Table of contents Safety ......................................................... 2 Maintenance .............................................. 11 Specifications ............................................. 5 Parts List and Diagram .............................. 14 Setup .......................................................... 6 Warranty .................................................... 16 SAFETy WARNING SyMBOLS AND DEFINITIONS This is the safety alert symbol.
. compressor Pump use and care check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the compressor’s operation. If damaged, have the compressor repaired before use. Many accidents are caused by a poorly maintained compressor pump. a. Disconnect the plug of the compressor motor from the power source before installing, making any adjustments, changing accessories, or storing the compressor Pump.
Air compressor Safety Warnings SAFETy 1. Risk of fire or explosion - do not spray flammable liquid in a confined area or towards a hot surface. Spray area must be well-ventilated. Do not smoke while spraying or spray where spark or flame is present. Arcing parts - keep compressor at least 20 feet away from explosive vapors, such as when spraying with a spray gun. 2. Risk of bursting - do not adjust regulator higher than marked maximum pressure of attachment. 3.
TO PREVENT ELEcTRIc SHOcK AND DEATH FROM INcORREcT GROUNDING WIRE cONNEcTION: check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with any motor used with this compressor Pump. Never remove the grounding prong from the plug. Do not use the motor if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use.
Instructions for putting into use Read the ENTIRE IMPORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. SAFETy TO PREVENT SERIOUS INJURy FROM AccIDENTAL OPERATION: Turn the power switch “OFF” and unplug the motor from its electrical outlet before assembling or making any adjustments to the compressor Pump.
Assembly Insert Pump Pulley (59) with this side facing out. crankshaft (51) SAFETy 2. Make sure that the center hole and the keyway on the Pump Pulley (59) are clean and free of burrs and rough edges. 3. Apply a thin layer of grease to the hole and keyway. With the indented side of the Pulley center facing out, align the keyway with the Woodruff Key and slide the Pump Pulley over the Crankshaft. WARNING! Do not force or hammer the Pump Pulley onto the crankshaft. 4.
Installation (continued) 6. Pull the Compressor Pump until properly aligned, and the belt is tight. Recheck the motor pulley, V-belt, and Pump Pulley alignment. SAFETy 7. Use mounting holes in the Compressor Pump base as a template to mark the spots where four holes will be drilled in the mounting surface. 8. Move the Compressor Pump aside and drill four 5/16" diameter holes in the mounting surface. 9.
Item 67697 For technical questions, please call 1-800-444-3353.
A B C D E F G H I J K L M N O B A F Description F G I I J N K Slope J H Function H L L M O For noise and vibration reduction Secures air compressor in place Isolates sections of system for maintenance For vibration reduction Distributes air to branch lines To drain moisture from system Brings air to point of use Connects air to tool Prevents dirt and condensation from damaging tool or workpiece Adjusts air pressure to tool For air tool lubrication Provides quick connection and release Inc
Maintenance and Servicing SAFETy Procedures not specifically explained in this manual must be performed only by a qualified technician. TO PREVENT SERIOUS INJURy FROM AccIDENTAL OPERATION: Turn the power switch “OFF” and unplug the motor from its electrical outlet before performing any inspection, maintenance, or cleaning procedures. TO PREVENT SERIOUS INJURy FROM cOMPRESSOR FAILURE: Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.
Oil Maintenance Check the oil periodically for clarity. Replace oil if it appears milky or if debris is present, or every 6 months, or 100 hours of runtime, whichever comes first. In harsh environments such as high heat or high humidity, you will need to replace the oil more frequently. SAFETy cAUTION! TO PREVENT INJURy FROM BURNS: Allow compressor Pump to cool before changing the oil. 1. Place a container under the Oil Drain Plug. 2. Remove the Oil Fill Plug to allow air flow into the Pump. 3.
Troubleshooting 1. Crankcase oil overfilled or oil too thick. 1. Drain oil and refill to proper level with recommended oil. 2. Working environment too cold. 2. Move compressor to a warmer location. Check that recommended oil is in crankcase. 3. Loose fittings. 3. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten as needed. Do not overtighten. 1. Air filters need cleaning/replacing. 1. Check inlet and outlet filters. Clean and/or replace as needed. 2.
Parts List and Diagram PLEASE READ THE FOLLOWING cAREFULLy SAFETy THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT.
PARTS LIST MAINTENANcE SETUP SAFETy Assembly Diagram Item 67697 For technical questions, please call 1-800-444-3353.
Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.