Product manual
Page 8 For technical questions, please call 1-888-866-5797. ITEM 69747
SAFETY OPERATION MAINTENANCESETUP
Connecting Hoses
Note: Hose coupling components
and hoses not included.
Note: The Suction Hose (not included)
MUST be reinforced with braided material or
have non-collapsible construction. Do not use
a hose with an inside diameter smaller than 1"
(pump’s intake and discharge port diameters).
NOTICE: Do not over-tighten Hose Clamps as the
clamp may damage the hose or other components.
1. Slide one of the Hose Coupling Rings over
one of the Hose Couplers (a), then place a
Gasket on the end of the Hose Coupler (b).
2.
Gasket
Hose Coupler
Hose Coupling Ring
a
b
Thread the Hose Coupling Ring onto
the Intake Port (a), and turn clockwise
until fastened securely (b).
Intake Port
a
b
3. Slide one of the Hose Clamps over the end of the
suction hose (a). Slide the Hose onto the Hose
Coupler (b). Use a screwdriver (not included)
to tighten the Hose Clamp until secure.
CAUTION: Use only a non-collapsible intake hose.
a
b
Hose Clamp
Suction Hose
4. Slide the threaded Hose Coupler onto the Intake
Strainer and thread it securely in place, turning
clockwise (a and b). Slide a Hose Clamp over
the end of the suction hose (c). Slide the Intake
Strainer into the end of the suction hose (d). Use a
screwdriver to tighten the Hose Clamp until secure.
Intake Strainer
a
b