Product Manual

Hanshow ESL Controller HS_C09978 Product Manual
8 Hanshow Copyright Reserved ©
Hanshow Technology Co., Ltd.
3 Installation
The USB integration AP supports the following four installation modes:
Horizontal hanging suspension from the ceiling
Wall mounting
Threaded hanger mounting
Cross bar mounting
The installation height may be affect AP wireless coverage. Generally, HS_C09978 is
installed in a higher position to achieve better transmission and coverage, as shown in
Figure 3-1.
Figure 3-1 HS_C09978 installation diagram
Recommended installation scenarios are as follows:
If the shelf height is 3m, H in Figure 3-1 is recommended to 3m ~ 5m, and the
coverage radius R is 10m ~ 13m. It is recommended that the radius R is 10m,
installation distance of two Hanshow APs is about 22m, and at least 5m.
If the shelf height is 3m ~ 5m, H in Figure 3-1 is recommended to 5m ~ 8m, and the
coverage radius R is 7m ~ 10m. It is recommended that the installation distance of
two Hanshow APs is about 18m and at least 5m.
If the shelf height exceeds 5m, the AP installation height needs to be determined
according to actual situation of on-site engineering result.