Instruction Manual HI 9041 • HI 9061 HI 93501 • HI 95502 HI 93503 HI 935007 Portable Microprocessor Thermometers w w w . h a n n a i n s t .
Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the instrument. This manual will provide you with the necessary information for correct use of the instrument, as well as a more precise idea of its versatility. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com. These instruments are in compliance with the directives.
SPECIFICATIONS OF HI 9041C & HI 9041F SPECIFICATIONS OF HI 9061C & HI 9061F Main features: Main features: • • • • • • • • • HI 765 probes series Available HI 765 accuracy test plugs Remaining battery life indication / low battery detection Available in °C or °F models Range Resolution Accuracy Typical EMC Deviation Probe Battery Environment Dimensions Weight HI 9041 -50.0 to 150.0°C (HI 9041C) -58.0 to 302.0°F (HI 9041F) 0.1°C / 0.1°F ±0.4°C / ±0.8°F excluding probe error ±0.
SPECIFICATIONS OF HI 93501 SPECIFICATIONS OF HI 95502 Main features: Main features: • • • • • • • • • • • • • • HI 762 probes series Available HI 762 accuracy test plugs Range -50 to 150°C Calibration Check feature Remaining battery life indication / low battery detection Auto-off capability Waterproof casing LUMBERG® socket for temperature probes LUMBERG® probes series Range -50 to 150°C Calibration Check feature Remaining battery life indication / low battery detection Auto-off capability Waterproo
SPECIFICATIONS OF HI 93503 SPECIFICATIONS OF HI 935007 Main features: Main features: • • • • • • • • • • • • • HI 765 probes series Available HI 765 accuracy test plugs Range -50 to 150°C Calibration Check feature Remaining battery life indication / low battery detection Auto-off capability Waterproof casing SPECIFICATIONS Range -50.0 to 150.0°C Resolution 0.1°C Accuracy ±0.4°C excluding probe error Typical EMC Deviation ±0.4°C (with HI 765PWL probe) Battery 3x1.
OPERATIONAL GUIDE Each meter is supplied complete with batteries. Remove the back cover, unwrap the supplied batteries and install them while paying attention to their polarity (see also the "Battery replacement" section for more details). Note: HI 93501, HI 95502, HI 93503 and HI 935007 come with batteries already installed. TAKING MEASUREMENTS Connect a suitable temperature probe to the meter (see pages 14-15 for a complete list of Hanna probes). Note: HI 935007 has a fixed probe.
using the battery type specified in this instruction manual. • HI 9041 and HI 9061: remove the battery cover and replace the batteries (1x9V for HI 9041 or 4x1.5V AA for HI 9061) with new ones, while paying attention to their polarity. Reattach the battery cover. FACTORY RECALIBRATION All Hanna thermometers have been accurately pre-calibrated at the factory. It is generally recommended to have all thermometers recalibrated at least once a year.
TEMPERATURE PROBES Hanna offers a wide range of probes to meet your needs with air, liquid, penetration and surface measurements. All Hanna temperature probes are pre-calibrated at the factory and ready-to-use. These interchangeable probes make it possible to switch from one probe to another without requiring recalibration. Hanna probes are also available in different handle colors to avoid cross contamination during testing.
SALES AND TECHNICAL SERVICE CONTACTS Australia: Tel. (03) 9769.0666 • Fax (03) 9769.0699 China: Tel. (10) 88570068 • Fax (10) 88570060 Egypt: Tel. & Fax (02) 2758.683 Germany: Tel. (07851) 9129-0 • Fax (07851) 9129-99 Greece: Tel. (210) 823.5192 • Fax (210) 884.0210 Indonesia: Tel. (21) 4584.2941 • Fax (21) 4584.2942 Japan: Tel. (03) 3258.9565 • Fax (03) 3258.9567 Korea: Tel. (02) 2278.5147 • Fax (02) 2264.1729 Malaysia: Tel. (603) 5638.9940 • Fax (603) 5638.9829 Singapore: Tel. 6296.