Product manual

Page 7SKU 96997 For technical questions, please call 1-800-444-3353.
For best tool performance, you should incorporate an oiler, regulator, and in-2.
line water lter as shown in the illustration below. If an oiler is NOT used, it is
recommended that you squirt 3 to 4 drops of pneumatic tool oil (not included) into
the previously installed Quick Connector of the tool before each use.
(See Figure B.)
SET UP INSTRUCTIONS
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the
beginning of this manual including all text under subheadings therein
before set up or use of this product.
Risk of accidental starting; resulting in serious personal
injury. Disconnect the Sander from its compressed air
source before assembling or making any adjustments to the
tool.
Note: For additional information regarding the parts listed in the following pages, refer
to the Assembly Diagram near the end of this manual.
Assembly
Prior to using the Sander, the Scaler must have a male Quick Connector (not 1.
included) connected to the tool’s Air Inlet (20). To do so, wrap about 3” of Pipe
Thread Seal Tape (not included) around the threads of the Quick Connector.
Then rmly screw on the Quick Connector. (See Figure A.)
WARNING
FIGURE A
QUICK CONNECTOR
(NOT INCLUDED)
TO
SCALER
OILER FILTER
REGULATOR
AIR
COMPRESSOR
FIGURE B