User Guide

IS151-R5 12/02
www.hannainst.com
These Instruments are in
Compliance with the CE Directives
Instruction Manual
Checktemp 4
(HI 151-00 and HI 151-01)
Rugged Folding
Thermometers
HI 151-00
Range -50.0 to +220°C
Resolution 0.1°C (-50.0 to 199.9°C), 1°C (200 to 220°C)
Accuracy ±0.4°C±1 digit (-20.0 to 90.0°C);
(@25ºC/77ºF) ±1% f.s.±1 digit (outside)
Typical EMC Deviation ±0.3°C
HI 151-01
Range -58.0 to +428°F
Resolution 0.1°F (-58.0 to 199.9°F), 1°F (200 to 428°F)
Accuracy ±0.8°F±1 digit (-4.0 to 194.0°F);
(@25ºC/77ºF) ±1% f.s.±1 digit (outside)
Typical EMC Deviation ±0.6°F
Common specifications
Probe Stainless steel sharp probe (117 x 3.5 mm)
Calibration In factory only
Battery Type/Life 1x1.5V AA / 25.000 hours of continuous use
Auto-off after 5 minutes
Dimensions 165x50x20 mm (6.5 x 2.0 x 0.8”)
Weight 100 g (3.6 oz)
SPECIFICATIONS
HI 151-00 and HI 151-01 are warranted for one year against defects in workmanship and
materials when used for its intended purpose and maintained according to instructions. This
warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instrument. If under
warranty, report the model number, date of purchase, serial number and the nature of the
failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If
the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authoriza-
tion Number from the Customer Service department and then send it with shipment costs prepaid.
When shipping any instrument, make sure it is properly packaged for complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright
owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.
WARRANTY
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of
these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. Any variation introduced
by the user to the supplied equipment may degrade the instrument’s EMC performance. To avoid electrical shock, do not use
these instruments when voltages at the measurement surface exceed 24 VAC or 60 VDC. To avoid damages or burns, do not
perform any measurement in microwave ovens.

Summary of content (2 pages)