User's Manual

Table Of Contents
Note
The
conguraon le contains the device parameters.
Export
Conguraon File
Export the conguraon le from the device to the local PC.
Note
The
conguraon le contains the device parameters.
Upgrade
On the Device for Management page, click R
emote Conguraon → System → System
Maintenance to enter the System Maintenance tab.
Select a device type from the drop-down list, click Browse and select an upgrade le from the local
computer, and click Upgrade.
Note
If you select Card reader as the device type, you should also select a card reader No. from the
dr
op-down list.
The upgrade will lasts for about 2 min. Do not power o during the upgrading. Aer upgrading,
the de
vice will reboot automacally.
7.12.6
Congure RS-485 Parameters
You can set the RS-485 parameters including the baud rate, data bit, stop bit, parity type,
communicaon mode, work mode, and connecon mode.
Steps
1. Click Maintenance and Management → Device to enter the device list.
2. Click
to enter the remote conguraon page.
3. Click S
ystem → RS-485 Sengs to enter the Conguring the RS-485 Parameters tab.
4. Select the serial No. of the port from the drop-down list to set the RS-485 parameters.
5. Set the baud rate, data bit, the stop bit, parity, ow control, communicaon mode, working
mode, and the connecon mode from the drop-down list.
6. Click Sa
ve and the congured parameters will be applied to the device automacally.
Note
Aer changing the working mode, the device will be rebooted. A prompt will be popped up
aer changing the working mode.
Face Recognion Terminal User Manual