ITEM #0747609 THOROUGHBRED CEILING FAN Harbor Breeze® is a registered trademark of LF, LLC. All Rights Reserved. MODEL #TEX52MBK5C1L Español p. 22 LISTED ATTACH YOUR RECEIPT HERE Serial Number E192641 Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-643-0067, 8 a.m. - 6 p.m., EST, Monday - Thursday, 8 a.m. 5 p.m., EST, Friday. EB15437 Lowes.
TABLE OF CONTENTS Safety Information .............................................................................................................. 2 Package Contents .............................................................................................................. 4 Hardware Contents ............................................................................................................ 5 Preparation ...........................................................................................
SAFETY INFORMATION WARNING To reduce the risk of fire, electrical shock or personal injury, mount fan to outlet box marked "ACCEPTABLE FOR FAN SUPPORT OF 35 LBS. OR LESS" and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
PACKAGE CONTENTS B T A C E P D AB Q F O G V N H S Y Z X U R W I J K L M PART A B C D E F G H I J K L M N O P Q R DESCRIPTION QUANTITY Downrod 1 Mounting Bracket 1 Canopy 1 Canopy Cover 1 Yoke Cover 1 15-watt Bulb 4 (preassembled) Motor Housing 1 Switch Housing Plate 1 Light Kit Fitter 1 Glass Shade 1 Finial Plate (preassembled) 1 Threaded Washer 1 (preassembled) Finial (preassembled) 1 Blade Arm Blade S T U V W X Y Z 5 5 AB IMPORTANT REMINDER: You must use the parts provided with this
HARDWARE CONTENTS (shown actual size) AA BB Blade Screw Blade Washer Qty. 15 + 1 extra Qty. 15 + 1 extra CC CC DD Cap Wire Connector Qty. 1 Qty. 4 PREPARATION Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.
INITIAL INSTALLATION 2. Determine mounting method to use. A. Standard mount B. Angle mount IMPORTANT: If using the angle mount, ensure the ceiling angle is not steeper than 19°. 2 *Helpful Hint: Standard mounting is best suited for ceilings 8 ft. high or higher. For taller ceilings you may want to use a longer downrod (not included). Angle mounting is best suited for angled or vaulted ceilings. A longer downrod is sometimes necessary to ensure proper blade clearance. A 19° max. B 3.
INITIAL INSTALLATION 5. Remove motor screws (R) and lock washers (S) from underside of motor housing (G) and save for later on. Note: If there are plastic motor blocks installed with the motor screws (R) and lock washers (S), discard the plastic motor blocks. 5 R S G FAN MOUNTING 1. Remove pin (P) and clip (Q) from yoke at top of motor housing (G) and partially loosen preassembled set screws and nuts. 1 Set Screws and Nuts Yoke Q P G 2.
FAN MOUNTING 3. Slip downrod (A) into yoke, align holes and re-install pin (P) and clip (Q). Tighten set screws and then tighten nuts on the set screws. Slide yoke cover (E) down until it rests on top of motor housing (G). 3 A E Q Set Screws and Nuts Yoke P G 4. Depending on the length of downrod you use, you may need to cut the lead wires back to simplify the wiring. If you decide to cut back the lead wires, it is suggested you do so in the following manner: 4 8 in.
FAN MOUNTING 6. Install hanging ball of downrod (A) into opening of mounting bracket (B). Align the slot in hanging ball with the tab in mounting bracket (B). 6 DANGER: Failure to align slot in hanging ball with the tab in mounting bracket (B) may result in serious injury or death.
WIRING 1b. FAN CONTROLLED BY PULL CHAIN, LIGHT BY WALL SWITCH: If you intend to control the fan light with a separate wall switch, connect BLACK wire from fan to BLACK wire from ceiling. Connect BLUE wire from fan to the BLACK wire from the independent wall switch for the light. Connect WHITE wire from fan to WHITE wire from ceiling. Connect all GROUND (GREEN) wires together from fan (on downrod (A) and mounting bracket (B)) to BARE/GREEN wire from ceiling.
WIRING 3. IMPORTANT: Using a full range dimmer switch (not included) to control fan speed will cause a loud humming noise from fan. To reduce the risk of fire or electrical shock, do NOT use a full range dimmer switch to control fan speed. 3 3 2 1 Dimmer Switch Speed Switch For illustrative purposes only--not intended to cover all types of controls FINAL INSTALLATION 1.
FINAL INSTALLATION 3. Insert two motor screws (R) along with lock washers (S) previously removed (Step 5, page 7) through one blade arm (N) and back into the holes on the underside of motor housing (G). Tighten motor screws (R) securely. Repeat with remaining blade arms (N), making sure to completely secure each blade arm (N) before proceeding with the next. 3 G O S I N R 4. Partially loosen two switch housing screws (U) from outer edge of switch housing plate (H) and remove the other screw.
INSTALLING FAN WITH LIGHT KIT 1. If you wish to use the fan WITH the light kit, connect male plug from motor housing (G) to female plug from switch housing on top of light kit fitter (I), matching up the colors on the male plug with the colors on the female plug for a proper fit. Make sure plugs are connected completely. 1 G I H U Align slotted holes in switch housing at top of light kit fitter (I) with loosened screws in switch housing plate (H).
INSTALLING FAN WITH LIGHT KIT 4. Allow preassembled pull chains to come through light kit fitter (I) slots. Then, align center hole in glass shade (J) with threaded rod, allowing pull chains to come through corresponding holes in glass shade (J). Push up gently on glass shade (J) until threaded rod comes through hole. Secure glass shade (J) with threaded washer (L). CAUTION: Do NOT overtighten threaded washer (L) as glass may crack or break.
INSTALLING FAN WITHOUT LIGHT KIT 2. Firmly place cap (DD) in hole in middle of switch housing. 2 Connect male plug from motor housing (G) to female plug from the switch housing, matching up the colors on the male plug with the colors on the female plug for a proper fit. Make sure plugs are connected completely. Male Plug Female Plug Hardware Used DD Cap x1 DD 3. Align slotted holes in switch housing with loosened switch housing screws (U) in switch housing plate (H).
OPERATING INSTRUCTIONS 1. The pull chain located on the switch housing labeled FOR FAN has four positions to control fan speed. One pull is HIGH, two is MEDIUM, three is LOW and four turns the fan OFF. 1 I X 2. The pull chain located on the switch housing labeled FOR LIGHT has four positions to control light output. One pull turns the UPLIGHT ON, two pulls turns the UPLIGHT OFF and the DOWNLIGHT ON, three pulls turns ALL of the lights ON, and four pulls turns ALL of the lights OFF. 2 I X Lowes.
OPERATING INSTRUCTIONS 3. Use the fan reverse switch, located on the switch housing, to optimize your fan for seasonal performance. A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort. 3 NOTE: Wait for fan to stop before moving the reverse switch. Switch Housing 3A. In warmer weather, setting the reverse switch in the LEFT position will result in downward airflow, creating a wind chill effect.
CARE AND MAINTENANCE At least twice each year, lower canopy (C) to check mounting bracket (B), and then tighten all screws on fan. Clean fan with only a soft brush or lint-free cloth to avoid scratching the finish. Clean blades (O) with a lint-free cloth. You may occasionally apply a light coat of furniture polish to wood blades for added protection. IMPORTANT: Shut off main power supply before beginning any maintenance. Do not use water or a damp cloth to clean the ceiling fan.
TROUBLESHOOTING WARNING: Before beginning work, shut off the power supply to avoid electrical shock. PROBLEM POSSIBLE CAUSE Fan does not move. 1. Reverse switch not engaged. 2. Power is off or fuse is blown. 3. Faulty wire connection. 4. Plugs not connected properly. Noisy operation. CORRECTIVE ACTION 1. Push switch firmly either left or right. 2. Turn power on or check fuse. 3. Turn power off. Loosen canopy and check all connections. 4.
TROUBLESHOOTING PROBLEM Fan operates but light fails. POSSIBLE CAUSE CORRECTIVE ACTION 1. Check wires in canopy and, if 1. Wires in canopy not wired properly. necessary, re-wire according to instructions on pages 9 and 10. 2. Wall switch to fan is off. 2. Make sure that wall switch to fan is on. 3. Plugs not connected properly. 3. Check that male and female plugs in switch housing are connected properly according to instructions on page 13. 4. Light kit is lamped with more than the 4.
REPLACEMENT PARTS LIST For replacement parts, call our customer service department at 1-800-643-0067, 8 a.m. - 6 p.m., EST, Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday. PART A B C H I N O I DESCRIPTION Downrod Mounting Bracket Canopy Switch Housing Plate Light Kit Fitter Blade Arm Blade PART # 747609-A 747609-B 747609-C 747609-H 747609-I 747609-N 747609-O A B H C N O Printed in China Harbor Breeze® is a registered trademark of LF, LLC. All Rights Reserved. Lowes.