User's Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- Regulatory Information
- Safety Instruction
- Available Model
- Chapter 1 Overview
- Chapter 2 Appearance
- Chapter 3 Installation
- Chapter 4 Wiring
- Chapter 5 Activation
- Chapter 6 Local Settings
- Chapter 7 Client Software Configuration
- 7.1 Configuration Flow of Client Software
- 7.2 Device Management
- 7.3 Group Management
- 7.4 Person Management
- 7.4.1 Add Organization
- 7.4.2 Configure Basic Information
- 7.4.3 Issue a Card to One Person
- 7.4.4 Collect Fingerprint via Client
- 7.4.5 Collect Fingerprint via Access Control Device
- 7.4.6 Configure Access Control Information
- 7.4.7 Customize Person Information
- 7.4.8 Configure Resident Information
- 7.4.9 Configure Additional Information
- 7.4.10 Import and Export Person Identify Information
- 7.4.11 Import Person Information
- 7.4.12 Export Person Information
- 7.4.13 Get Person Information from Access Control Device
- 7.4.14 Move Persons to Another Organization
- 7.4.15 Issue Cards to Persons in Batch
- 7.4.16 Report Card Loss
- 7.4.17 Set Card Issuing Parameters
- 7.5 Configure Schedule and Template
- 7.6 Set Access Group to Assign Access Authorization to Persons
- 7.7 Configure Advanced Functions
- 7.7.1 Configure Device Parameters
- 7.7.2 Configure Remaining Open/Closed
- 7.7.3 Configure Multi-Factor Authentication
- 7.7.4 Configure Custom Wiegand Rule
- 7.7.5 Configure Card Reader Authentication Mode and Schedule
- 7.7.6 Configure First Person In
- 7.7.7 Configure Anti-Passback
- 7.7.8 Configure Device Parameters
- 7.8 Configure Linkage Actions for Access Control
- 7.9 Door Control
- 7.10 Event Center
- 7.11 Time and Attendance
- 7.12 Remote Configuration (Web)
- 7.12.1 View Device Information
- 7.12.2 Change Device Password
- 7.12.3 Time Management
- 7.12.4 System Maintenance
- 7.12.5 Configure RS-485 Parameters
- 7.12.6 Security Mode Settings
- 7.12.7 Network Parameters Settings
- 7.12.8 Report Strategy Settings
- 7.12.9 Network Center Parameters Settings
- 7.12.10 Configure Wi-Fi
- 7.12.11 Set Relay Parameters
- 7.12.12 Set Access Control Parameters
- 7.12.13 Set CPU Card Reading Mode
- 7.12.14 Configure Volume Input or Output
- 7.12.15 Operate Relay
- 7.13 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. Dimension
- Appendix C. Communication Matrix and Device Command
6.3.4 Set Wiegand Parameters
You are able to set the Wiegand direcon (send/receive) and the Wiegand mode (Wiegand 26/
Wiegand 34).
Steps
1. Move the cursor and select Comm. → Wiegand .
Figure 6-5 Wiegand Sengs
2. Se
t the Wiegand parameters.
Direcon
Send
The de
vice can connect to the access controller to upload the card No. bia the Wiegand 26
or the Wiegand 34 mode.
Receive
The terminal can connect to the Wiegand card readers. No need to congure the Wiegand
mode.
Mode
Wieg
and 26 and Wiegand 34 can be selected. The default Wiegand mode is Wiegand 34.
3. Press * and select Yes to save the
sengs and exit the page.
6.3.5 Set RS-485 Parameters
The face recognion terminal can connect card reader via the RS-485 terminal.
St
eps
1. Move the cursor and select Comm. → RS-485 on the Home page to enter the RS-485 page.
Access Control Terminal User Manual