User guide
HI 1746-WS WEIGH SCALE MODULE
4-14
Error Return Values:
• STATUSWORD - there was a conversion error,
weig
ht in motion or an A/D error or all three.
• C2FAILNODEVS - did not detect any C2 load
cells.
• C2FAILCAPEQ - detected two load cells with
dif
ferent capacities.
SEQ
NUMBER
0
COMMAND#
(Hex)
1
STATUS
2
OFFSET
3
LENGTH
4
DATA
5-16
From M1 File 0x66
Read C2 Serial
Number Command
(READC2SERIALN
UM)
The Read C2 Serial Number Command - Reads the 9
byte
serial number from a C2 chip located on every
C2 load cell. Specify the index of the C2 chip to read
in commandData.offset of the Mfile. The index
should be a number of 0 to C2RomX-1 (-1 is a minus
one not a dash one), where C2RomX is the number of
C2 chips. The “serial number” will be 8 bytes of
ASCII text, followed by a 0 terminator.
Error Return Values:
• OUTOFTOLERANCE - specified chip is not
fo
und.
SEQ
NUMBER
0
COMMAND#
(Hex)
1
STATUS
2
OFFSET
3
LENGTH
4
DATA
5-16
From M1 File 0x70
Set Parameters
Command
(SETPARAM)
Sets a parameter in the module. (See Setting the Pro-
cess Weighing Parameters below for more detailed
information.)