Installation Instructions / Warranty Raindance Showerpanel 27005XX1
Raindance Showerpanel 27005XX1
Technical Data Operating pressure: max.145 psi Recommended pressure: 30 - 60 psi Test pressure: 232 psi Max. hot water temp.: 176° F* Recommended hot water temp.: 120°F - 140°F* Flow rate @ 45 psi Handshower Bodysprays 2.5 gpm <1 gpm each Protection against back siphonage is provided by check valves in the hot and cold supply elbows. This panel incorporates a thermostatic mixing valve. The high temperature limit stop on the mixing valve can be reset to comply with local plumbing codes. See page 10.
Preparation for Installation Install 1/2” IPS nipples for the hot and cold water supplies at the locations shown on the diagram. The nipples should extend 5/8” outside the surface of the finish wall. For proper operation of the unit, the hot supply should be on the left, and the cold supply should be on the right. Install the wall surface material. Make sure that the wall is watertight before installing the panel. Seal the wall around the nipples with waterproof sealant.
Installation Wrap the nipples with several layers of Teflon tape. Install the elbows included with the panel. The outlets should point downwards. The elbow should extend no more than 1 1/4” from the surface of the finished wall. With a helper holding the panel in place, mark the positions of the screw holes. Set the panel aside, securely supported to prevent damage.
Drill the screw holes with a 6 mm bit suitable for the wall surface. Install the anchors. Seal the wall around the anchors with waterproof sealant. Hold the panel against the wall. Install the gray plastic insert. Insert the top screw through the front of the panel, the washer and the insert. Screw it into the anchor.
Install the center and bottom screws and washers. Connect the supply hoses to the hot and cold supply elbows. Connect the supply hoses to the hot and cold inlet ports on the valve. Turn the water on at the main. Push the diverter stem up to turn the water on to the panel. Check all connections for leaks.
Once you ensure that the connections are watertight, push the diverter stem down to turn the water off to the panel. Install the side seals on the front cover. Trim off any excess. Push the front cover into place. Install the diverter sleeve. Make sure that the indexing mark on the thermostatic mixer sleeve is at the 12:00 position. Install the thermostatic mixer handle. Tighten the handle screw with a flat-bladed screwdriver.
Install the diverter handle. Tighten the set screw with a 4 mm Allen wrench. Place a black rubber washer in one end of the handshower hose. Screw this end of the hose to the handshower outlet port. Place the screen washer in the other end of the hose. Screw this end of the hose to the handshower. Place the handshower in the holder. Adjust the Slider You can make the slider easier or harder to move. Use a 2.
Justify the Thermostatic Mixer Handle Turn the water on to the handshower. Turn the thermostatic mixer handle until the output water measures 100o on a thermometer. Turning the handle clockwise makes the water cooler, counter-clockwise makes the water warmer. Loosen the thermostatic mixer handle screw. Remove the handle. Turn the water off. Set the High Temperature Limit Stop (optional) Remove the thermostatic mixer handle. Remove the clip and the stop ring from the stem of the thermostatic mixer.
Turn the water on to the handshower. Turn the temperature control stem until the output water is the desired maximum high temperature -- usually 110o*. Turn the water off. *Please know and follow all applicable local plumbing codes when setting the high temperature limit stop. Replace the stop ring so that the tooth is against the high temperature limit stop. Replace the clip. Justify the handle. User Instructions Using the Thermostatic Mixer Turn the handle clockwise to make the water cooler.
Using the Diverter Pull the lever upward to turn the water on. Pivot the handle to the desired function.
Using the 3-Jet Handshower To change spray modes, push the selector lever until the desired spray is achieved. selector lever Rain AIR Balance AIR Whirl AIR Scale Removal The Raindance Air 3-jet handshower incorporates the RubitTM cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub the spray channels with a finger or a sponge.
Rinse the handshower with clear water. Reinstall the handshower. Turn on the water and allow the handshower to flush for at least one minute.
Troubleshooting Problem Possible Cause Remedy Insufficient water - Supply pressure inadequate - Check water pressure (If a pump has been installed, check to see if the pump is working).
4 2 1 3 5 20 22 6 21 13 12 18 11 23x2 29x2,5 25x2 17 10 16 6 15 14 8 6 9 19 16 7
Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 handshower 28519XXX slider 97024XXX handshower hose, 63” 28276XXX upper cover 97324000 escutcheon 97326000 body shower 28406000 diverter handle 10490XXX thermostatic mixer handle 38391XXX flange 97858XXX front cover 97859000 sleeve 95032XXX adapter for handle 97108000 thermostat cartridge 94282000 nut 96945000 diverter cartridge 96645000 sealing set 95037000 connection hose 13099001 fixing set for hose con
Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets, kitchen faucets, and showers consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain criteria when cleaning.
including, without limitation, a commercial purpose, this warranty extends only (i) for 1 year, with respect to Hansgrohe and Commercial products, and (ii) for 5 years, with respect to AXOR products. THIS WARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT PAY FOR: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B.
www.hansgrohe-USA.com US - Installation Instructions • Part No. 90402321 • Revised 08/2007 Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 Tel.