DS-K3B501S Series Swing Barrier Quick Start Guide
DS-K3B501S Series Swing Barrier Quick Start Guide Legal Information ©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons.
DS-K3B501S Series Swing Barrier Quick Start Guide PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS. Data Protection During the use of device, personal data will be collected, stored and processed.
DS-K3B501S Series Swing Barrier Quick Start Guide Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
DS-K3B501S Series Swing Barrier Quick Start Guide under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.
DS-K3B501S Series Swing Barrier Quick Start Guide Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage. Dangers: Follow these safeguards to prevent serious injury or death.
DS-K3B501S Series Swing Barrier Quick Start Guide Cautions: • Stainless steel may be corroded in some circumstances. You need to clean and care the device by using the stainless steel cleaner. It is suggested to clean the device every month. • Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
DS-K3B501S Series Swing Barrier Quick Start Guide Available Models Product Name Swing Barrier Model Description DS-K3B501S-L Left Pedestal DS-K3B501S-M Middle Pedestal DS-K3B501S-R Right Pedestal Scan the QR code to get User Manual of Swing Barrier. Note that mobile data charges may apply if Wi-Fi is unavailable.
DS-K3B501S Series Swing Barrier Quick Start Guide Contents Chapter 1 Overview .................................................................................................................... 1 1.1 Introduction ........................................................................................................................... 1 1.2 Main Features ........................................................................................................................ 1 Chapter 2 Wiring .............
DS-K3B501S Series Swing Barrier Quick Start Guide 4.3 Initialize Device .................................................................................................................... 24 4.4 Switch to RS-485/RS-232 Mode ........................................................................................... 25 4.5 Switch Relay Output Mode (NO/NC) .................................................................................... 26 4.5.1 Barrier Control Relay Output Mode ...........................
DS-K3B501S Series Swing Barrier Quick Start Guide Chapter 1 Overview 1.1 Introduction The swing barrier with two barriers and 12 IR lights is designed to detect unauthorized entrance or exit. By adopting the swing barrier integratedly with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc. It is widely used in attractions, stadiums, construction sites, residences, etc. 1.
DS-K3B501S Series Swing Barrier Quick Start Guide • Barrier remains open when powered down • Fire alarm passing When the fire alarm is triggered, the barrier will be open automatically for emergency evacuation • Valid passing duration settings System will cancel the passing permission if a person does not pass through the lane within the valid passing duration • Opens/Closes barrier according to the schedule template • Up to 3000 visitor cards and up to 60,000 cards except for visitor cards can be added 2
DS-K3B501S Series Swing Barrier Quick Start Guide Chapter 2 Wiring 2.1 Components Introduction By default, basic components of the turnstile are connected well. The pedestals can communicate by wiring the interconnecting cables. And the turnstile supports wiring the AC electric supply for the whole system's power supply. Note The voltage fluctuation of the electric supply is between 100 VAC and 220 VAC, 50 to 60 Hz. The picture displayed below describes each component's position on the turnstile.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure 2-2 Components 2 Note If the turnstile contains two lanes, standing at the entrance position, the IR boards on the left pedestal are the IR sending boards. The IR boards on the right pedestal are the IR receiving boards. The IR boards on the left side of the middle pedestal are the IR receiving boards, while the IR boards on the right side of the middle pedestal are the IR sending boards. 2.
DS-K3B501S Series Swing Barrier Quick Start Guide Note • The cable bare part should be no more than 8 mm. It is suggested that you can immerse the bare part into the liquid tin. If possible, wear an insulation cap at the end of the bare cable. Make sure there’s no bare copper or cable after the wiring. • The Terminal L and the Terminal N cannot be wired reversely. Do not wire the input and output terminal reversely.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure 2-4 Wire General Device • • • • • • Note The supplied interconnecting cable length is 3.75 m. If you need a longer one, ask our technique supports or sales and purchase for 5.5 m interconnecting cables. The suggested inner diameter of the low voltage conduit is larger than 30 mm. If you want to bury both of the AC power cord and the low voltage cable at the entrance, the two cables should be in separated conduits to avoid interference.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure 2-5 Face Recognition Terminal Wiring • • • • • • Note The supplied interconnecting cable length is 3.75 m. If you need a longer one, ask our technique supports or sales and purchase 5.5 m interconnecting cables. The suggested inner diameter of the low voltage conduit is larger than 30 mm.
DS-K3B501S Series Swing Barrier Quick Start Guide 2.4.2 Slave Control Board Terminal Description The slave lane control board contains interconnecting interfaces, BUS, motor encoder interface, debugging port, door closed position interface, seven-segment display, strip light interface (reserved), supercapacitor, power interface, and motor drive interface. The picture displayed below is the slave control board diagram.
DS-K3B501S Series Swing Barrier Quick Start Guide 2.4.
DS-K3B501S Series Swing Barrier Quick Start Guide Main Controllingn Board Terminal Description RS-485 Interface Power Output 2 RS-232 Interface Power Input Event Input Exit Button Door Lock (Relay) GND Grounding RS-485 B- Connect to Card Reader RS485- RS-485 B+ Connect to Card Reader RS485+ GND Grounding RS-485 C- Connect to Card Reader RS485- RS-485 C+ Connect to Card Reader RS485+ 5V 5 VDC Power Output GND 5 VDC Grounding GND Grounding RS-232 G- Connect to Card Reader RS232- RS-23
DS-K3B501S Series Swing Barrier Quick Start Guide Main Controllingn Board Terminal Description Alarm Output NO/NC1 Alarm Output Relay 1 (Dry Contact) COM1 NO/NC2 Alarm Output Relay 2 (Dry Contact) COM2 NO/NC3 Alarm Output Relay 3 (Dry Contact) COM3 NO/NC4 Alarm Output Relay 4 (Dry Contact) COM4 Network Interface • • • • • • • LAN Network Accessing Note The alarm input hardware interface is normally open by default. So only the normally open signal is allowed.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure 2-6 Main Control Board According to the picture above, the RS-485 serial port corresponds to UART2 and UART3. RS-232 serial port is corresponded to UART7 and UART8. Wiring Interface is corresponded to UART1, UART4, UART6, UART6, and Lane. The main control board descriptions are as follows: UART2/UART3 Jumper Cap Reserved serial port. Use the jumper cap to switch the serial port communication mode.
DS-K3B501S Series Swing Barrier Quick Start Guide UART4 The serial port is in the wiring interface according to the picture above, which has a fixed RS-232 communication mode to communicate with the master lane controller. It contains no jumper cap and cannot change the communication mode. UART7/UART8 Reserved serial port. The serial port has a fixed RS-232 communication mode. It contains no jumper cap and cannot change the communication mode. It can connect QR code scanner, card recycler, and text screen.
DS-K3B501S Series Swing Barrier Quick Start Guide 2.4.5 RS-485 Wiring Note • There are four RS-485 interfaces, which are for connecting ID card reader, IC card reader, QR code scanner, fingerprint and card reader, card recycler, text screen, fingerprint reader, and face recognition terminal. Take the wiring of RS-485 card reader as an example. • For details about text screen, see Configuring Screen Parameters in User Manual of iVMS-4200 AC Client Software.
DS-K3B501S Series Swing Barrier Quick Start Guide 2.4.6 RS-232 Wiring Note • There are three RS-232 interfaces (UART4, UART7, and UART8). UART7 and UART8 can connect QR code scanner, card recycler, and text screen, while UART4 can connect QR code scanner, card recycler, text screen, and face recognition terminal. • For details about text screen, see Configuring Screen Parameters in User Manual of iVMS-4200 AC Client Software. • Take the wiring of text screen as an example.
DS-K3B501S Series Swing Barrier Quick Start Guide 2.4.7 Wiegand Wiring Note Connect the OK/ERR/BZ if the access controller should control the LED and buzzer of the Wiegand card reader. 2.4.8 Barrier Control Wiring By default, the barrier has connected with the main control board. The lane control board can control the barrier status. If possible, the device can connect with a third party lane control board to control the third party barriers.
DS-K3B501S Series Swing Barrier Quick Start Guide Entering Wiring Exiting Wiring 17
DS-K3B501S Series Swing Barrier Quick Start Guide 2.4.9 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) . 2.4.10 Fire Alarm Module Wiring You can view the fire alarm module wiring diagram.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure 2-8 Fire Alarm Module Wiring 19
DS-K3B501S Series Swing Barrier Quick Start Guide Chapter 3 Installation 3.1 Disassemble Pedestals Before installation, you should use the key to open the pedestals. View the pictures below to find the lock holes. Figure 3-1 Lock Holes 3.2 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base. Steps Note • The device should be installed on the concrete surface or other non-flammable surfaces.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure 3-2 Dimension 1. Prepare for the installation tools, check the components, and prepare for the installation base. 2. Draw a central line on the installation surface of the left or right pedestal. 3. Draw other parallel lines for installing the other pedestals. Note The distance between the nearest two line is L+200 mm. L represents the lane width. 4.
DS-K3B501S Series Swing Barrier Quick Start Guide 7. Secure the pedestals with expansion bolts. Note • Do not immerse the pedestal in the water. In special circumstances, the immersed height should be no more than 150 mm.
DS-K3B501S Series Swing Barrier Quick Start Guide Chapter 4 Device Settings After installation and wiring completed, you should set the barriers closed position (study mode) before entering the working mode. You can also set the test mode, normal mode, passing mode and memory mode, pair the keyfob, initialize the hardware, switching between RS-485 communication mode and RS-232 communication mode, and view relay output NO/NC diagram by setting the DIP switch on the main control board.
DS-K3B501S Series Swing Barrier Quick Start Guide 6. Power on the device again. Note For details about the DIP switch value and meaning, see DIP Switch Description. The barrier will open automatically and turns back to the closed position. At this circumstance, the device enters the normal mode. 4.2 Pair Keyfob (Optional) Pair the remote control to the device through DIP switch to open/close the barrier remotely. Before You Start Ask our technique supports or sales and purchase the keyfob. Steps 1.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure 4-1 Initialization Jumper Cap 2. Disconnect the power and reboot the device. The device buzzer buzzes a long beep. 3. When the beep stopped, plug the jumper cap back. 4. Disconnect the power and power on the device again. Caution The initialization of the device will restore all the parameters to the default setting and all the device events are deleted. Note Make sure no persons are in the lane when powering on the device. 4.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure 4-3 Jumper Cap Status of RS-232 Interface 4.5 Switch Relay Output Mode (NO/NC) 4.5.
DS-K3B501S Series Swing Barrier Quick Start Guide 4.5.
DS-K3B501S Series Swing Barrier Quick Start Guide Chapter 5 Activation You should activate the device before the first login. After powering on the device, the system will switch to Device Activation page. Activation via the device, SADP tool and the client software are supported. The default values of the device are as follows: • The default IP address: 192.0.0.64 • The default port No.: 8000 • The default user name: admin 5.
DS-K3B501S Series Swing Barrier Quick Start Guide Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP. 3) Input the admin password and click Modify to activate your IP address modification. 5.
DS-K3B501S Series Swing Barrier Quick Start Guide three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. Proper configuration of all passwords and other security settings is the responsibility of the installer and/or end-user. 7.
DS-K3B501S Series Swing Barrier Quick Start Guide Appendix A. Tips for Scanning Fingerprint Recommended Finger Forefinger, middle finger or the third finger. Correct Scanning The figure displayed below is the correct way to scan your finger: You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center.
DS-K3B501S Series Swing Barrier Quick Start Guide Others If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other authentication methods. If you have injuries on the scanned finger, the scanner may not recognize. You can change another finger and try again.
DS-K3B501S Series Swing Barrier Quick Start Guide Appendix B. DIP Switch B.1 DIP Switch Description The DIP switch is on the master lane control board. No.1 to No 8 is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12. B.
DS-K3B501S Series Swing Barrier Quick Start Guide Bit Device Mode Function Decimal Value Binary Value Controlled 2 Entrance and Free Exit 0010 Free Bi-direction 3 0011 Free Entrance and 4 Controlled Exit 0100 Free Entrance and 5 Prohibit Exit 0101 Prohibited Bidirection 6 0110 Prohibit Entrance 7 and Controlled Exit 0111 Prohibit Entrance 8 and Free Exit 1000 34
DS-K3B501S Series Swing Barrier Quick Start Guide Appendix C.
DS-K3B501S Series Swing Barrier Quick Start Guide Appendix D. Table of Audio Index Related Content Index Content 1 Authenticated. 2 Card No. does not exist. 3 Card No. and fingerprint mismatch. 4 Climbing over the barrier. 5 Reverse passing. 6 Passing timeout. 7 Intrusion. 8 Force accessing. 9 Tailgating. 10 No permissions. 11 Authentication time out. 12 Authentication failed. 13 Expired card.
DS-K3B501S Series Swing Barrier Quick Start Guide Appendix E. Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number.
DS-K3B501S Series Swing Barrier Quick Start Guide Error Reason Code Error Reason Code The Third IR Beam on Lower IR 15 Board Triggered Lower IR Board 8 Offline 44 The Fourth IR Beam on Lower IR Board Triggered 16 Lower IR Board 9 Offline 45 The Fifth IR Beam on Lower IR Board Triggered 17 Lower IR Board 10 Offline 46 The Sixth IR Beam on Lower IR Board Triggered 18 Lower IR Board 11 Offline 47 The Seventh IR Beam on Lower 19 IR Board Triggered Lower IR Board 12 Offline 48 The Eighth IR
DS-K3B501S Series Swing Barrier Quick Start Guide Appendix F. Communication Matrix and Device Command Communication Matrix Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices. Figure F-1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands.
DS-K3B501S Series Swing Barrier Quick Start Guide Figure F-2 Device Command 40
UD18740B