Product Manual
Table Of Contents
Hanshow ESL Controller HS_C09978 Product Manual
24 Hanshow Copyright Reserved ©
Hanshow Technology Co., Ltd.
Item
Description
Installation distance
⚫ If the shelf height is ≤3m, recommended the installation distance
of two Hanshow APs is about 22m, and at least 5m.
⚫ If the shelf height is 3m ~ 5m, it is recommended that the
installation distance of two Hanshow APs is about 18m and at least
5m.
⚫ If shelf height exceeds 5m, the installation height of AP is
determined according to the actual situation.
⚫ The installation height of AP should be higher than shelf height to
avoid signal occlusion.
⚫ For Horizontal hanging suspension from the ceiling, recommended
the installation distance is more than 6cm away from the ceiling.
Network settings
⚫ Wi-Fi AP 5GHz frequency band is suggested to replace 2.4GHz
frequency band for Wi-Fi coverage.
⚫ If Wi-Fi AP is 2.4GHz, recommended to set Wi-Fi channel to 1, 6
or 11.
⚫ If Wi-Fi AP is 2.4GHz, recommended to stagger the update time
with ESLs to achieve optimal performance.
⚫ Hanshow AP may be limited or affected by other IoT devices that
share the 2.4GHz frequency-band such as Wi-Fi, BT or Zigbee.
Post-installation check
⚫ Install the AP firmly on the ceiling to avoid AP falling off and
damaged.
⚫ The power cable or network cable is intact and not spliced.
⚫ The AP runs properly.