(2)After the device is connected to the network, users can rename or share the device.
Note
1. Make sure the Zigbee Gateway and smartphone are on the same network
when adding devices (2.4g only)
2. Ensure that the Zigbee gateway is compatible with the added
temperature and humidity sensor
7.
DATA ACQUISITION
(1)Click the button to activate the device and it samples and sends data
(2)Report temperature and humidity value every 30 minutes
( 3 )Temperature and humidity data will be collected every 5 minutes. If the temperature
difference is greater than 0.6℃ or the humidity difference is greater than 6%, relevant data will
be separately reported.
(4)Offline:No data collection
(5)Out of network:Battery power will not be collected or reported, and the device will be fully
dormant
(6)First addition to the network, it will report full battery about 5s later. And then the real battery
status will be reported again about 5 minutes later. Finally, the battery status will be reported every
4h.
(7)The battery level of the product will be measured when it is powered on and when it is woke
up.When the power is below the configuration value (2.4V), low battery alert will be sent;