ELECTRIC PORTABLE PIPE THREADER Model 93880 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. ® 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE. © Copyright 2006 by Harbor Freight Tools®. All rights reserved.
PRODUCT SPECIFICATIONS Motor 110 VAC / 60 Hz / 1700 W / 20 RPM @ the Die (Reversible) 20.6 AMP (Star t-No Load) / 6.6 AMP (Run-No Load) Accessible Motor Brushes Power Cord 10' Long, 2-Prong Plug Die (Par t #54): Threading Capacity 1/ " 2 3/ " 4 1" 11/4" SAVE THIS MANUAL You will need this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. Keep your invoice with this manual.
grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. If the tools should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user. 5. Double insulated tools are equipped with a polarized plug (one blade is wider than the other).
footing and balance enables better control of this product in unexpected situations. 14. Use safety equipment. Wear eye protection when assembling this product. Nonskid safety shoes must be used for appropriate conditions. TOOL USE AND CARE 15. Disconnect the Power Cord Plug from the power source before making any adjustments, changing accessories, or storing the Pipe Threader. Such preventive safety measures reduce the risk of starting the unit accidentally. 16.
3. Maintain a safe environment. Keep the area well lit. Make sure there is adequate surrounding space. Always keep the area free of obstructions, grease, oil, trash, and other debris. Do not use an electrically powered product in areas near flammable chemicals, dusts, and vapors. 4. Never leave the Pipe Threader unattended when it is plugged into an electrical outlet. Turn off the Pipe Threader and unplug the tool before leaving. 5.
GROUNDING WARNING! Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by service facility before use.
DOUBLE INSULATED TOOLS: TOOLS WITH TWO PRONG PLUGS 4. Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Figure B.) 5. Double insulated tools may be used in either of the 120 volt outlets shown in the following illustration. (See Figure B.
6. If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use. 7. Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it. 8. Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
ASSEMBLY AND OPERATING INSTRUCTIONS NOTE: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagrams on pages 15 and 16. 1. CAUTION! Always make sure the Pipe Threader is disconnected from its electrical outlet prior to assembling the tool, changing accessories, or performing service to the product. 2. Wear ANSI-approved safety impact eye goggles and heavy duty work gloves when using the Pipe Threader.
7. Insert the pipe into the rear of the Die (54, 54A, 54B, 54C). Make sure the inside diameter of the Die matches the outside diameter of the pipe. (See Figure F.) FIGURE F 8. CAUTION! Always use the Pipe Clamp assembly (56, 57, 58) to secure and support the pipe during the threading operation. Make sure the Pipe Clamp assembly (56, 57, 58) is securely clamping the pipe and that the pipe is well supported while the threads are being cut. (See Figure G.
. Connect the Power Cord Plug (49) into the nearest 110 volt, grounded, electrical outlet. 12. While holding the Handle (40, 46) with one hand, press the Power Switch (42) in and pull up on it to turn on the Pipe Threader. Apply pressure until the Die (54, 54A, 54B, 54C) engages the pipe, cutting two to three threads. (See Figure H.) ROTATING DIRECTION SWITCH (41) POWER SWITCH (42) FIGURE H 13.
INSPECTION, MAINTENANCE, AND CLEANING 1. WARNING! Make sure the Pipe Threader is disconnected from its electrical outlet prior to performing any inspection, maintenance, or cleaning procedures. 2. Before each use, inspect the general condition of the Pipe Threader. Check for cracked or broken parts, damaged electrical wiring, damaged Die Blades, and any other condition that may affect safe operation. If abnormal noise or vibration occurs, have the problem corrected before further use.
four new Die Blades into the Die. NOTE: When inserting the Die Blades, make sure the cutting edges of the Die Blades face inward. Also, make sure the number on each Die Blade is at the top and in sequence. Once the Die Blades are properly inserted, replace the Chrome Ring and four Screws. (See Figure J.) TOP VIEW DIE (54, 54A, 54B, 54C) 1 CHROME RING 2 SCREWS MAKE SURE NUMBERS ARE ON TOP AND IN SEQUENCE 4 3 DIE BLADE (55, 55A, 55B, 55C) FIGURE J 5.
PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER.
ASSEMBLY DIAGRAM NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts.
ASSEMBLY DIAGRAM (CONT.) NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts.
LIMITED 90 DAY WARRANTY Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser for a period of ninety days from date of purchase that the motor, the belts, and the blades are free of defects in materials and workmanship. This warranty does not apply to damage due directly or indirectly to misuse, abuse, negligence or accidents; repairs or alterations outside our facilities; or to lack of maintenance.