Product manual

Page 10 For technical questions, please call 1-888-866-5797. Item 62203
SAFETY OPERATION MAINTENANCESETUP
Workpiece and Work Area Set Up
1. Designate a work area that is clean and well lit.
The work area must not allow access by children
or pets to prevent distraction and injury.
2. Route power cord along a safe route to reach
the work area without creating a tripping hazard
or exposing the power cord to possible damage.
Power cord must reach the work area with enough
extra length to allow free movement while working.
3. There must not be objects, such as utility lines,
nearby that will present a hazard while working.
4. Use Clamp assembly to secure and support
pipe during threading operation. Screw Clamp
Rod into Clamp. Make sure pipe is secured
to Clamp assembly and is supported during
threading operation. (See Figure B.)
Figure B
5. Install Clamp Rod into Clamp Rob Slot. Ensure
Clamp Lever can be adjusted easily from above. Be
certain that pipe has enough clearance to proceed.
Note: Pipe end to be threaded must
be clean and chamfered.
6. Insert pipe into toothless end of Die.
Make sure inside diameter of Die matches
outside diameter of pipe. (See Figure C.)
Die
Pipe
Clamp
Rod
Clamp
Rod Slot
Figure C