Use and Care Manual

2. Push in the igniter button. You will hear a slight clicking sound. With the igniter button
pushed in, push and turn the control knob to the “ON” position. The fire should light within a
few seconds. Once the flame is lit, release the igniter button and continue to hold the control
knob in for 10 to 15 seconds. Release the control knob. The control knob should pop back out
and then the fire remain lit. Note: If the fire does not light, turn the knob to the “OFF” position
and wait five (5) minutes before trying again.
3. To turn down the flame, push the control knob in slightly and turn to Medium (medium
flame), or Low (small flame).
4. To shut down the fire pit, turn the control knob to the “OFF” position and turn off the tank
valve.
TROUBLESHOOTING GUIDE
PROBLEM CAUSE REMEDY
No propane gas at burner
Check that gas tank valve is open.
Turn control knob to “ON” and push
control knob in. Make sure tank has
propane gas.
No spark at electrode
Check that AA battery is installed
with negative (-) end first and has a
charge. Check that the wire is
connected to the ignition module.
Check that the electrode is not
cracked or broken.
Burner won’t light
Lack of oxygen
Remove excess fire ice from around
the ignition well.
Thermocouple not in flame
Check that the tip of the
thermocouple is even with the top of
the ignition well. Remove any fire ice
from the ignition well.
Thermocouple connection
at the main control valve is
loose
Tighten the thermocouple nut at the
back of the valve.
Burner won’t stay
lit after lighting
No fire ice on burner
Cover the burner with fire ice per the
instructions.
Page ̐
13