Installation Guide

70
10' x 14' ROOF PANELS
PARTS REQUIRED:
7/16 x 48 x 96"
(1,1 x 121,9 x 243,8 cm)
x1
x4
2" (5,1 cm)
3/4" GAUGE
BLOCK
Roof panels may cause serious injury until securely fastened.
Note: Install all roof panels with the rough side up (painted grid lines).
Move to the opposite end.
Using the long edge of the panel as a lever,
move the panel side-to-side until the top corner
is ush to the peak (Fig. B) and there is a 3/4"
measurement on the rafter (Fig. C).
Secure panel with (2) 2" nails in the corners.
2
Place the 48" x 96" panel on rafters with a
3/4" measurement on the rafter (Fig A)
and the panel ush at the peak (Fig. B).
Secure panel with (2) 2" nails in the corners.
Two
Nails
48"
x 96"
Flush at
peak
Fig. B
BEGIN
1
3/4"
(1,9 cm)
Gauge Block
3/4"
(1,9 cm)
Gauge Block
Fig. A
Fig. C
Flush at
peak
Fig. B
Two
Nails