User guide

HI 1746-WS WEIGH SCALE MODULE
6-2
6 Setpoint 1 Mode
Bit Setpoint Mode
0 ROC (Rate of Change)
1Gross
2Net
3 Gain Mode (0 = gain in wght)
(1 = loss in wght)
4 force low
5 force high
6 Excitation Error
7 No Excitation Error
8-15 Currently Not Used
7 Setpoint 2
Value (32 bit float, or integer)
MSW
8 Setpoint 2
Value (32 bit float, or integer)
LSW
9 Setpoint 2
Deadband (32 bit float, or integer)
MSW
10 Setpoint 2
Deadband (32 bit float, or integer)
LSW
11 Setpoint 2
Preact (32 bit float, or integer)
MSW
12 Setpoint 2
Preact (32 bit float, or integer)
LSW
WORD PARAMETER
TABLE 6-1: BLOCK TRANSFER, READ