Manual

HI 1769-WS/HI 1769-2WS WEIGH SCALE MODULE
4-2
FIG. 4-2 MODULE LEDS HI 1769-2WS DUAL
CHANNEL
LEDS The module has a Scale LED and an OK LED associ-
ated with it. The LEDs may be green, red or off. They
may be steady, Fast Flashing (5 Hertz) of Slow Flash
-
ing (1 Hertz)
Scale Data
LEDs
Steady Green Running (Normal)
Slow Flashing Green Error No Calibration
Steady Red Error ERRORADFAILURE -
(hardware induced) status bit is
set.
Flashing Red Read AD Convert Error.
LED is Off Channel is not Enabled
OK Module
Status LED
Fast Flashing Green Module communicating with
PLC. (Normal)
Slow Flashing Red Module is not Communicating
with the PLC (Not Normal)
Error, configuration/error in
PLC addressing
NOTE: Slow Flashing Red appears briefly when powering up.
NOTE: *Contact Hardy Customer Support for assistance.