Faucet Installation Instruction

11/04
HANSGROHE PRODUCT SERVICE
Assembly
Turn on by lifting handle.
Swivel to the left: hot water
Swivel to the right: cold water.
Large differences in pressure between the hot and cold water supply should be balanced.
1. Flush pipe lines thoroughly.
2. Place the mixer including the rubber sealing washer in position on the basin.
3. Slip the mounting nut including the washer over the threaded pin and tighten the nut.
4. Connect the supply pipes to the supply valves: hot-left; cold-right.
5. Connect the pop-up rod to the pop-up waste assembly.
Operation
Operating pressure : max. 147 psi
Recommended operating pressure : 14.7 - 72.5 psi
Test pressure : 232 psi
Hot water temperature : max. 176° F
Recommended hot water temperature : 149° F
Technical data
Lav mixer 37001XX1
SINGLE LEVER LAV MIXER
SINGEL LEVER BIDET MIXER
SINGLE LEVER LAV MIXER Highriser
Ref. No.: 37001XX1/37200XX1/
37020XX1/37028XX1
Installation
Terrano
Bidet mixer 37200XX1
Hole size in basin:
Minimum: 1 1/4"
Maximum: 1 5/8"
Lav mixer Highriser 37020XX1
Lav mixer Highriser 37028XX1 without
lift rod and pop-up waste
hot cold