commercial/Retail/Industrial Area Imager
Disclaimer Hand Held Products, Inc. (“Hand Held Products”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Hand Held Products to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of Hand Held Products.
Note: To maintain compliance with FCC Rules and Regulations, cables connected to this device must be shielded cables. UL Statement UL listed: UL60950-1 for I.T.E. product safety. Canada Industry Canada ICES-003 This Class A digital apparatus complies with Canadian ICES-003 emissions. Conformité à la règlementation canadienne Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada. cUL Statement cUL listed: CSA C22.2 No.60950-1-03 for I.T.E. product safety.
The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal. If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration. You may also contact your supplier for more information on the environmental performances of this product.
The 4800i has a rating of IP54, immunity of windblown dust penetration and splashing water tested to Standard EN60259. CB Scheme Certified to IEC60950-1 I.T.E. Product Safety. Patents Please refer to the product packaging for a list of patents.
Table of Contents Chapter 1 - Getting Started About This Manual ............................................................... 1-1 Unpacking the Imager........................................................... 1-1 Imager Models ...................................................................... 1-2 Imager Identification ............................................................ 1-3 Connecting the Imager with Keyboard Wedge ................... 1-4 Connecting the Imager with USB........................
Wand Emulation ................................................................. 2-14 Data Block Size............................................................ 2-14 Delay Between Blocks ................................................. 2-14 Overall Checksum........................................................ 2-15 Wand Emulation Transmission Rate............................ 2-15 Wand Emulation Polarity............................................. 2-16 Wand Emulation Idle ...............................
Centering............................................................................. 3-12 Decode Search Mode .......................................................... 3-14 Preferred Symbology .......................................................... 3-14 Output Sequence Overview ................................................ 3-16 Output Sequence Editor................................................ 3-19 Require Output Sequence............................................. 3-19 Multiple Symbols........
Chapter 6 - Secondary Interface Secondary RS-232 Connection............................................. 6-2 Secondary Code 39 Wand Emulation................................... 6-2 Wand Emulation Multi Block............................................... 6-3 Delay Between Blocks ................................................... 6-3 Overall Checksum.......................................................... 6-4 Wand Emulation Transmission Rate.............................. 6-4 Wand Emulation Polarity.......
Chapter 7 - Symbologies Message Length Description................................................. 7-2 Codabar Start/Stop Characters....................................... 7-3 Codabar Check Character............................................... 7-3 Codabar Concatenation .................................................. 7-4 Codabar Message Length ............................................... 7-5 Code 39 Start/Stop Characters....................................... 7-6 Code 39 Check Character............
UPC-E0 Check Digit.................................................... 7-23 UPC-E0 Number System ............................................. 7-24 UPC-E0 Addenda......................................................... 7-24 EAN/JAN-13 Check Digit ........................................... 7-25 EAN/JAN-13 Addenda ................................................ 7-26 EAN/JAN-13 Addenda Required................................. 7-26 EAN/JAN-13 Addenda Separator ................................
Data Matrix Message Length ....................................... 7-48 MaxiCode Message Length.......................................... 7-49 Aztec Code Message Length ........................................ 7-50 Aztec Runes.................................................................. 7-50 Chapter 8 - Imaging Commands Single-Use Basis ................................................................... 8-1 Command Syntax..................................................................
Chapter 11 - Utilities To Add a Test Code I.D. Prefix to All Symbologies.......... 11-1 Show Decoder Revision ..................................................... 11-1 Show Engine Revision........................................................ 11-1 Show Scan Driver Revision................................................ 11-2 Show Software Revision..................................................... 11-2 Show Data Format ..............................................................
Chapter 14 - Maintenance Repairs ................................................................................ 14-1 Maintenance........................................................................ 14-1 Cleaning the Device ..................................................... 14-1 Inspecting Cords and Connectors................................. 14-1 Replacing the Interface Cable ...................................... 14-2 Troubleshooting .................................................................
x
1 Getting Started About This Manual This User’s Guide provides installation and programming instructions for the 4000 Series imagers. Product specifications, dimensions, warranty, and customer support information are also included. Hand Held Products barcode imagers are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the barcodes in this guide.
Imager Models The chart below lists the interfaces that can be used with your imager. Refer to Chapter 6 for programming information regarding secondary interfaces.
Imager Identification Compliance Label location Item Number, Serial Number and Revision Information location 4600rp, 4600g/4600r, 4800i User’s Guide 1-3
Connecting the Imager with Keyboard Wedge Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager. An imager can be connected between the keyboard and PC as a “keyboard wedge,” plugged into the serial port, or connected to a portable data terminal in wand emulation or non decoded output mode. The following is an example of a keyboard wedge connection: 1. Turn off power to the terminal/computer. 2. Disconnect the keyboard cable from the back of the terminal/computer. 3.
Connecting the Imager with USB Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager. An imager can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the imager first, then to the computer. 2. Program the imager for a USB interface using the Plug and Play barcodes beginning on page 1-9. 3. The imager beeps. 4. Verify the imager operation by scanning a barcode from the Sample Symbols in the back of this manual.
Connecting the Imager with RS-232 Serial Port Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager. 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the imager. Note: For the imager to work properly, you must have the correct cable for your type of terminal/computer. 3. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 4.
Connecting the Imager with RS-232 Wedge Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager. Your imager uses True and TTL signal levels to wedge into an RS-232 serial network. Use only serial wedge cables to prevent damage to the imager. Refer to RS-232 Baud Rate on page 2-10 to set the baud rate and communications protocol. 1. Turn off power to the computer. 2. Disconnect the existing serial cable from the computer. 3.
9. To set up the serial wedge terminal ID, use the serial terminal ID 050 and follow the instructions on page 2-1. 10. Program the port for data transmission using the barcodes on page 1-12. Programming the Interface - Plug and Play Plug and Play barcodes provide instant imager set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.
USB Connection IBM SurePos Scan one of the following “Plug and Play” codes to program the imager for IBM SurePos (USB Hand Held imager) or IBM SurePos (USB Tabletop imager). Note: After scanning one of these codes, you must power cycle the cash register.
USB PC or Macintosh® Keyboard Scan one of the following codes to program the imager for USB PC Keyboard or USB Macintosh Keyboard. Scanning these codes adds a CR and selects the terminal ID (USB PC Keyboard - 124, USB Macintosh Keyboard - 125). USB Keyboard (PC) USB Keyboard (Mac) USB Japanese Keyboard (PC) USB HID Scan the following code to program the imager for USB HID barcode imagers. Scanning this code changes the terminal ID to 131.
CTS/RTS Emulation On * Off ACK/NAK Mode On * Off RS-232 Serial Port Connection All communication parameters between the imager and terminal must match for correct data transfer through the serial port using RS-232 protocol. Scanning the RS-232 interface barcode programs the imager for an RS-232 interface at 38,400 baud, parity–none, 8 data bits, 1 stop bit, and adds a suffix of a CR LF.
Serial Wedge Data Transmission Port Using the following barcodes, set the port to which you want the scanned data to transmit. Port 1 corresponds to P1 on the output cable and Port 2 corresponds to P2 on the output cable. Choosing Both sends scanned data to P1 and P2. Default = P1. * P1 P2 Both P1 and P2 IBM 4683 Ports 5B, 9B, and 17 Connection Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.
Each of the previous barcodes also programs the following suffixes for each symbology: Symbology EAN-8 EAN-13 UPC-A UPC-E Code 39 Interleaved 2 of 5 Code 128 Suffix 0C 16 0D 0A 00 0A 0B 00 0D 0B 00 0A 0B .
The Wand Emulation Plug & Play (Code 39 Format) barcode below sets the terminal ID to 61. The Wand Emulation Plug & Play Same Code barcode sets the terminal ID to 64. These barcodes also set the Transmission Rate to 25 inches per second, Output Polarity to black high, and Idle State to high. (If you want to change the terminal ID only, without changing any other imager settings, please refer to Wand Emulation Connection on page 2-13.
Reading Techniques The imager has a view finder that projects a bright red or green aiming beam that corresponds to the imager’s horizontal field of view. The aiming beam should be centered over the barcode, but it can be positioned in any direction for a good read. Linear barcode 2D Matrix symbol The aiming beam is smaller when the imager is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit.
1 - 16 4600rp, 4600g/4600r, 4800i User’s Guide
2 Terminal Interfaces Terminal ID If your interface is not covered by a Plug and Play barcode from Chapter 1, then refer to Supported Terminals on page 2-2 through page 2-3, and locate the Terminal ID number for your PC. Scan the Terminal ID barcode below, then scan the numeric barcode(s) from the Programming Chart inside the back cover of this manual to program the imager for your terminal ID. Scan Save to save your selection. For example, an IBM AT terminal has a Terminal ID of 003.
Supported Terminals Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.
Supported Terminals Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.
Keyboard Country Scan the appropriate country code below to program the keyboard for your country.
Keyboard Country (continued) Italy Latin America Netherlands (Dutch) Norway Poland Portugal Romania Russia SCS Slovakia Spain Sweden Switzerland (German) 4600rp, 4600g/4600r, 4800i User’s Guide 2-5
Keyboard Country (continued) Turkey F Turkey Q U.K. Please refer to the Hand Held Products website (www.handheld.com) for complete keyboard country support information and applicable interfaces. If you need to program a keyboard for a country other than one listed above, scan the Program Keyboard Country barcode below, then scan the numeric barcode(s) for the appropriate country from the inside back cover, then the Save barcode.
Shift Lock is used when you normally have the Shift Lock key on (not common to U.S. keyboards). Shift Lock Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off (AT and PS/2 only). This selection can only be used with systems that have an LED which notes the Caps Lock status. Automatic Caps Lock Autocaps via NumLock barcode should be scanned in countries (e.g.
Control + ASCII Mode On: The imager sends key combinations for ASCII control characters for values 00-1F. Windows is the preferred mode. All keyboard country codes are supported. DOS mode is a legacy mode, and it does not support all keyboard country codes. New users should use the Windows mode. Refer to Keyboard Function Relationships, page 10-1 for CTRL+ ASCII Values.
Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters.
RS-232 Baud Rate Baud Rate sends the data from the imager to the terminal at the specified rate. The host terminal must be set for the same baud rate as the imager. Default = 38,400.
RS-232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications which require use of the full ASCII set, select 8 data bits per character. Default = 8. Stop Bits sets the stop bits at 1 or 2. Default = 1. Parity provides a means of checking character bit patterns for validity. Default = None.
RS-232 Receiver Time-Out The unit stays awake to receive data until the RS-232 Receiver Time-Out expires. A manual or serial trigger resets the time-out. When an RS-232 receiver is sleeping, a character may be sent to wake up the receiver and reset the time-out. A transaction on the CTS line will also wake up the receiver. The receiver takes 300 milliseconds to completely come up.
Wand Emulation Connection The Wand Emulation Connection barcodes should be used if you want to change the terminal ID only, without changing any other imager settings. We recommend using Wand Emulation Plug & Play barcodes to program your imager to emulate a wand reader. The Wand Emulation Plug & Play barcodes change other parameters, in addition to changing the terminal ID. Please refer to Connecting the Imager with RS-232 Wedge on page 1-7 for further information.
Wand Emulation Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager. Note: Changing primary wand emulation settings also changes the secondary wand emulation settings (see Secondary Code 39 Wand Emulation on page 6-2). Data Block Size This transmits the data in smaller blocks to prevent buffer overflow. Default = 40. 20 * 40 60 80 Delay Between Blocks This sets the delay time between data blocks. Default = 50ms.
Overall Checksum When this option is turned on, a computed check character is added at the end of the entire message. The check character is the character which when Exclusive-OR’d with every preceding character of the message yields a result of 0x00 (00H). Default = Off. On * Off Wand Emulation Transmission Rate The Transmission Rate is limited by the terminal’s ability to receive data without dropping characters. Default = 25 inches/second.
Wand Emulation Polarity The Polarity can be sent as standard with black bars high, or reversed with white bars high. Default = Black High. * Black High White High Wand Emulation Idle The idle describes the state of the imager when no data is being transmitted. When in Wand Emulation mode, you must set the imager’s idle state to match the idle state for the device to which the imager is connected. Default = Idle High.
3 Output Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On. * On Off Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the imager emits on a good read. Default = Medium for the 4600g/4600r/4600rp; High for the 4800i.
Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the imager emits on a good read. Default = Medium. Low (1600 Hz) * Medium (3250 Hz) High (4200 Hz) Beeper Duration – Good Read The beeper duration codes modify the length of the beep the imager emits on a good read. Default = Normal. * Normal Beep Short Beep LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On.
Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read. The beeps and LED flashes are in sync with one another.
Trigger Modes Manual/Serial Trigger You can activate the imager either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 12-4). When in manual trigger mode, the imager scans until a barcode is read, or until the trigger is released. When in serial mode, the imager scans until a barcode has been read or until the deactivate command is sent.
Note: Manual Trigger, Low Power cannot be used with keyboard wedge applications. Low Power Time-Out Timer Scan the Low Power Time-Out barcode to change the time-out duration (in seconds). Then scan the time-out duration (from 0-300 seconds) from the inside back cover, and Save. Default = 120 seconds. If the unit remains idle during the low power time-out interval, the unit goes into low power mode. Whenever the trigger is enabled, the low power time-out timer is reset.
Note: The imager automatically adjusts the illumination LEDs to the lowest light level possible to maintain a good lock on the Scan Stand symbol. When a symbol is presented, the imager’s light levels adjust to the saved setting (see LED Power Level on page 3-9). This mode requires at least 50 lux of ambient light to operate correctly. Scan Stand Mode Scan Stand Symbol When a unit is in Scan Stand mode, the LEDs shine at the Scan Stand symbol on the base of the stand which tells it to remain idle.
Presentation LED Behavior after Decode When an imager is in presentation mode, the LEDs remain on and continue scanning for a short time after a barcode is decoded. If you wish to turn the LEDs off immediately after a barcode is decoded, scan the LEDs Off barcode, below. Default = LEDs On. * LEDs On LEDs Off Presentation Sensitivity Presentation Sensitivity is a numeric range that increases or decreases the imager's reaction time to barcode presentation.
Hands Free Time-Out The Scan Stand, and Presentation, and Streaming Presentation Modes are referred to as “hands free” modes. If the imager’s trigger is pulled when using a hands free mode, the imager changes to manual trigger mode. You can set the time the imager should remain in manual trigger mode by setting the Hands Free Time-Out. Once the time-out value is reached, (if there have been no further trigger pulls) the imager reverts to the original hands free mode.
User-Specified Reread Delay If you want to set your own length for the reread delay, scan the barcode below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. User-Specified Reread Delay LED Power Level This selection allows you to adjust LED and aimer brightness. Off is used when no illumination is needed. Low is used if low illumination is sufficient. High (the default) is the brightest setting.
Note: This setting does not affect the aimer light. The aiming light can be set using Aimer Mode (page 3-11). * Lights On Lights Off Imager Time-Out Imager Time-Out powers down the imager after the unit has been idle for the specified time. To prevent the imager from powering down, set this time-out to 0. Scan the barcode below, then set the time-out by scanning digits (from 0 999,999 ms) from the inside back cover, then scanning Save. Default = 60,000 ms.
User-Specified Aimer Delay If you want to set your own length for the duration of the delay, scan the barcode below, then set the time-out by scanning digits (0 - 4,000 ms) from the Programming Chart inside the back cover of this manual, then scan Save. Delay Duration Aimer Mode Note: Concurrent is the default for units with 4X00 engines. Interlaced is the default for units with 5X00 engines. Refer to the Show Engine Revision on page 11-1 for information on determining the engine in your unit.
Centering Use Centering to narrow the imager’s field of view to make sure the imager reads only those barcodes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read. (Centering can be used in conjunction with Aimer Delay, page 3-10, for the most error-free operation in applications where multiple codes are spaced closely together.
Scan Centering On, then scan one of the following barcodes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Centering = 40% for Top and Left, 60% for Bottom and Right.
Decode Search Mode There are three selectable decode (scanning) modes: Full Omnidirectional - Searches for barcode features beginning at the center of an image, and searches to the image’s limits. This mode reads all symbologies (including OCR), in any orientation. The Full Omnidirectional search is very thorough which may slow performance time. Note: This search mode is the default setting.
Preferred Symbology classifies each symbology as high priority, low priority, or as an unspecified type. When a low priority symbology is presented, the imager ignores it for a set period of time (see Preferred Symbology Time-out on page 3-16) while it searches for the high priority symbology. If a high priority symbology is located during this period, then that data is read immediately.
Preferred Symbology Time-out Once you have enabled Preferred Symbology and entered the high and low priority symbologies, you must set the time-out period. This is the period of time the imager will search for a high priority barcode after a low priority barcode has been encountered. Scan the barcode below, then set the delay (from 100-3,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 500 ms.
2. Code I.D. On the Symbology Chart on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.
You would set up the sequence editor with the following command line: SEQBLK62999941FF6A999942FF69999943FF The breakdown of the command line is shown below: SEQBLK 62 9999 41 FF 6A 9999 42 FF 69 9999 43 FF sequence editor start command code identifier for Code 39 code length that must match for Code 39, 9999 = all lengths start character match for Code 39, 41h = “A” termination string for first code code identifier for Code 128 code length that must match for Code 128, 9999 = all lengths start character ma
Output Sequence Editor Enter Sequence Default Sequence Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the imager will not transmit the output data to the host device. When it’s On/Not Required, the imager will attempt to get the output data to conform to an edited sequence, but if it cannot, the imager transmits all output data to the host device as is.
Multiple Symbols Note: This feature does not work when the Imager is in Low Power mode. When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the Imager’s trigger. If you press and hold the trigger, aiming the Imager at a series of symbols, it reads unique symbols once, beeping (if turned on) for each read. The imager attempts to find and decode new symbols as long as the trigger is pulled.
Print Weight Print Weight is used to adjust the way the imager reads Matrix symbols. If an imager will be seeing consistently heavily printed matrix symbols, then a print weight of 6 may improve the reading performance. For consistently light printing, a print weight of 2 may help. After scanning the Set Print Weight barcode, set the print weight (from 1-7) by scanning digits from the inside back cover, then scanning Save. Default = 4.
Working Orientation Some barcodes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the imager. Default = Upright.
4 Data Editing Prefix/Suffix Overview When a barcode is scanned, additional information is sent to the host computer along with the barcode data. This group of barcode data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data.
To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-4). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in Appendix A) for the symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4.
To Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2.
Prefix Selections Add Prefix Clear One Prefix Clear All Prefixes Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the imager transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 10-3. When the imager is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted.
Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity. Each delay is composed of a 5 millisecond step. You can program up to 99 steps (of 5 ms each) for a range of 0-495 ms.
User Specified Intercharacter Delay An intercharacter delay of up to 495 milliseconds (in 5 ms steps) may be placed after the transmission of a particular character of scanned data. Scan the Delay Length barcode below, then scan the number of 5 millisecond steps (0-99), and the Save barcode using the Programming Chart inside the back cover of this manual.
Intermessage Delay An intermessage delay of up to 495 milliseconds (in 5 ms steps) may be placed between each scan transmission. Scan the Intermessage Delay barcode below, then scan the number of 5 millisecond steps (0-99), and the Save barcode using the Programming Chart inside the back cover of this manual. 1st Scan Transmission 2nd Scan Transmission Intermessage Delay Intermessage Delay To remove this delay, scan the Intermessage Delay barcode, then set the number of steps to 0.
4-8 4600rp, 4600g/4600r, 4800i User’s Guide
5 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the imager’s output. For example, you can use the Data Format Editor to insert characters at certain points in barcode data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None.
Step 4. Code I.D. In Appendix A, find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual. Step 5. Length Specify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the four digit data length from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050.
F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor position. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4, and nn is the numeric value (00-99) for the number of times it should be sent.) E9 Send all but the last “nn” characters, starting from the current cursor position. Syntax = E9nn (nn is the numeric value (00-99) for the number of characters that will not be sent at the end of the message.
E5 FE EC ED ters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2. Terminates character replacement. Syntax = E5. Compare character in current cursor position to the character “xx.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FExx (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.) Check to make sure there is an ASCII number at the current cursor position.
Data Format Editor Enter Data Format * Default Data Format Clear One Data Format Clear All Data Formats Save Discard Data Formatter When Data Formatter is turned off, the barcode data is output to the host as read (including prefixes and suffixes). Choose one of the following options. Default = Data Formatter On, but Not Required.
Alternate Data Formats Alternate formats allow you “single shot” capability to scan one barcode using a different data format than your primary format. When data formats are programmed (see page 5-1), you must input whether you are programming the primary format, or an alternate format numbered 1, 2, or 3. An alternate format is initiated by scanning one of the 3 alternate format barcodes below.
6 Secondary Interface By switching secondary interface cables, the imager can, for example, communicate with a portable data terminal (secondary interface) in addition to the host terminal (primary interface). Refer to the table below for interfaces supported by your model. Some features don’t apply if the interface is not supported by your model.
You can temporarily disable the secondary interface, but still retain the secondary interface settings in the imager’s memory by scanning the Disable barcode below. To re-enable the secondary interface, scan the Enable barcode. Default =Disable. * Disable Enable Secondary RS-232 Connection All communication parameters between the imager and terminal must match for correct data transfer through the serial port using RS-232 protocol.
The Code 39 Format barcode below sets the terminal ID to 61, and the Same Code Format barcode sets the terminal ID to 64. Wand Emulation Same Code Format Wand Emulation Code 39 Format Wand Emulation Multi Block Note: See "Imager Models" on page 6-1 to determine which interfaces apply to your imager. Note: Changing secondary wand emulation settings also changes the primary wand emulation settings (see Wand Emulation on page 2-14). Delay Between Blocks This sets the delay time between data blocks.
Overall Checksum When this option is turned on, a computed check character is added at the end of the entire message. The check character is the character which when Exclusive-OR’d with every preceding character of the message yields a result of 0x00 (00H). Default = Off. On * Off Wand Emulation Transmission Rate The Transmission Rate is limited by the terminal’s ability to receive data without dropping characters. Default = 25 inches/second.
Wand Emulation Polarity The Polarity can be sent as standard with black bars high, or reversed with white bars high. Default = Black High. * Black High White High Wand Emulation Idle The idle describes the state of the imager when no data is being transmitted. When in Wand Emulation mode, you must set the imager’s idle state to match the idle state for the device to which the imager is connected. Default = Idle High.
Secondary Trigger Mode Manual/Serial Trigger You can activate the imager either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 12-4). When in manual trigger mode, the imager scans until a barcode is read, or until the trigger is released. When in serial mode, the imager scans until a barcode has been read or until the deactivate command is sent.
Low Power Time-Out Timer Scan the Low Power Time-Out barcode to change the time-out duration (in seconds). Then scan the time-out duration (from 0-300 seconds) from the inside back cover, and Save. Default = 120 seconds. If the unit remains idle during the low power time-out interval, the unit goes into low power mode. Whenever the trigger is enabled, the low power time-out timer is reset. Low Power Time-Out Note: This time-out does not begin until the imager time-out setting has expired.
Scan Stand Mode Note: Scan Stand Mode is only available for non-advanced illumination units with software revision 31205480-090 or older. Refer to the Show Software Revision on page 11-2 for information on determining the software in your unit. When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan Stand symbol. (See Scan Stand Symbol that follows.) When a different code is presented, the Imager is triggered to read the new code.
7 Symbologies This programming section contains the following menu selections. Refer to Chapter 12 for settings and defaults.
All Symbologies If you want to decode all the symbologies allowable for your imager, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology. All Symbologies On All Symbologies Off Message Length Description You are able to set the valid reading length of some of the barcode symbologies.
Codabar Codabar * On Off Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.” You can program the imager to read only Codabar barcodes with Modulo 16 check characters. Default = No Check Character.
When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar barcodes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the imager looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character.
Select Require to prevent the imager from decoding a single “D” Codabar symbol without its companion. This selection has no effect on Codabar symbols without Stop/Start D characters. On * Off Require Codabar Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
Code 39 < Default All Code 39 Settings > Code 39 * On Off Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Code 39 Check Character No Check Character indicates that the imager reads and transmits barcode data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 barcodes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate and Transmit, the imager only reads Code 39 barcodes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character.
Code 39 Append This function allows the imager to append the data from several Code 39 barcodes together before transmitting them to the host computer. When this function is enabled, the imager stores those Code 39 barcodes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data. The imager stores the data in the order in which the barcodes are read, deleting the first space from each.
Note: Trioptic Code (page 7-34) must be turned off while scanning Code 32 Pharmaceutical codes. On * Off Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the barcode symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off.
Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting.
When Check Digit is set to Validate and Transmit, the imager only reads Interleaved 2 of 5 barcodes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit Interleaved 2 of 5 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80.
Code 93 < Default All Code 93 Settings > Code 93 * On Off Code 93 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93 Code Page Code pages define the mapping of character codes to characters.
Straight 2 of 5 Industrial Straight 2 of 5 Industrial On * Off Straight 2 of 5 Industrial Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Straight 2 of 5 IATA (Two-Bar Start/Stop) Straight 2 of 5 IATA On * Off Straight 2 of 5 IATA Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Matrix 2 of 5 Matrix 2 of 5 On * Off Matrix 2 of 5 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Code 11 On * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 barcodes. Default = Two Check Digits. One Check Digit * Two Check Digits Code 11 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Code 128 Code 128 * On Off ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood information in a uniform manner. The use of ISBT formats requires a paid license.
Code 128 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 Code Page Code pages define the mapping of character codes to characters.
Telepen Telepen On * Off Telepen Output Using AIM Telepen Output, the imager reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the imager reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output.
UPC-A UPC-A * On Off UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On.
UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-A Addenda Required When Required is scanned, the imager will only read UPC-A barcodes that have addenda. You must then turn on a 2 or 5 digit addenda listed on page 7-21. Default = Not Required.
UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. Default = On. * On Off UPC-E0 UPC-E0 Most U.P.C. barcodes lead with the 0 number system. For these codes, use the UPC-E0 selection. If you need to read codes that lead with the 1 number system, use UPC-E1 (page 7-24). Default = On. * UPC-E0 On UPC-E0 Off UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format.
UPC-E0 Addenda Required When Addenda Required is set to on, the imager will only read UPC-E barcodes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda. When turned off, there is no space. Default = On. * On Off UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
UPC-E0 Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On Off UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-E1 Most U.P.C. barcodes lead with the 0 number system.
EAN/JAN-13 EAN/JAN-13 * On Off EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-13 Addenda Required When Addenda Required is set to on, the imager will only read EAN/JAN-13 barcodes that have addenda. Default = Not Required.
Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code (page 7-22). ISBN Translate This selection causes EAN-13 Bookland symbols to be translated into their equivalent ISBN number format. Default = Off. On * Off EAN/JAN-8 EAN/JAN-8 * On Off EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Addenda Required is set to on, the imager will only read EAN/JAN-8 barcodes that have addenda. Default = Not Required.
MSI MSI On * Off MSI Check Character Different types of check characters are used with MSI barcodes. You can program the imager to read MSI barcodes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate and Transmit, the imager will only read MSI barcodes printed with the specified type check character, and will transmit this character at the end of the scanned data.
MSI Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Plessey Code Plessey Code On * Off Plessey Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information.
GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional * On Off GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited * On Off GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > 4600rp, 4600g/4600r, 4800i User’s Guide 7 - 31
GS1 DataBar Expanded * On Off GS1 DataBar Expanded Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74.
PosiCode PosiCode A and B * On Off You have to have PosiCode A and B on to read any of the PosiCode symbologies. A and B On (No Limited) A and B and Limited A On (Limited B Off) * A and B and Limited B On (Limited A Off) PosiCode Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48.
Trioptic Code Note: If you are going to scan Code 32 Pharmaceutical codes (page 7-8), Trioptic Code must be off. Trioptic Code is used for labeling magnetic storage media. On * Off Codablock F Codablock F On * Off Codablock F Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.
Code 16K Code 16K On * Off Code 16K Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-160. Minimum Default = 1, Maximum Default = 160.
Code 49 Code 49 * On Off Code 49 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81.
PDF417 < Default All PDF417 Settings > PDF417 * On Off PDF417 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.
MicroPDF417 < Default All MicroPDF417 Settings > MicroPDF417 On * Off MicroPDF417 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. Minimum Message Length Maximum Message Length EAN•UCC Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called EAN•UCC Composite symbology.
UPC/EAN Version Scan the UPC/EAN Version On barcode to decode EAN•UCC Composite symbols that have a UPC or EAN linear component. (This does not affect EAN•UCC Composite symbols with a UCC/EAN-128 or GS1linear component. If either of these codes are the linear component, either Code 128 or the correct GS1 code must be enabled.) UPC/EAN Version On * UPC/EAN Version Off EAN•UCC Composite Code Message Length Scan the barcodes below to change the message length.
EAN•UCC Emulation The imager can automatically format the output from any EAN•UCC data carrier to emulate what would be encoded in an equivalent UCC/EAN-128 or GS1 and Composite symbol. EAN•UCC data carriers include UPC-A and UPC-E, EAN13 and EAN-8, ITF-14, UCC/EAN-128, and EAN•UCC GS1 and Composites. Data from 2D symbols such as Aztec Code, Data Matrix, or QR Code, which encode a leading FNC1, also invoke EAN•UCC emulation.
Postal Codes Note: For best performance when reading a postal symbology, all other postal symbologies should be turned off. The following postal codes can only be read by a 2D Imager. 4-CB (4-State Customer Barcode) Note: You may enable the 4-CB (4-State Customer Barcode) if you have firmware with a base number of 31205480. Refer to the Show Software Revision on page 11-2 for information on determining the firmware revision in your unit.
Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data. Transmit Check Digit * Don’t Transmit Check Digit Planet Code On * Off Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.
British Post On * Off Canadian Post On * Off Kix (Netherlands) Post Note: Kix code can misread when scanned sideways or upside down. Use Working Orientation, page 3-22, if your Kix codes will not usually be presented upright to the imager.
Australian Post Interpretation This option controls what interpretation is applied to customer fields in Australian 4-State symbols. Bar Output lists the bar patterns in “0123” format. Numeric N Table causes that field to be interpreted as numeric data using the N Table. Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table. Refer to the Australian Post Specification Tables.
China Post China Post On * Off China Post Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Korea Post Korea Post On * Off Korea Post Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48.
QR Code Note: QR Code can only be read by a 2D imager. < Default All QR Code Settings > QR Code This selection applies to both QR Code and Micro QR Code. * On Off Note: The default applies to firmware with a base number of 31205480. Refer to the Show Software Revision on page 11-2 for information on determining the firmware revision in your unit QR Code Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information.
Data Matrix Note: Data Matrix can only be read by a 2D imager. < Default All Data Matrix Settings > Data Matrix * On Off Data Matrix Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-1500. Minimum Default = 1, Maximum Default = 1500.
MaxiCode Note: MaxiCode can only be read by a 2D imager. < Default All MaxiCode Settings > MaxiCode * On Off MaxiCode Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150.
Aztec Code Note: Aztec Code can only be read by a 2D imager. < Default All Aztec Code Settings > Aztec Code * On Off Aztec Code Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-3750. Minimum Default = 1, Maximum Default = 3750.
8 Imaging Commands The image scanner is like a digital camera in the way it captures, manipulates, and transfers images. The following commands allow you to alter the way the imager performs these functions. Single-Use Basis Imaging Commands with their modifiers send instructions to the imager on a single-use basis, and take effect for a single image capture. Once that capture is complete, the imager reverts to its imaging default settings.
Step 1 - Take a Picture Using IMGSNP Image Snap - IMGSNP An image is taken whenever the hardware button is pressed, or when the Image Snap (IMGSNP) command is processed. The image snap command has many different modifiers that can be used to change the look of the image in memory. Modifiers always begin with numbers and end with a letter (case insensitive). Any number of modifiers may be appended to the IMGSNP command.
L - LED State Determines if the LEDs should be on or off, and when. Ambient illumination (0L) is preferred for taking pictures of color documents, such as ID cards, especially when the imager is in a stand. LED illumination (1L) is preferred when the imager is hand held. LED State is not available when using Decoding Style (0P). 0L LEDs off (default) 1L LEDs on E - Exposure Exposure is used in Manual Style only (2P), and allows you to set the exposure time.
G - Gain Gain is used in Manual Style only (2P). Like a volume control, the gain modifier boosts the signal and multiplies the pixel value. As you increase the gain, the noise in an image is also amplified. 1G No gain (default) 2G Medium gain 4G Heavy gain 8G Maximum gain Example of Gain at 1G: Example of Gain at 4G: Example of Gain at 8G: W - Target White Value Sets the target for the median grayscale value in the captured image.
% - Target Set Point Percentage Sets the target point for the light and dark values in the captured image. A setting of 75% means 75% of the pixels are at or below the target white value, and 25% of the pixels are above the target white value. Altering this setting from the default is not recommended under normal circumstances. To alter grayscale values, W - Target White Value should be used.
Step 2 - Ship a Picture Using IMGSHP Image Ship - IMGSHP An image is taken whenever the button is pressed, or when the Image Snap (IMGSNP) command is processed. The last image is always stored in memory. You can “ship” the image by using the IMGSHP command. The image ship commands have many different modifiers that can be used to change the look of the image output. Modifiers affect the image that is transmitted, but do not affect the image in memory.
C - Compensation Flattens the image to account for variations in illumination across the image. 0C Compensation disabled (default) 1C Compensation enabled Example of Compensation at 0C: Example of Compensation at 1C: D - Pixel Depth Indicates the number of bits per pixel in the transmitted image (KIM or BMP format only).
F - File Format Indicates the desired format for the image. 0F KIM format 1F TIFF binary 2F TIFF binary group 4, compressed 3F TIFF grayscale 4F Uncompressed binary (upper left to lower right, 1 pixel/bit, 0 padded end of line) 5F Uncompressed grayscale (upper left to lower right, bitmap format) 6F JPEG image (default) 8F BMP format (lower right to upper left, uncompressed) H - Histogram Stretch Increases the contrast of the transmitted image. Not available with some image formats.
I - Invert Image Invert image is used to rotate the image around the X or Y axis. 1ix Invert around the X axis (flips picture upside down) 1iy Invert around the Y axis (flips picture left to right) Example of image not inverted: Example of image with Invert Image set to 1ix: Example of image with Invert Image set to 1iy: IF- Noise Reduction Used to reduce the salt and pepper noise in an image.
IR - Image Rotate 0ir Image as snapped (rightside up) (default) 1ir Rotate image 90 degrees to the right 2ir Rotate image 180 degrees (upside down) 3ir Rotate image 90 degrees to the left Example of Image Rotate set to 2ir: Example of Image Rotate set to 0ir: Example of Image Rotate set to 1ir: Example of Image Rotate set to 3ir: J - JPEG Image Quality Sets the desired quality when the JPEG image format is selected. Higher numbers result in higher quality, but larger files.
K - Gamma Correction Gamma measures the brightness of midtone values produced by the image. You can brighten or darken an image using gamma correction. A higher gamma correction yields an overall brighter image. The lower the setting, the darker the image. The optimal setting for text images is 50K.
L, R, T, B, M - Image Cropping Note: Image Cropping should not be used with IMGSHP Modifiers (see page 8-6). Ships a window of the image by specifying the left, right, top, and bottom pixel coordinates. Device columns are numbered 0 through 1279, and device rows are numbered 0 through 959. nL The left edge of the shipped image corresponds to column n of the image in memory. Range: 000 - 640. (Default = 0) nR The right edge of the shipped image corresponds to column n - 1 of the image in memory.
P - Protocol Used for shipping an image. Protocol covers two features of the image data being sent to the host. It addresses the protocol used to send the data (Hmodem, which is an Xmodem 1K variant that has additional header information), and the format of the image data that is sent. 0P None (raw data) 2P None (default for USB) 3P Hmodem compressed (default for RS-232) 4P Hmodem S - Pixel Ship Pixel Ship sizes an image in proportion to its original size.
This filter typically provides better JPEG compression than the standard E Edge Sharpen command (see page 8-15). This filter also works well when shipping pure black and white images (1 bit per pixel). The optimal setting is 26U. 0U Document image filter off (default) 26U Apply document image filter for typical document image nU Apply document image filter using grayscale threshold n. Use lower numbers when the image contrast is lower.
W - Histogram Ship A histogram gives a quick picture of the tonal range of an image, or key type. A low-key image has detail concentrated in the shadows; a high-key image has detail concentrated in the highlights; and an average-key image has detail concentrated in the midtones. This modifier ships the histogram for an image.
Intelligent Signature Capture - IMGBOX IMGBOX allows you to configure the size and location of a signature capture area relative to its proximity to a barcode. This allows you to tailor a signature capture area to a specific form. In order to use IMGBOX, you need a set form where the signature box location is in a known location relative to a barcode. You can input the overall size of the signature area, as well as specify how far the signature area is from the barcode, vertically and horizontally.
The IMGBOX commands have many different modifiers that can be used to change the size and appearance of the signature image output by the imager. Modifiers affect the image that is transmitted, but do not affect the image in memory. Modifiers always begin with a number and end with a letter (case insensitive). Any number of modifiers may be appended to the IMGBOX command. Note: The IMGBOX command will return a NAK unless a window size (width and height) are specified.
F - File Format This option indicates the type of file format in which to save the image. 0F KIM format 1F TIFF binary 2F TIFF binary group 4, compressed 3F TIFF grayscale 4F Uncompressed Binary 5F Uncompressed grayscale 6F JPEG image (default) 7F Outlined image 8F BMP format H - Height of Signature Capture Area The height of the signature capture area must be measured in inches divided by .01. In the example, the height of the area to be captured is 3/8 inch, resulting in a value of H = .
R - Resolution of Signature Capture Area The resolution is the number of pixels that the imager outputs per each minimum bar width. The higher the value for R, the higher the quality of the image, but also the larger the file size. Values begin at 1000. The imager automatically inserts a decimal point between the first and second digit. For example, use 2500 to specify a resolution of 2.5. Set to zero when using the A and B modifiers (see A - Output Image Width and B - Output Image Height on page 8-17).
X - Horizontal Barcode Offset The horizontal barcode offset allows you to offset the horizontal center of the signature capture area. Positive values move the horizontal center to the right and negative values to the left. Measurements are in multiples of the minimum bar width. Example of Horizontal Offset set to 75X: Example of Horizontal Offset set to -75X: Y - Vertical Barcode Offset The vertical barcode offset allows you to offset the vertical center of the signature capture area.
9 OCR Programming Use this section to program the Imager for optical character recognition (OCR). The 2D imager reads 6 to 60 point OCR typeface. Note: OCR is not as secure as barcodes. To enhance security in OCR applications, create an OCR template to match the data, and print an OCR check character. The 2D imager will read OCR-A, OCR-B, U.S. Currency Serial Number (Money), MICR E-13B, and SEMI Font.
OCR-B On allows you to scan characters in the OCR-B font. The default setting allows you to scan any eight digit combination. If you have created an OCR template, character combinations that fit the template can be scanned (see Creating an OCR Template, page 9-3). OCR-B On U.S. Currency Font U.S. Currency On allows you to scan characters in the font used on U.S. currency. The default setting allows you to scan any eight digit combination.
SEMI Font SEMI Font On allows you to scan the SEMI font used in the semiconductor industry. SEMI Font On All OCR Off turns off all OCR capability in the imager, so the imager will be able to scan linear, stacked, matrix, and composite barcodes, but not OCR fonts. However, any OCR templates you have created will be retained in memory. * All OCR Off OCR Templates You can create a custom “template,” or character string that defines the length and content of OCR strings that will be read with your imager.
Template Characters a represents any alphanumeric character (digit or letter) c represents that a check character is verified but not transmitted d represents any digit e represents any available OCR character g represents character from user-defined variable “g” h represents character from user-defined variable “h” i represents character from user-defined variable “g” or “h” k represents that a check character is verified but transmitted l represents any uppercase letter t marks the star
Character Match Sequences On the ASCII Conversion Chart (Code Page 1252), page A-4, find the Hex value that represents the character(s) you want to match. Use the Programming Chart (inside the back cover) to scan the numbers that represent these characters. Example: You need to read three digits, three specific characters (ABC), three digits. The template would be: } ddd414243ddd hex codes for letters A, B, and C To create this template, you would enable the OCR-A font.
Stringing Together Multiple Formats (Creating “Or” Statements) You may want to program the imager to accept many OCR formats. To do this, you would string together each format with a “t.” This tells the imager to read optical characters that match any one of the formats in the template. Example: You need to read any combination of eight digits, or a combination of four digits, two uppercase letters, and two digits.
This template would then let you read data that began with six digits, and had an A, B, or C trailing. So you would be able to read: 654321ABC or 654321BAC or 654321CCC Reading Multi-Row OCR The imager is capable of decoding multi-row OCR text. Note: Reading rows longer than sixteen characters is not recommended. Consider the following example. This example shows serial commands as they would be entered using Quick*View.
OCR Check Character You may want to print and verify a check character in order to enhance the security of your OCR application. The imager can be programmed for almost any type of check character. A number of presets are provided for common check character uses (e.g., modulo 10 and modulo 36). Scan the OCR Modulo 10 or OCR Modulo 36 Check Character barcode to specify the type of check character used in the OCR strings you’re scanning.
OCR Modulo 36 Check Character Scan this symbol to program the OCR template for a simple modulo 36 checksum of the digits 0 through 9 and the letters A through Z. OCR Modulo 36 Check Character OCR User-Defined Check Character You can customize the check character calculation to suit your application. Each character of the check character alphabet can be programmed in its proper order. The number of characters you enter determines the modulo value for the calculation.
2. Enter the characters in order. For each character, look up the corresponding hex value from the ASCII Conversion Chart (Code Page 1252), page A-4. Use the Programming Chart on the inside the back cover of this manual to scan the two symbols for each hex value. 3. Scan the Save barcode on the inside back cover. Example: To program the modulo 11 check character from example #8 on page 9-9, enable the OCR-A font.
Since the result is zero, the message is considered to be valid, so the reader outputs the message: 0123456 2-1-2-1 Weighted Modulo 10 Check Character Starting with the check character and working backward through the message, the imager applies a multiplier of 1, then 2, then 1, then 2, and so on. When the result of the multiplication is greater than 9, add both digits to the running sum. This is often referred to as the LUHN formula.
OCR ISBN Application Example One application of OCR is to read the ISBN characters typically encoded using the OCR-A or OCR-B font. This is especially useful when the ISBN number is not encoded in an EAN-13 barcode. The following example shows how to configure the imager to read the ISBN strings on books in Japan. After you have followed the steps below, you will be able to scan the following ISBN number or the additional data below it, depending on the line of text at which the imager is aimed. 1.
5. Finally, set up the ISBN check digit, which is a special position-weighted modulo 11 checksum. The imager automatically invokes the ISBN checksum for template rows that are: 1.) at least fourteen characters long, 2.) whose first four characters are the letters “ISBN,” 3.) whose last character is a check character, and 4.) when the modulo 11 check character “0123456789X” is programmed.
Exit Selections Save OCR Template Discard OCR Template 9 - 14 4600rp, 4600g/4600r, 4800i User’s Guide
10 Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the imager. Refer to page 2-8 enable Control + ASCII mode.
The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country Codes United States [ \ ] 6 - Belgium [ < ] 6 - Scandinavia 8 < 9 6 - France ^ 8 $ 6 = Germany à + 6 - Italy \ + 6 - Switzerland < ..
Supported Interface Keys ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US HEX 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F IBM AT/XT and PS/2 Compatibles, WYSE PC/AT Supported Keys Reserved Enter (KP) Cap Lock ALT make ALT break CTRL make CTRL break CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Supported Interface Keys ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US HEX 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F IBM, Memorex Telex (102)* Supported Keys Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab F19 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Memorex Telex (88)** Supported Keys Res
Supported Interface Keys ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US HEX 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Esprit 200, 400 ANSI Supported Keys Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Esprit 200, 400 ASCII Supported Keys Reserved New Line N/A N/A N/A N/
Supported Interface Keys ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US DEL 10 - 6 HEX 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7F Apple Mac/iMac Supported Keys Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make TAB APPLE break TAB Del RETURN Ins Help ESC F11 Home Prnt Scrn BACKSPACE LSHIFT TAB F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 BACKSPA
11 Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, included in the Appendix A, page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled. Add Code I.D.
Show Scan Driver Revision Scan the barcode below to output the scan driver revision. The scan driver controls image capture. You may use the Show Scan Driver Revision option if you have firmware with a base number of 31205480. Refer to the Show Software Revision below for information on determining the firmware revision in your unit. Show Scan Driver Revision Show Software Revision Scan the barcode below to output the current software revision, unit serial number, and other product information.
Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the imager displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming code is output to the terminal. Note: This feature should not be used during normal imager operation.
Note: The PQA report is sent out as a second data/beep sequence after the barcode data. The report has its own Hand Held Products code ID of >(0X3E) so it can be uniquely identified. You can exit Full Report mode by either typing the menu command, 2D_PQA0, if you are using Quick*View, or by scanning the following barcode: Exit Note: For additional information on interpreting your read results, please refer to Hand Held Products Quick Check 2D Print Assessment User’s Guide.
Configure Configure displays the programming and configuration data of the imager. The imager's programming and configuration data is grouped into different categories. Each category is displayed as a tree item under the "Configure" tree node in the application explorer. When one of these tree nodes is clicked, the right-hand side is loaded with the parameters' form belonging to that particular category.
Quick*View Quick*View is a Microsoft Windows® program that displays decoded symbol messages and captures images (for instance, ID photographs) from the imager. Barcode information and images are displayed in the Quick*View window. Installing Quick*View from the Web 1. Access the Hand Held Products web site at www.handheld.com. 2. Click on Search and enter Quick*View. 3. Click on Search. 4. Click on the entry for Software. Select Quick*View Software Utility. 5.
12 Serial Programming Commands The serial programming commands can be used in place of the programming barcodes. Both the serial commands and the programming barcodes will program your imager. For complete descriptions and examples of each serial programming command, refer to the corresponding programming barcode in this manual. The device must be set to an RS-232 interface (see page 1-11). The following commands can be sent via a PC COM port using terminal emulation software.
Query Commands Several special characters can be used to query the device about its settings. ^ ? * What is the default value for the setting(s). What is the device’s current value for the setting(s). What is the range of possible values for the setting(s). (The device’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.
When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command. Examples of Query Commands In the following examples, a bracketed notation [ ] depicts a non-displayable response. Example #1:What is the range of possible values for Codabar Coding Enable? Enter: cbrena*.
Trigger Commands You can activate and deactivate the imager with serial trigger commands. First, the imager must be put in Manual/Serial Trigger Mode either by scanning the Manual/Serial Trigger Mode barcode (page 3-4), or by sending the Manual/ Serial Menu Command (page 12-9).
Menu Commands Note: Not all menu commands apply to all imager models.
Selection Program Keyboard Country Keyboard Style 12 - 6 Serial Command Setting Page * Indicates default # Indicates a numeric entry *U.S.A.
Selection Keyboard Modifiers Baud Rate Word Length: Data Bits, Stop Bits, and Parity RS-232 Receiver Timeout Setting Serial Command Page * Indicates default # Indicates a numeric entry *Control + ASCII Off KBDCAS0 2-8 DOS Mode Control + ASCII KBDCAS1 2-8 Windows Mode Control + ASCII KBDCAS2 2-8 *Turbo Mode Off KBDTMD0 2-8 Turbo Mode On KBDTMD1 2-8 *Numeric Keypad Off KBDNPS0 2-8 Numeric Keypad On KBDNPS1 2-8 *Auto Direct Conn. Off KBDADC0 2-9 Auto Direct Conn.
Selection RS-232 Handshaking Wand Emulation Connection Data Block Size Delay Between Blocks Overall Checksum Wand Emulation Transmission Rate Wand Emulation Polarity Wand Emulation Idle Serial Command Setting Page * Indicates default # Indicates a numeric entry *RTS/CTS Off 232CTS0 2-12 RTS/CTS On 232CTS1 2-12 *XON/XOFF Off 232XON0 2-12 XON/XOFF On 232XON1 2-12 *ACK/NAK Off 232ACK0 2-12 ACK/NAK On 232ACK1 2-12 Same Code Format TERMID64 2-13 Code 39 Format TERMID61 2-13
Selection Beeper Volume - Good Read Beeper Pitch - Good Read (Frequency) Beeper Duration - Good Read LED - Good Read Number of Beeps - Good Read Good Read Delay User-Specified Good Read Delay Manual/Serial Trigger Manual Trigger, Low Power In-Stand Sensor Mode Scan Stand Presentation Presentation LED Timer Presentation Sensitivity Setting Serial Command Page * Indicates default # Indicates a numeric entry Off BEPLVL0 3-1 Low BEPLVL1 3-1 *Medium (default for 4600g/ 4600r/4600rp) BEPLVL2
Selection Serial Command Setting Page * Indicates default # Indicates a numeric entry Streaming Presentation Streaming Presentation Mode TRGMOD8 3-7 Hands Free Time-Out Range 0 - 300,000 ms TRGPTO###### 3-8 Short (500 ms) DLYRRD500 3-8 *Medium (750 ms) DLYRR750 3-8 Long (1000 ms) DLYRRD1000 3-8 Extra Long (2000 ms) DLYRRD2000 3-8 Range 0 - 30,000 ms DLYRRD##### 3-9 Off PWRLDC0 3-9 Low (50%) PWRLDC50 3-9 *High (100%) PWRLDC100 3-9 *Lights On SCNLED1 3-10 Lights Off S
Selection Decode Search Mode Preferred Symbology Output Sequence Editor Require Output Sequence Multiple Symbols No Read Print Weight Video Reverse Working Orientation Setting * Indicates default Serial Command # Indicates a numeric entry Page Full Omnidirectional (Default for 2D imagers) DECMOD0 3-14 Quick Omnidirectional DECMOD1 3-14 Advanced Linear Decoding (Default for PDF imagers) DECMOD2 3-14 On PRFENA1 3-15 *Off PRFENA0 3-15 High Priority Symbology PRFCOD## 3-15 Low Pri
Selection Suffix Function Code Transmit Intercharacter Delay User Specified Intercharacter Delay Serial Command Setting * Indicates default # Indicates a numeric entry Page Add Suffix SUFBK2## 4-4 Clear One Suffix SUFCL2 4-4 Clear All Suffixes SUFCA2 4-4 *Enable RMVFNC0 4-4 Disable RMVFNC1 4-4 Range 0 - 495 ms DLYCHR## 4-5 Delay Length (0 - 495 ms) DLYCRX## 4-6 Character to Trigger Delay DLY_XX### 4-6 Interfunction Delay Range 0 - 495 ms DLYFNC## 4-6 Intermessage Delay Ra
Selection Wand Emulation Multi Block Delay Between Blocks Overall Checksum Wand Emulation Transmission Rate Wand Emulation Polarity Wand Emulation Idle Data Block Size Secondary Trigger Model Hands Free Time-Out Scan Stand Presentation Setting * Indicates default Serial Command # Indicates a numeric entry Page 5 ms WNDDLY0 6-3 *50 ms WNDDLY1 6-3 150 ms WNDDLY2 6-3 500 ms WNDDLY3 6-3 On WNDCHK1 6-4 *Off WNDCHK0 6-4 10 WNDSPD0 6-4 *25 WNDSPD1 6-4 40 WNDSPD2 6-4 80 WNDSP
Selection Codabar Codabar Serial Command Setting * Indicates default # Indicates a numeric entry Page Default All Codabar Settings CBRDFT 7-3 Off CBRENA0 7-3 *On CBRENA1 7-3 *Don’t Transmit CBRSSX0 7-3 Transmit CBRSSX1 7-3 *No Check Char.
Selection Interleaved 2 of 5 Interleaved 2 of 5 Interleaved 2 of 5 Check Digit Interleaved 2 of 5 Message Length Code 93 Code 93 Code 93 Message Length Straight 2 of 5 Industrial Straight 2 of 5 Industrial Straight 2 of 5 Industrial Message Length Straight 2 of 5 IATA Straight 2 of 5 IATA Straight 2 of 5 IATA Message Length Matrix 2 of 5 Matrix 2 of 5 Setting * Indicates default Serial Command # Indicates a numeric entry Page Default All Interleaved 2 of 5 Settings I25DFT 7-10 Off I25ENA0 7-1
Selection Matrix 2 of 5 Message Length Code 11 Code 11 Code 11 Check Digits Required Code 11 Message Length Code 128 Code 128 ISBT Concatenation Serial Command Setting Page * Indicates default # Indicates a numeric entry Minimum (1 - 80) *4 X25MIN## 7-15 Maximum (1 - 80) *80 X25MAX## 7-15 Default All Code 11 Settings C11DFT 7-15 *Off C11ENA0 7-16 On C11ENA1 7-16 1 Check Digit C11CK20 7-16 *2 Check Digits C11CK21 7-16 Minimum (1 - 80) *4 C11MIN## 7-16 Maximum (1 - 80) *80 C11
Selection UPC-A Number System UPC-A 2 Digit Addenda Setting * Indicates default Serial Command # Indicates a numeric entry Page Off UPANSX0 7-20 *On UPANSX1 7-20 *Off UPAAD20 7-21 On UPAAD21 7-21 *Off UPAAD50 7-21 On UPAAD51 7-21 UPC-A Addenda Required *Not Required UPAARQ0 7-21 Required UPAARQ1 7-21 UPC-A Addenda Separator Off UPAADS0 7-21 *On UPAADS1 7-21 UPC-A/EAN-13 with Extended Coupon Code *On CPNENA1 7-22 Off CPNENA0 7-22 Default All UPC-E Settings UPEDFT
Selection EAN/JAN-13 EAN/JAN-13 Check Digit EAN/JAN-13 2 Digit Addenda Serial Command Setting * Indicates default # Indicates a numeric entry Page Off E13ENA0 7-25 *On E13ENA1 7-25 Off E13CKX0 7-25 *On E13CKX1 7-25 2 Digit Addenda On E13AD21 7-26 *2 Digit Addenda Off E13AD20 7-26 5 Digit Addenda On E13AD51 7-26 *5 Digit Addenda Off E13AD50 7-26 EAN/JAN-13 Addenda Required *Not Required E13ARQ0 7-26 Required E13ARQ1 7-26 EAN/JAN-13 Addenda Separator Off E13ADS0 7-26
Selection MSI Check Character MSI Message Length Plessey Code Plessey Code Plessey Message Length GS1 DataBar Omnidirectional GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Limited GS1 DataBar Expanded GS1 DataBar Expanded GS1 DataBar Expanded Msg. Length PosiCode PosiCode PosiCode Msg.
Selection Trioptic Code Codablock F Codablock F Codablock F Msg. Length Code 16K Code 16K Code 16K Msg. Length Code 49 Code 49 Code 49 Msg.
Selection EAN•UCC Composite Codes Msg.
Selection China Post China Post Msg. Length Korea Post Korea Post Korea Post Msg. Length QR Code QR Code QR Code Msg. Length Data Matrix Data Matrix Data Matrix Msg.
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Imaging Default Commands Image Snap Default all Imaging Commands IMGDFT 8-1 Imaging Style - Decoding SNPSTY0 8-2 *Imaging Style - Photo SNPSTY1 8-2 Imaging Style - Manual SNPSTY2 8-2 Beeper On SNPBEP1 8-2 *Beeper Off SNPBEP0 8-2 Exposure (1-7874 microseconds) SNPEXP 8-3 *Gain - None SNPGAN1 8-4 Gain - Medium SNPGAN2 8-4 Gain - Heavy SNPGAN4 8-4 Gain - Maximum SNPGAN8 8-4 Delta for Acce
Selection Image Ship 12 - 24 Serial Command Setting Page * Indicates default # Indicates a numeric entry *Infinity Filter - Off IMGINF0 8-6 Infinity Filter - On IMGINF1 8-6 *Compensation Off IMGCOR0 8-7 Compensation On IMGCOR1 8-7 *Pixel Depth - 8 bits/pixel (grayscale) IMGBPP8 8-7 Pixel Depth - 1 bit/pixel (B&W) IMGBPP1 8-7 *Don’t Sharpen Edges IMGEDG0 8-7 Sharpen Edges (0-23) IMGEDG## 8-7 *File Format - JPEG IMGFMT6 8-8 File Format - KIM IMGFMT0 8-8 File Format - TIFF
Selection Image Ship (continued) Setting * Indicates default Serial Command # Indicates a numeric entry Page Image Crop - Bottom (0-480) *479 IMGWNB### 8-12 Image Crop - Margin (0-238) *0 IMGMAR### 8-12 Protocol - None (raw) IMGXFR0 8-13 Protocol - None (default USB) IMGXFR2 8-13 Protocol - Hmodem Compressed IMGXFR3 8-13 Protocol - Hmodem IMGXFR4 8-13 Ship Every Pixel IMGSUB1 8-13 Ship Every 2nd Pixel IMGSUB2 8-13 Ship Every 3rd Pixel IMGSUB3 8-13 *Document Image Filter Off
Selection Serial Command Setting * Indicates default 12 - 26 Page OCR Mod. 10 Check Char. “OCRCHK01234 56789” 9-8 OCR Mod. 36 Check Char. “OCRCHK01234 56789ABCDEFG HIJKLMNOPQRSTUVWXYZ” 9-9 OCR User-Defined Check Char. OCRCHK 9-9 3-1-3-1 Weighted Mod. 10 Check Char. OCRCHK3-1-3-1 9-10 2-1-2-1 Weighted Mod. 10 Check Char.
13 Product Specifications 4600g and 4600r Parameter Specification 4600g/4600r Dimensions (Typical): Height 6.2 inches (15.7 cm) Length 5.3 inches (13.5 cm) Width 3.2 inches (8.1 cm) Weight 6.5 ounces (184.3 g) 4600rp Dimensions (Typical): Height (Stand and imager) 8.2 inches (20.8 cm) Length (Stand) 5.4 inches (13.7 cm) Length (Back edge of stand to front of imager nose with image in upright position) 6.5 inches (16.5 cm) Width (Stand base) 3.5 inches (8.
Mechanical Drop Operational after 50 drops from 6 feet (1.8 m) to concrete Vibration Withstands 5G peak from 22 to 300 Hz ESD Tolerance 15 kV to any external surface Agency Compliance International: CB Scheme to IEC60950-1 and IEC60825-1 (Class 1 LED) (4600r only) South Korea: MIC Australia/NZ: C-Tick marked.
Scanning 334mA 170mA Standby Inrush Low Power 80mA 500mA 100µA 55mA Current Draw (Typical): Input 5V 12V Power Supply Noise Rejection Maximum 100mV peak to peak, 10 to 100 kHz Temperature Ranges: Operating +14°F to +122°F (-10°C to +50°C) Storage -40°F to +158°F (-40°C to +70°C) Humidity 0 to 95% non-condensing Mechanical Drop Operational after 50 drops from 6.
13 - 4 2 3 4 5 6 7 8 9 10 1 Cord shield Prog 1 Supply ground Terminal clock Terminal data Power connection (Refer to table on page 13-1) Keyboard data Keyboard clock connects to the imager handle 10 Pin RJ41 Modular Plug Standard Cable Pinouts Keyboard Wedge 4600rp, 4600g/4600r, 4800i User’s Guide
4600rp, 4600g/4600r, 4800i User’s Guide connects to your terminal 9 Pin Type D Female connects to the imager handle 10 Pin Modular Plug 5 Volt power 9 connection Cord shield 8 Supply ground 7 6 5 4 3 2 1 Barcode data output 2 Cord shield 3 Tied to 5 Volt power 4 Supply ground 5 6 Barcode data output 7 5 Volt power connection 8 9 10 1 Wand Emulation 13 - 5
13 - 6 2 Cord shield 3 Tied to 5 Volt power 4 Supply ground 5 Receive data - Serial data to imager 6 Transmit data - Serial data from imager 7 5 Volt power connection 8 Request to send data 9 Clear to send data 10 1 connects to the imager handle 10 Pin RJ41 Modular Plug Serial Output 4600rp, 4600g/4600r, 4800i User’s Guide
connects to the imager handle 10 Pin Modular Plug 2 Data + 3 Tied to 5 volt power 4 Supply ground 5 6 7 5 volt power connection 8 9 10 Data - 1 USB 4600rp, 4600g/4600r, 4800i User’s Guide 13 - 7
13 - 8 4600rp, 4600g/4600r, 4800i User’s Guide
14 Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. See "Customer Support" on page 15-1 for further information. Maintenance Your imager provides reliable and efficient operation with a minimum of care.
Replacing the Interface Cable The standard interface cable is attached to the imager with an 10-pin modular connector. When properly seated, the connector is held in the imager’s handle by a flexible retention tab. The interface cable is designed to be field replaceable. • Order replacement cables from Hand Held Products or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable. To Replace the 4600g/4600r Interface Cable: 1.
To Replace the 4600rp Interface Cable: 1. Turn the power to the host system OFF. 2. Disconnect the imager’s cable from the terminal or computer. 3. Rotate the imager downward to the last position. 4. Locate the small hole on the side of the stand. This is the cable release. 5. Straighten one end of a paper clip. Cable Release 6. Insert the end of the paper clip into the small hole and press in. This depresses the retention tab, releasing the connector.
8. Screw the cord lock back in place over the cord. Troubleshooting The imager automatically performs self-tests whenever you turn it on. If your imager is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem. Is the power on? Is the red aiming illumination line on? If the red aiming illumination line isn’t illuminated, check that: • The cable is connected properly. • The host system power is on (if external power isn’t used). • The trigger works.
1. Scan the sample barcodes in the back of this manual. If the imager reads the sample barcodes, check that your barcode is readable. Verify that your barcode symbology is enabled (see Chapter 7). 2. If the imager still can’t read the sample barcodes, scan "All Symbologies" on page 7-2. If you aren’t sure what programming options have been set in the imager, or if you want the factory default settings restored, scan Standard Product Default Settings on page 12-4.
14 - 6 4600rp, 4600g/4600r, 4800i User’s Guide
15 Customer Support Technical Assistance If you need assistance installing or troubleshooting, please call your Distributor or the nearest Hand Held Products technical support office: North America/Canada Telephone: (800) 782-4263 Fax number: (315) 554-6705 E-mail: natechsupport@handheld.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: latechsupport@handheld.com Brazil Telephone: +55 (21) 3535-9100 Fax: +55 (21) 3535-9105 E-mail: brsuporte@handheld.
Online Technical Assistance You can also access technical assistance online at www.handheld.com. For Further Information To download the full User’s Guide for these products, visit our website at www.handheld.com. Product Service and Repair Hand Held Products provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, return the unit to Hand Held Products (postage paid) with a copy of the dated purchase record attached.
Japan Telephone: +813-5770-6312 Fax: +813-5770-6313 E-mail: apservice@handheld.com Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.handheld.com. Limited Warranty Hand Held Products, Inc. ("Hand Held Products") warrants its products to be free from defects in materials and workmanship and to conform to Hand Held Products’ published specifications applicable to the products purchased at the time of shipment.
ANY PRODUCT SOLD HEREUNDER (WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL AMOUNT PAID TO HAND HELD PRODUCTS FOR THE PRODUCT. THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HAND HELD PRODUCTS MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES.
A Appendix A Symbology Chart Symbology AIM ID Possible AIM ID Modifiers (m) All Symbologies Code ID (hex) (0x99) 4-CB (4-State Customer Barcode) ]X0 Australian Post ]X0 Aztec Code ]zm British Post ]X0 B (0x42) Canadian Post ]X0 C (0x43) China Post ]X0 Codabar ]Fm 0-1 Codablock F ]Om 0, 1, 4, 5, 6 Code 11 ]H3 Code 128 ]Cm 0, 1, 2, 4 j (0x6A) Code 16K ]Km 0, 1, 2, 4 o (0x6F) Code 32 Pharmaceutical (PARAF) ]X0 Code 39 ]Am 0, 1, 3, 4, 5, 7 b (0x62) Code 49 ]Tm 0, 1,
Symbology AIM ID Possible AIM ID Modifiers (m) Code ID (hex) MicroPDF417 ]Lm 3-5 R (0x52) MSI ]Mm 0 g (0x67) No Read (0x9C) OCR-A ]o1 O (0x4F) OCR-B ]o2 O (0x4F) MICR E-13B ]ZE O (0x4F) U.S.
Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Note: Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Refer to Data Editing beginning on page 4-1 and Data Formatting beginning on page 5-1 for information about using Code ID and AIM ID.
ASCII Conversion Chart (Code Page 1252) Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings.
Dec Hex Char Dec Hex Char Dec Hex 160 A0 192 C0 À 224 E0 à 161 A1 ¡ 193 C1 Á 225 E1 á 162 A2 ¢ 194 C2 Â 226 E2 â ƒ 163 A3 £ 195 C3 Ã 227 E3 ã 84 „ 164 A4 ¤ 196 C4 Ä 228 E4 ä 85 … 165 A5 ¥ 197 C5 Å 229 E5 å 134 86 † 166 A6 ¦ 198 C6 Æ 230 E6 æ 135 87 ‡ 167 A7 § 199 C7 Ç 231 E7 ç 136 88 ˆ 168 A8 ¨ 200 C8 È 232 E8 è 137 89 ‰ 169 A9 © 201 C9 É 233 E9 é 138 8A Š 170 AA ª 202 CA Ê 234 EA ê 1
Code Page Mapping of Printed Barcodes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, select the code page with which the barcodes were created. The data characters should then appear properly. Note: The Code Page option is available for Code 39, Code 93, and Code 128.
4600rp, 4600g/4600r, 4800i User’s Guide A-7
A-8 4600rp, 4600g/4600r, 4800i User’s Guide
Sample Symbols UPC-A 0 123456 7890 Code 128 Code 128 Code 39 BC321 Code 93 123456-9$ Interleaved 2 of 5 1234567890 EAN-13 9 780330 290951 Codabar A13579B Straight 2 of 5 Industrial 123456 4600rp, 4600g/4600r, 4800i User’s Guide
Sample Symbols Matrix 2 of 5 RSS-14 6543210 PDF417 (01)00123456789012 Postnet Car Registration Zip Code Code 49 1234567890 Data Matrix QR Code Test Symbol Numbers 4-CB (4-State Customer Barcode) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T 4600rp, 4600g/4600r, 4800i User’s Guide
Sample Symbols Aztec Micro PDF417 Package Label MaxiCode Test Message OCR-A with Modulo 36 check character 4600rp, 4600g/4600r, 4800i User’s Guide Test Message OCR-B with Modulo 10 check character
OCR Programming Chart a c d e g h l r t 4600rp, 4600g/4600r, 4800i User’s Guide
OCR Programming Chart T O A D Discard Save 4600rp, 4600g/4600r, 4800i User’s Guide
Programming Chart A B C D E F 0 1 2 3 4600rp, 4600g/4600r, 4800i User’s Guide
Programming Chart 4 5 6 7 8 9 Save Discard Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
Hand Held Products, Inc. 700 Visions Drive P.O.