9. Restore your gas supply and check ALL of the connections for leaks using a solution of
soapy water. If a leak is discovered and any bubbles are seen, close the main gas valve and
re-tighten ALL the connections. NEVER USE A FLAME TO CHECK FOR GAS LEAKS!
Step5
10. Stick the conversion label on the rating plate as shown in Figure 5.
Metal Rating Plate
1.
2.
3.
4.
5.
6.
7.
Figure 17 Conversion Label
MAINTENANCE
The flames should look like those in Figure 6. To clean the
burner, use a soft brush after the burner has cooled
completely. Never use a vacuum cleaner on the burner. It is
recommended to store the fire pit indoors during winter if it
will be subjected to freezing temperatures. The LP cylinder
must be disconnected and removed from the appliance
before the appliance can be stored indoors.
Figure 6
Serial Number _________________ Model Number: WT17ZL4
CAUTION: The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of
Minimum clearance from combustible constructions: Sides: 24 in.609 mm. Top 72 in. 1828 mm.
FOR OUTDOOR USE ONLY. If stored indoors, detach and leave cylinder outdoors.
This appliance has been converted to use Natural Gas. Input 40,000 Btu/hr.
Max Gas Supply Pressure 7 inch w.c. (1.74 kPa) Min. Gas Supply Pressure 5 inch w.c. (1.24 kPa)
Fi
g
ure 5
Conversion Label