User's Manual

Installation guidelines
3 – 6 D101583 0207 BL ident
No mounting of the data carrier directly on metal
The data carriers (with the exception of high temperature data
carriers) may not be mounted directly on metal. Non-metallic
spacers (see chapter 9, Accessories) enable mounting which does
not lead to an interruption of the functions (Fig. 6).
The data carriers may not be mounted so that the necessary
minimum distance to metal and to the data carriers around them is
less than the minimum distance. The minimum distance is
dependent on the housing design of the read-write head; a = 10 mm
around the data carrier can be assumed (Fig. 7). The high
temperature data carrier (see page 5 - 2, table 1) can be constructed
so that it can be mounted directly on metal without the need for
additional measures.
Figure 6
Installation with
spacers
Figure 7
Installation
considering the
minimum distance
from metal
h
metal
non-metallic spacer
data carrier
a