Description
Installation distance
If the shelf height is 3m, recommended the installation distance
of two Hanshow APs is about 22m, and at least 5m.
If the shelf height is 3m ~ 5m, it is recommended that the
installation distance of two Hanshow APs is about 18m and at least
5m.
If shelf height exceeds 5m, the installation height of AP is
determined according to the actual situation.
The installation height of AP should be higher than shelf height to
avoid signal occlusion.
For Horizontal hanging suspension from the ceiling, recommended
the installation distance is more than 6cm away from the ceiling.
Network settings
Wi-Fi AP 5GHz frequency band is suggested to replace 2.4GHz
frequency band for Wi-Fi coverage.
If Wi-Fi AP is 2.4GHz, recommended to set Wi-Fi channel to 1, 6
or 11.
If Wi-Fi AP is 2.4GHz, recommended to stagger the update time
with ESLs to achieve optimal performance.
Hanshow AP may be limited or affected by other IoT devices that
share the 2.4GHz frequency-band such as Wi-Fi, BT or Zigbee.
Post-installation check
Install the AP firmly on the ceiling to avoid AP falling off and
damaged.
The power cable or network cable is intact and not spliced.
The AP runs properly.