Table of Contents Safety Safety.......................................................... 2 Specifications.............................................. 5 Setup........................................................... 6 Operation..................................................... 8 Maintenance................................................ 9 Parts List and Diagram............................... 11 Warranty.....................................................
. Keep combustible materials and gasses away from the inverter. The inverter produces sparks and heat during operation and can start a fire. 4. Connect to 12 VDC power supply only. A power supply with lower voltage will not operate the Inverter correctly, and higher voltage could damage the unit. 5. Connect input polarity properly. Incorrect connection will damage inverter and void warranty. 6. Do not use in a marine application.
Safety 7. Appliances such as microwave ovens will normally draw more than their rated current. For example: A typical 600 watt microwave oven will draw approximately 1,000 watts. 9. Some fluorescent lamps may not operate properly with this type of inverter. If the bulb appears to be too bright, or fails to light, do not use the lamp with this inverter. 8. Do not attach a battery charger if the charger carries a warning that dangerous voltages are present at the battery terminals. 10.
Output Voltage 115 V~, 60 Hz Continuous Power 2000 Watt Surge Power 4000 Watt Operating Conditions 32° - 104° F AC Receptacles Minimum Battery Cable required (not included) Three 3-prong grounded polarized outlets Eight 30 Amp Internal Blade-type Fuses (professional replacement only) For a 6" cable: 2 AWG or thicker For a 10' cable: 00 AWG or thicker Overall Dimensions 10" L x 9" W x 3-1/2" H Fuse Type Output Waveform Modified Sine Wave (MSW) Sine Wave 1.
Installation Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Safety TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Make sure that the Power Switch is in the off‑position and unplug the tool from its electrical outlet before performing any procedure in this section.
• Charge, store, and maintain batteries according to supplier’s instructions. – d. Connect the negative and positive output cables to opposite ends of the bank. Do not allow the output cables to touch one another. e. Test the voltages at the output cables to help ensure that the battery bank is properly wired.
Operating Instructions Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Safety Tool Set Up TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Make sure that all Power Switches/Triggers is in the off‑position and unplug the tool from its electrical outlet before performing any procedure in this section. Operating Instructions Setup 1. Plug 120 V~ device(s) into the receptacles.
Maintenance and Servicing TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Make sure that all loads are disconnected from the Inverter, the Power Switch is in the off‑position and the cables are disconnected from power source before performing any procedure in this section. Safety Procedures not specifically explained in this manual must be performed only by a qualified technician. To prevent serious injury from tool failure: Do not use damaged equipment.
Troubleshooting Safety Problem Possible Causes Inverter shuts off during use 1. Excessive load at output. 2. Internal temperature is too high. 1. Reduce load to less than rated power. 2. Let the Inverter cool down for at least 30 minutes. Make sure that the fan is not blocked and that the Inverter has sufficient ventilation. No output voltage. 1. Cords not connected properly 2. Fuse on battery bank open 1. Check and secure connections 2. Check battery bank fuse and replace as needed. 3.
Parts List and Diagram Description Plastic Screw M3x12 LED 5.0 LED Cover Switch Screw 2.8x8.0 AC Socket Front Panel Screw M3x6 PCB of Remote PCB of Display Insulation Film Aluminum Housing PCB Qty 2 1 1 1 4 3 1 2 1 1 1 1 1 Part 14 15 16 17 18 19 20 21 22 23 24 25 26 Description Contral Panel Fan 50x50x20 Rear Panel NegativeTerminal Cover Screw M4x8 Positive Terminal Cover Screw 2.8x8.
Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.