Product Chart
Table Of Contents
- Legal Information
- Symbol Conventions
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Appearance
- Chapter 3 Installation
- Chapter 4 Wiring
- Chapter 5 Activation
- Chapter 6 Quick Operation
- Chapter 7 Basic Operation
- Chapter 8 Configure the Device via the Mobile Browser
- 8.1 Login
- 8.2 Search Event
- 8.3 User Management
- 8.4 Configuration
- 8.5 Door Operation
- Chapter 9 Quick Operation via Web Browser
- Chapter 10 Operation via Web Browser
- 10.1 Login
- 10.2 Forget Password
- 10.3 Live View
- 10.4 Person Management
- 10.5 Search Event
- 10.6 Configuration
- 10.6.1 Set Local Parameters
- 10.6.2 View Device Information
- 10.6.3 Set Time
- 10.6.4 Set DST
- 10.6.5 Change Administrator's Password
- 10.6.6 View Device Arming/Disarming Information
- 10.6.7 Network Settings
- 10.6.8 Set Video and Audio Parameters
- 10.6.9 Set Image Parameters
- 10.6.10 Access Control Settings
- 10.6.11 Card Settings
- 10.6.12 Set Privacy Parameters
- 10.6.13 Time and Attendance Settings
- 10.6.14 Set Biometric Parameters
- 10.6.15 Set Preference
- 10.6.16 Upgrade and Maintenance
- 10.6.17 Device Debugging
- 10.6.18 Log Query
- 10.6.19 Security Mode Settings
- 10.6.20 Certificate Management
- Chapter 11 Client Software Configuration
- 11.1 Configuration Flow of Client Software
- 11.2 Device Management
- 11.3 Group Management
- 11.4 Person Management
- 11.5 Configure Schedule and Template
- 11.6 Set Access Group to Assign Access Authorization to Persons
- 11.7 Configure Advanced Functions
- 11.8 Door Control
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. Tips When Collecting/Comparing Face Picture
- Appendix C. Tips for Installation Environment
- Appendix D. Dimension
- Appendix E. Communication Matrix and Device Command
7.4.1 Delete Data
Delete user data.
On the Home page, select Data → Delete Data → User Data . All user data added in the device will
be deleted.
7.4.2 Import Data
Steps
1.
Plug a USB ash drive in the device.
2.
On the Home page, tap Data → Import Data .
3.
Tap User Data, Face Data or Access Control Parameters .
Note
The imported access control parameters are conguraon les of the device.
4.
Enter the created password when you exported the data. If you do not create a password when
you exported the data, leave a blank in the input box and tap OK immediately.
Note
●
If you want to transfer all user informaon from one device (Device A) to another (Device B),
you should export the informaon from Device A to the USB ash drive and then import from
the USB ash drive to Device B. In this case, you should import the user data before imporng
the prole photo.
●
The supported USB
ash drive format is FAT32.
●
The imported pictures should be saved in the folder (named enroll_pic) of the root directory
and the picture's name should be follow the rule below:
Card No._Name_Department_Employee ID_Gender.jpg
●
If the folder enroll_pic cannot save all imported pictures, you can create another folders,
named enroll_pic1, enroll_pic2, enroll_pic3, enroll_pic4, under the root directory.
●
The employee ID should be less than 32 characters. It can be a combinaon of lower leers,
upper leers, and numbers. It should not be duplicated, and should not start with 0.
●
Requirements of face picture should follow the rules below: It should be taken in full-face
view, directly facing the camera. Do not wear a hat or head covering when taking the face
picture. The format should be JPEG or JPG.
7.4.3 Export Data
Steps
1.
Plug a USB
ash drive in the device.
2.
On the Home page, tap Data → Export Data .
3.
Tap Face Data, Event Data, User Data, or Access Control Parameters.
DS-K1T321 Series Face Recognion Terminal
39