User's Manual

DS-PR1-60
Security Radar
Diagram References
ENGLISH
Indictaor
Installaon
For detailed sengs, Scan the QR code to get the User Manual of Security Radar.
1. Download and install the iVMS-4200 client soware.
2. Enter Control Panel
- Modules Customizaon, select Radar, and click OK.
3. Enter Device Management page, select the radar in the Online Device List, click Modify
Nenfo, change the port as 80, and click Add to Client. If the network of the radar
is not the same as the PCs, click Add
in the Device for Management list and enter the radar
IP address in the pop-up window to add the radar.
4. In iVMS-4200 client soware, enter Control Panel - Radar
.
5. Upload Map: Select a map, enter the actual width (m) and height (m) of the map.
6. Expand the device group in the list on the le, and click and drag the detector onto the map.
7. Move along the edge of the required monitoring filed. Make sure the target sign (red arrow)
is moving withhin the radar area (gray sector) shown on the added map. If the target sign is not
within the sector, you need to adjust the mounng posion or angle of the radar.
Power on the radar and make sure there is no large object in the monitoring area. Make the
detector access into the internet.
Test the radar aer installaon to make sure it is properly mounted.
1. In iVMS-4200 client soware, select the radar on Device Manegement page and click
Remote Configuraon to enter the configuraon page. You can also enter the device IP
address in the web broswer to enter the configuraon page.
2. Click Smart Rule Sengs - Camera Linkage Sengs.
3. Click
+ to add cameras to the radar.
4. Select a camera in the Camera IP Address List, and select a radar zone (or whole field) in the
Zone Linkage list.
5. Add the camera to iVMS-4200 client soware: In the client soware, enter Device
Management page, click Add
in the Device for Management list, and enter the IP address, user
name and password of the camera in the pop-up window.
1. Select a reference object about 50 m away from the speed dome. On the reference object,
select a point whose altude is the same as the speed dome’s.
2. Enter the IP address of the speed dome in the web broswer to enter the web client. Adjust
the PTZ buons on the Live View page to make the reference object displayed in the image,
and Click to zoom in the reference object.
3. Click , and click the reference point to middle the point in the frame.
4. Enter Configuraon - PTZ - Inial Posion, and click Set to set the inial posion.
Link the camera to the Zone
Before calibraon, set the inial posion of the speed dome to ensure the tracking accuracy.
1. In iVMS-4200 client soware, enter Radar page, click
...
- Master-Slave Tracking Sengs.
2. Double click the radar in the list on the le. Click the live view window of the speed dome
needs to be calibrated, and click to maximum the window.
3. Select One Point Calibraon
as the calibraon mode.
4. Click Add
to add a calibraon point.
5. Ask the calibraon staff to move in the radar detecon field. Click the track of the calibrate
staff, and the color of the selected track will change from red to yellow.
6. Ask the calibraon staff to stand at the calibraon point within 20 to 40 m directly in front
of the radar.
7. Click the added calibraon point in the list on the right to update the radar posion of the
calibraon staff.
8. Adjust the PTZ buons in the live view window to update the PTZ posion: Click +/- to scale
the calibraon staff to a fit size (The altude of the calibraon staff is about 2/3 of the altude
of the window), and adjust the PTZ to make the object align with the sign + at the center of
the frame. (For precise alignment, click , and click on the center of the calibraon staff.)
9. Click Save
.
Calibrate the Speed Dome
Calibraon
Inial Posion sengs
Enable Speed Dome Tracking
In iVMS-4200 client soware, enter the Master-Slave Tracking Sengs page, select the live
view window of the speed dome, and Check Enable Tracking.
Test
1
4
Wiring
3
Formang
2
5
Set Up
6
Specification
1. Aach the mounng bracket on the detector with four supplied screws.
2. Loosen the screws on both side of the bracket.
3. Adjust the angle of the detector.
4. Tighten the screws on the both side of the bracket to complete the installaon.
1. Aach the mounng bracket on the detector with four supplied screws.
2. Loosen the screws on both side of the bracket.
3. Adjust the angle of the detector.
4. Tighten the screws on the both side of the bracket to complete the installaon.
a. Power Supply Indicator
Solid Green: Detector Power on
b. Fault Alarm Indicator
Flashing Red: Fault Alarm Occurred, Solid
Green: Alarm Restored
c. Zone Alarm Indicator
Solid Red: Zone Alarm Occurred, Solid
Green: Alarm Restored
d. Formang Indicator
Flashing Red: Formang Successfully
a. Alarm Output Wiring (Dry Contact Output)
a1: One Strong Current Output
a2: Three Weak Current Output
b. Alarm Input Wiring (Reserved)
c. Power Supply Wiring
d. Network Wiring (supports PoE)
e. Grounding
Loosen the screws on the rear cover to
remove the cover. Hold the Reset buon
while powering the radar on unl the red
and green LED flashes.
Ceiling Mounng
Pole Mounng
Before You Start:
The recommended installaon height is 2.5 m.
Make sure that the mounng surface is strong enough to withstand at least 50N, as well as
four mes the weight of the device and the bracket.
1. In iVMS-4200 client soware, enter Control Panel - Radar.
2. Click
...
- Draw Zone Manually, and click the mouse to draw a zone on the radar detecon
area. The system will pop up the zone sengs window 3s aer the drawing being completed.
3. Edit the zone parameters in the pop-up window.
4. Oponal: You can also click
...
- Draw Zone Automacally, and walk in the radar detecon filed
by a closed-loop path to draw a zone. For detailed, refer to
the User Manual of Security Radar.
Add Zone for the Detector
If the speed dome is installed together with the radar, select the calibraon mode as One Point
Calibraon. Otherwise, set the calibraon as Mulpoint Calibraon.
For one point calibraon, you can refer to the following steps, and see user manual for mulpoint
calibraon.
Note: You should acvate the device for the first usage. Select the device in the Online
Device List, click Acvate, create a password to acvate the device.
Scan the QR code to get the User Manual of Security Radar.
Note: Zones are not allowed to overlap.
Before the operaon, you need to click on the Radar
page to disarm the radar.
1
1
2
2
3
4
Use only power supply listed below:
Manufacturer: Shenzhen HONOR Electronic Co., Ltd.
ModelADS-26FSG-12 12024EPG
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
ALL RIGHTS RESERVED.
Any and all informaon, including, among others, wordings, pictures, graphs are the properes of Hangzhou Hikvision Digital Technology Co., Ltd. or its
subsidiaries (hereinaer referred to be “Hikvision”). This user manual (hereinaer referred to be “the Manual”) cannot be reproduced, changed,
translated, or distributed, parally or wholly, by any means, without the prior wrien permission of Hikvision. Unless otherwise spulated, Hikvision
does not make any warranes, guarantees or representaons, express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to the Security Radar.
The Manual includes instrucons for using and managing the product. Pictures, charts, images and all other informaon hereinaer are for descripon
and explanaon only. The informaon contained in the Manual is subject to change, without noce, due to firmware updates or other reasons. Please
find the latest version in the company website (hp://overseas.hikvision.com/en/).
Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement and other Hikvision’s trademarks and logos are the properes of Hikvision in various jurisdicons.
Other trademarks and logos menoned below are the properes of their respecve owners.
Product Informaon
This product and - if applicable - the supplied accessories
too are marked with "CE" and comply therefore with the
applicable harmonized European standards listed under the
RE Direcve 2014/53/EU, the EMC Direcve 2014/30/EU,
the LVD Direcve 2014/35/EU, the RoHS Direcve
2011/65/EU.
2012/19/EU (WEEE direcve): Products marked with this
symbol cannot be disposed of as unsorted municipal waste in
the European Union. For proper recycling, return this product
to your local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collecon points.
For more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery
that cannot be disposed of as unsorted municipal waste in the
European Union. See the product documentaon for specific
baery informaon. The baery is marked with this symbol,
which may include leering to indicate cadmium (Cd), lead
(Pb), or mercury (Hg). For proper recycling, return the baery
to your supplier or to a designated collecon point. For more
informaon see:www.recyclethis.info
1 3
4
6
206.5
228.5
60.8
2
a
b
c
d
NC
NO
……
……
NO COM NC
NO COM NC
a
1
2
a
b
c
d
OSD
2
4
1 2
50 m
09-29-2018 16:50:20
+
+
3D
3D
09-29-2018 16:51:22
09-29-2018 16:51:22
+
H H=h h
Initial Position
09-29-2018 16:52:07
a
b
NO4
NC4
COM4
NO3
NC3
COM3
NO2
NC2
COM2
NO1
NC1
COM1
e
Model DS-PR1-60
Detection Range 60 m
Horizontal Angle 100°
Detection Area About 3000
Max. Target Number 32
Velocity Range -8.7 to 8.7 m/s
Range Measurement
Accuracy
±0.75 m
V
elocity Measurement
Accuracy
±0.1 m/s
A
ngle Measurement
Accuracy
±1°
Zone 8
3-ch weak current output: 0.5
A/125 VAC,breakdown voltage: 1
KV
1-ch strong current output: 10
A/240 VAC,breakdown voltage:
2.5 KV
A
larm Output
UD13647B
Netowrk Interface
1 RJ45 10M/100M self-adaptive,
supports POE
Communication
Protocol
Standard ISAPI protocol, NAL2300
protocol
HTTP, DNS, NTP, TCP, UDP, DHCP,
ARP, and SSH
Exception Detection
Cover and Wall tamper-proof, and
blocking alarm
Power Interface
802.3at standard POE or 12 VDC
The supplied power adapter is for
12 VDC power input.
Operation Temperature –40 to 65
Operation Humidity 10% to 90%
Dimension(W x H x D) 206*228*61 mm
IP Level IP67
Weight 1.84 kg
Installation
Bracket installation
Installation Height: 1.2 m to 4 m
Recommended height range: 2.5 m
Recommended vertical angle: 0°
OSD
!
!
!
1 (-24.29,42) (12,25,34)
1 (-19.79,34) (31,43,17)
a
b
Note: The track disappears if the calibraon staff is standing in place for more than 5 s. If the
calibraon staff does not move to the calibraon point when the track disappears, you need
to ask the calibraon staff moves again, and click the track of the calibraon staff to connue
the calibraon.
Before the operaon, you need to click on the Radar page to disarm the radar, and link
the speed dome to the zone.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the instruc
ons, may cause harmful interference to radio
communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful
interference to radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
FCC Warning:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon
This product operates in a European non-harmonised
frequency band.

Summary of content (1 pages)